Effect of routine suction on lung aeration in critically ill neonates and young infants measured with electrical impedance tomography

被引:1
作者
Haendel, Claas [1 ]
Becher, Tobias [1 ]
Miedema, Martijn [2 ,3 ,4 ]
Kallio, Merja
Papadouri, Thalia [5 ]
Waldmann, Andreas D. [6 ]
Sophocleous, Louiza [7 ]
Karaoli, Christina [5 ]
Yerworth, Rebecca [8 ]
Bayford, Richard [9 ]
Rimensberger, Peter C. [10 ]
van Kaam, Anton H. [2 ]
Frerichs, Inez [1 ]
机构
[1] Univ Med Ctr Schlewig Holstein, Dept Anaesthesiol & Intens Care Med, Campus Kiel, Kiel, Germany
[2] Amsterdam Reprod & Dev Res Inst, Amsterdam, Netherlands
[3] Oulu Univ Hosp, Dept Pediat & Adolescent Med, Oulu, Finland
[4] Univ Oulu, Res Unit Clin Med, Oulu, Finland
[5] Arch Makarios III Hosp, Neonatal Intens Care Unit, Nicosia, Cyprus
[6] Univ Med Ctr Rostock, Dept Anesthesiol & Intens Care Med, Rostock, Germany
[7] Univ Cyprus, Dept Elect & Comp Engn, KIOS Res Ctr, Nicosia, Cyprus
[8] UCL, Med Phys & Biomed Engn Dept, London, England
[9] Middlesex Univ, Dept Nat Sci, London, England
[10] Univ Geneva, Univ Hosp Geneva, Div Neonatol & Pediat Intens Care, Geneva, Switzerland
基金
欧盟地平线“2020”;
关键词
ENDOTRACHEAL SUCTION; TIME CONSTANTS; RECRUITMENT; VENTILATION;
D O I
10.1038/s41598-023-42965-7
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Endotracheal suctioning is a widely used procedure to remove secretions from the airways of ventilated patients. Despite its prevalence, regional effects of this maneuver have seldom been studied. In this study, we explore its effects on regional lung aeration in neonates and young infants using electrical impedance tomography (EIT) as part of the large EU-funded multicenter observational study CRADL. 200 neonates and young infants in intensive care units were monitored with EIT for up to 72 h. EIT parameters were calculated to detect changes in ventilation distribution, ventilation inhomogeneity and ventilation quantity on a breath-by-breath level 5-10 min before and after suctioning. The intratidal change in aeration over time was investigated by means of regional expiratory time constants calculated from all respiratory cycles using an innovative procedure and visualized by 2D maps of the thoracic cross-section. 344 tracheal suctioning events from 51 patients could be analyzed. They showed no or very small changes of EIT parameters, with a dorsal shift of the center of ventilation by 0.5% of the chest diameter and a 7% decrease of tidal impedance variation after suctioning. Regional time constants did not change significantly. Routine suctioning led to EIT-detectable but merely small changes of the ventilation distribution in this study population. While still a measure requiring further study, the time constant maps may help clinicians interpret ventilation mechanics in specific cases.
引用
收藏
页数:9
相关论文
共 23 条
  • [1] Uses and abuses of EIDORS: an extensible software base for EIT
    Adler, A
    Lionheart, WRB
    [J]. PHYSIOLOGICAL MEASUREMENT, 2006, 27 (05) : S25 - S42
  • [2] GREIT: a unified approach to 2D linear EIT reconstruction of lung images
    Adler, Andy
    Arnold, John H.
    Bayford, Richard
    Borsic, Andrea
    Brown, Brian
    Dixon, Paul
    Faes, Theo J. C.
    Frerichs, Inez
    Gagnon, Herve
    Gaerber, Yvo
    Grychtol, Bartlomiej
    Hahn, Guenter
    Lionheart, William R. B.
    Malik, Anjum
    Patterson, Robert P.
    Stocks, Janet
    Tizzard, Andrew
    Weiler, Norbert
    Wolf, Gerhard K.
    [J]. PHYSIOLOGICAL MEASUREMENT, 2009, 30 (06) : S35 - S55
  • [3] [Anonymous], 2012, Appl. Cardiopulm. Pathophysiol
  • [4] Characteristic pattern of pleural effusion in electrical impedance tomography images of critically ill patients
    Becher, T.
    Bussmeyer, M.
    Lautenschlaeger, I.
    Schaedler, D.
    Weiler, N.
    Frerichs, I.
    [J]. BRITISH JOURNAL OF ANAESTHESIA, 2018, 120 (06) : 1219 - 1228
  • [5] Functional Regions of Interest in Electrical Impedance Tomography: A Secondary Analysis of Two Clinical Studies
    Becher, Tobias
    Vogt, Barbara
    Kott, Matthias
    Schaedler, Dirk
    Weiler, Norbert
    Frerichs, Inez
    [J]. PLOS ONE, 2016, 11 (03):
  • [6] Prolonged Continuous Monitoring of Regional Lung Function in Infants with Respiratory Failure
    Becher, Tobias H.
    Miedema, Martijn
    Kallio, Merja
    Papadouri, Thalia
    Karaoli, Christina
    Sophocleous, Louiza
    Rahtu, Marika
    van Leuteren, Ruud W.
    Waldmann, Andreas D.
    Strodthoff, Claas
    Yerworth, Rebecca
    Dupre, Antoine
    Benissa, Mohamed-Rida
    Nordebo, Sven
    Khodadad, Davood
    Bayford, Richard
    Vliegenthart, Roseanne
    Rimensberger, Peter C.
    van Kaam, Anton H.
    Frerichs, Inez
    [J]. ANNALS OF THE AMERICAN THORACIC SOCIETY, 2022, 19 (06) : 991 - 999
  • [7] End-expiratory lung volume recovers more slowly after closed endotracheal suctioning than after open suctioning: A randomized crossover study
    Corley, Amanda
    Spooner, Amy J.
    Barnett, Adrian G.
    Caruana, Lawrence R.
    Hammond, Naomi E.
    Fraser, John F.
    [J]. JOURNAL OF CRITICAL CARE, 2012, 27 (06) : 742.e1 - 742.e7
  • [8] Chest electrical impedance tomography measures in neonatology and paediatrics-a survey on clinical usefulness
    Frerichs, Inez
    Becher, Tobias
    [J]. PHYSIOLOGICAL MEASUREMENT, 2019, 40 (05)
  • [9] Chest electrical impedance tomography examination, data analysis, terminology, clinical use and recommendations: consensus statement of the TRanslational EIT developmeNt stuDy group
    Frerichs, Inez
    Amato, Marcelo B. P.
    van Kaam, Anton H.
    Tingay, David G.
    Zhao, Zhanqi
    Grychtol, Bartlomiej
    Bodenstein, Marc
    Gagnon, Herve
    Bohm, Stephan H.
    Teschner, Eckhard
    Stenqvist, Ola
    Mauri, Tommaso
    Torsani, Vinicius
    Camporota, Luigi
    Schibler, Andreas
    Wolf, Gerhard K.
    Gommers, Diederik
    Leonhardt, Steffen
    Adler, Andy
    [J]. THORAX, 2017, 72 (01) : 83 - 93
  • [10] Lung recruitment and endotracheal suction in ventilated preterm infants measured with electrical impedance tomography
    Hough, Judith L.
    Shearman, Andrew D.
    Liley, Helen
    Grant, Caroline A.
    Schibler, Andreas
    [J]. JOURNAL OF PAEDIATRICS AND CHILD HEALTH, 2014, 50 (11) : 884 - 889