Experimental and Numerical Investigation of the Effect of Water Cooling on the Temperature Distribution of Photovoltaic Modules Using Copper Pipes

被引:4
作者
Shojaeefard, Mohammad Hassan [1 ]
Sakran, Noor Barzan [1 ,2 ]
Sharfabadi, Mohammad Mazidi [3 ]
Hussein, Omar A. [4 ]
Mohammed, Hussein A. [5 ]
机构
[1] Iran Univ Sci & Technol IUST, Sch Mech Engn, Tehran 1311416846, Iran
[2] Fdn Martyrs, Presidency Ministers, Nassiriya 64001, Thi Qar, Iraq
[3] Res Inst Petr Ind RIPI, Dev & Optimizat Energy Technol Div, Tehran 13111, Iran
[4] Tikrit Univ, Coll Petr Proc Engn, Petr Syst Control Engn Dept, Tikrit 34001, Iraq
[5] Edith Cowan Univ, Sch Engn, 270 Joondalup Dr, Joondalup, WA 6027, Australia
关键词
solar thermal; thermal-photovoltaic hybrid collector; thermal modeling; electrical and thermal efficiency; solar thermoelectric cooler; PERFORMANCE EVALUATION; HEAT-TRANSFER; SOLAR; EFFICIENCY; CHANNEL; SYSTEM; CELLS;
D O I
10.3390/en16104102
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In hot climates, PV efficiency drops dramatically if the surface temperature of the panels rises over a specific limit. Consequently, a cooling system is required to preserve PV modules as close to their operating temperature as feasible. For this purpose, the influence of an increase in PV surface temperature on PV performance was studied experimentally and numerically at the Research Institute of Petroleum Industry (RIPI) in July. The current study uses a cooling system consisting of rows of copper pipes connected to the PV backside. The experiments are conducted for four distinct scenarios, each with a different input fluid temperature ranging from 19.5 to 61 degrees C. The parametric analysis focuses on three influential factors: ambient temperature, solar radiation, and fluid inlet temperatures. In addition, other inputs are configured in accordance with the experimental conditions. The results showed that installing a cooling water system decreased the PV surface temperature from 60.20 degrees C to 40.24 degrees C at 9:00 am and from 73.98 degrees C to 73.33 degrees C at 1:30 pm. Furthermore, the electrical, thermal, overall, and exergy efficiencies drop as radiation intensity and water inlet temperature increase. In addition, the numerical results are validated with the experimental ones, and it shows high degrees of concordance.
引用
收藏
页数:21
相关论文
共 50 条
  • [31] Experimental and numerical assessments of a photovoltaic thermal collector equipped with newly configured cooling methods using PCM/CFM
    Dayer, Mojtaba
    Shahid, Muhammad Ashhad
    Sopian, Kamaruzzaman
    Kazem, Hussein A.
    Al-Aasam, Anwer Basim
    Abdulsahib, Bassam
    Al-Waeli, Ali H. A.
    SOLAR ENERGY, 2024, 276
  • [32] Experimental investigation of cooling photovoltaic (PV) panels using (TiO2) nanofluid in water -polyethylene glycol mixture and (Al2O3) nanofluid in water- cetyltrimethylammonium bromide mixture
    Ebaid, Munzer. S. Y.
    Ghrair, Ayoup. M.
    Al-Busoul, Mamdoh
    ENERGY CONVERSION AND MANAGEMENT, 2018, 155 : 324 - 343
  • [33] Effect of dual surface cooling of solar photovoltaic panel on the efficiency of the module: experimental investigation
    Agyekum, Ephraim Bonah
    PraveenKumar, Seepana
    Alwan, Naseer T.
    Velkin, Vladimir Ivanovich
    Shcheklein, Sergey E.
    HELIYON, 2021, 7 (09)
  • [34] Numerical investigation of the effect of radiator placement on temperature distribution in a room
    Ufat, Hande
    PROGRESS IN COMPUTATIONAL FLUID DYNAMICS, 2024, 24 (06): : 367 - 376
  • [35] Experimental investigation on the effect of photovoltaic panel partially and fully submerged in water
    Madhu, Balasubramanian
    Balasubramanian, Esakki
    Kabeel, Abd Elnaby
    Sathyamurthy, Ravishankar
    El-Agouz, El-Sayed
    Manokar, Athikesavan Muthu
    HEAT TRANSFER-ASIAN RESEARCH, 2019, 48 (05): : 1709 - 1721
  • [36] Experimental investigation of using the evaporative air cooling technique to enhance the performance of the photovoltaic module
    Jaffar, Malik F.
    Mohammad, Abdulrahman Th
    Ahmed, Ahmed Qasim
    Al-Shohani, Wisam A. M.
    INTERNATIONAL JOURNAL OF LOW-CARBON TECHNOLOGIES, 2024, 19 : 1231 - 1245
  • [37] Experimental study on the electrical and thermal characteristics of a hybrid photovoltaic/thermal water solar collector model using photovoltaic solar modules of different brands
    Alexis, Lontsi Kuefouet
    Kewir, Tangka Julius
    Merlain, Djousse Kanouo Boris
    Bertholt, Sogang Segning Harry
    ENERGY CONVERSION AND MANAGEMENT-X, 2022, 14
  • [38] Comparative investigation on the cooling effect of swirling impinging jetusing experimental and numerical methods
    Jie-min, Zhou
    Yi-feng, Fu
    Ying, Yang
    Juan, Tu
    Bing-ting, Hu
    Xiao-ling, Chen
    HDP'07: PROCEEDINGS OF THE 2007 INTERNATIONAL SYMPOSIUM ON HIGH DENSITY PACKAGING AND MICROSYSTEM INTEGRATION, 2007, : 245 - +
  • [39] Experimental and CFD investigation on temperature distribution of a serpentine tube type photovoltaic/thermal collector
    Zhou, Jicheng
    Ke, Haoyun
    Deng, Xiaoqing
    SOLAR ENERGY, 2018, 174 : 735 - 742
  • [40] Numerical investigation on using of nanofluid in a water-cooled photovoltaic thermal system
    Khanjari, Y.
    Pourfayaz, F.
    Kasaeian, A. B.
    ENERGY CONVERSION AND MANAGEMENT, 2016, 122 : 263 - 278