Integration accuracy of craniofacial cone-beam computed tomography images with three-dimensional facial scans according to different registration areas

被引:3
作者
Aljawad, Hussein [1 ]
Kang, Nara [2 ]
Lee, Kyungmin Clara [3 ,4 ]
机构
[1] Chonnam Natl Univ, Sch Dent, Dept Orthodont, Gwangju, South Korea
[2] Sun Dent Hosp, Dept Oral & Maxillofacial Surg, Div Jaw Surg & Sleep Surg, Daejeon, South Korea
[3] Chonnam Natl Univ, Sch Dent, Dept Orthodont, Gwangju, South Korea
[4] Chonnam Natl Univ, Sch Dent, Dept Orthodont, 33 Yongbong Ro, Gwangju 61186, South Korea
关键词
Integration; Registration; CBCT; Facial scan; RAPID MAXILLARY EXPANSION; RELIABILITY;
D O I
10.2319/021422-135.1
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: To evaluate the integration accuracy of cone-beam computed tomography (CBCT) images with three-dimensional (3D) facial scans according to different registration areas.Materials and Methods: Twenty-five patients (14 males and 11 females), with a mean age of 19.0 6 11.3 years, were included in this study. Each patient underwent CBCT and facial scans on the same day in an upright position. The facial scans were integrated with the corresponding soft-tissue images of CBCT scans. Three methods were used to integrate the two imaging modalities based on the facial regions scanned: R1, only the forehead and nasal bridge area were included; R2, the right and left malar area were included; and R3, the forehead, nasal bridge, and malar areas were included. The integration accuracy between the facial scans and CBCT images was evaluated by color-mapping methods and average surface distances, calculated by measuring the 3D distances between the surface points on the two superimposed images.Results: The average surface differences between facial scans and CBCT images were less than 1.0 mm in all three methods. The R3 method showed fewer differences between the facial scans and CBCT images than the other methods did.Conclusions: Facial scans obtained using a low-cost facial scanner showed clinically acceptable performance. The integration accuracy of facial and CBCT scans can be increased by including the forehead, nasal bridge, and malar areas as registration areas. (Angle Orthod. 2022;93:66-70.)
引用
收藏
页码:66 / 70
页数:5
相关论文
共 21 条
  • [11] Registration of 3-Dimensional Facial Photographs for Clinical Use
    Maal, Thomas J. J.
    van Loon, Bram
    Plooij, Joanneke M.
    Rangel, Frits
    Ettema, Anke M.
    Borstlap, Wilfred A.
    Berge, Stefaan J.
    [J]. JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2010, 68 (10) : 2391 - 2401
  • [12] Evaluation of the accuracy of a mobile and a stationary system for three-dimensional facial scanning
    Modabber, Ali
    Peters, Florian
    Kniha, Kristian
    Goloborodko, Evgeny
    Ghassemi, Alireza
    Lethaus, Bernd
    Hoelzle, Frank
    Moehlhenrich, Stephan Christian
    [J]. JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2016, 44 (10) : 1719 - 1724
  • [13] Fusion of computed tomography data and optical 3D images of the dentition for streak artefact correction in the simulation of orthognathic surgery
    Nkenke, E
    Zachow, S
    Benz, M
    Maier, T
    Veit, K
    Kramer, M
    Benz, S
    Häusler, G
    Neukam, FW
    Lell, M
    [J]. DENTOMAXILLOFACIAL RADIOLOGY, 2004, 33 (04) : 226 - 232
  • [14] Registration accuracy in the integration of laser-scanned dental images into maxillofacial cone-beam computed tomography images
    Noh, Hoon
    Nabha, Wael
    Cho, Jin-Hyoung
    Hwang, Hyeon-Shik
    [J]. AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2011, 140 (04) : 585 - 591
  • [15] Method selection in craniofacial measurements: Advantages and disadvantages of 3D digitization method
    Ozsoy, Umut
    Demirel, Bahadir Murat
    Yildirim, Fatos B.
    Tosun, Ozgur
    Sarikcioglu, Levent
    [J]. JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2009, 37 (05) : 285 - 290
  • [16] Three-dimensional scanners for soft-tissue facial assessment in clinical practice
    Petrides, George
    Clark, JonathAn R.
    Low, Hubert
    Lovell, Nigel
    Eviston, Timothy J.
    [J]. JOURNAL OF PLASTIC RECONSTRUCTIVE AND AESTHETIC SURGERY, 2021, 74 (03) : 605 - 614
  • [17] Premjani Pratik, 2015, J Clin Orthod, V49, P641
  • [18] Registration area and accuracy when integrating laser-scanned and maxillofacial cone-beam computed tomography images
    Sun, LiJun
    Hwang, Hyeon-Shik
    Lee, Kyung-Min
    [J]. AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2018, 153 (03) : 355 - 361
  • [19] 3D Stereophotogrammetric assessment of pre- and postoperative volumetric changes in the cleft lip and palate nose
    van Loon, B.
    Maal, T. J.
    Plooij, J. M.
    Ingels, K. J.
    Borstlap, W. A.
    Kuijpers-Jagtman, A. M.
    Spauwen, P. H.
    Berge, S. J.
    [J]. INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2010, 39 (06) : 534 - 540
  • [20] Integration of digital maxillary dental casts with 3D facial images in orthodontic patients: A three-dimensional validation study
    Xiao, Zhuoxing
    Liu, Zijin
    Gu, Yan
    [J]. ANGLE ORTHODONTIST, 2020, 90 (03) : 397 - 404