Effect evaluation on performance issues of passive safety system-Part I. Passive heat removal system

被引:6
作者
Lee, Jeehee [1 ,3 ]
Jeon, Seong-Su [1 ]
Park, Ju-Yeop [2 ]
Cho, Hyoung Kyu [3 ]
机构
[1] FNC Technol Co Ltd, 13 Heungdeok 1 ro, Yongin 16954, Gyounggi Do, South Korea
[2] Korea Inst Nucl Safety, 62 Kwahak ro, Daejeon Si 34142, South Korea
[3] Seoul Natl Univ, Dept Nucl Engn, 1 Gwanak ro, Seoul 08826, South Korea
关键词
Passive safety system; Natural circulation; Thermal -hydraulic code; Performance evaluation; Passive heat removal system; IN-TUBE CONDENSATION; RELIABILITY EVALUATION; FLOW; MODELS;
D O I
10.1016/j.nucengdes.2023.112160
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The passive safety system has advantages over active safety system since it has low dependence on the operator and external power supply. However, because the passive safety system operates with natural phenomena such as gravity, density difference, pressure difference, etc., the driving force is very low compared with active safety system. Therefore, the change of the internal/external environment of the system can have an effect on the performance of system. For this reason, it is necessary to evaluate whether the system can sufficiently perform the safety function in various accident situations. Since the existing safety standards for safety system have been developed for active safety systems, it is required to develop standards for performance evaluation of passive safety systems. For this reason, in this study, performance evaluation method for passive safety system is being developed. Since the identifying major performance issues is important for developing methodology, performance issues that can affect the natural circulation flow of the system, such as friction and heat loss of pipe within the system, are investigated and selected through the research related to safety regulation of passive safety systems. The effect of each performance issue on the system has analyzed by using conceptual problem for PHRS type passive safety system. For the effect analysis, passive safety systems using single/two phase natural circulation flow are conceptually designed by referring to the concept of the existing systems. For the effect evaluation, MARS-KS, which is system analysis code developed by KAERI, is used in this study. The main conclusions on the effect of each performance issues are drawn through the analysis. In addition, after the individual effect analysis of performance issues on passive safety system, a comprehensive assessment has performed to analyze the performance of system when several issues acted simultaneously.
引用
收藏
页数:22
相关论文
共 50 条
[41]   Reliability assessment of passive residual heat removal system using FORM methodology with chaos control [J].
Zhang, Shiqi ;
Xia, Genglei ;
Peng, Minjun ;
Wang, Chenyang .
ANNALS OF NUCLEAR ENERGY, 2023, 184
[42]   Numerical study on improved design of passive residual heat removal system for China pressurizer reactor [J].
Li, Yongquan ;
Song, Ping ;
Feng, Tangtao ;
Wang, Mingjun ;
Zhang, Dalin ;
Tian, Wenxi ;
Qiu, Suizheng .
NUCLEAR ENGINEERING AND DESIGN, 2021, 375
[43]   INVESTIGATION OF REVERSE FLOW IN THE PASSIVE RESIDUAL HEAT REMOVAL SYSTEM OF NHR-200II [J].
Geng Yiwa ;
Li Ziyi ;
Liu Xiongbin ;
Huang Shuliang ;
Qin Haiqi .
PROCEEDINGS OF 2024 31ST INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING, VOL 6, ICONE31 2024, 2024,
[44]   Assessment of passive safety system performance under main steam line break accident [J].
Lim, J. ;
Choi, S. W. ;
Yang, J. ;
Lee, D. Y. ;
Rassame, S. ;
Hibiki, T. ;
Ishii, M. .
ANNALS OF NUCLEAR ENERGY, 2014, 64 :287-294
[45]   Assessment of passive safety system performance under gravity driven cooling system drain line break accident [J].
Lim, J. ;
Yang, J. ;
Choi, S. W. ;
Lee, D. Y. ;
Rassame, S. ;
Hibiki, T. ;
Ishii, M. .
PROGRESS IN NUCLEAR ENERGY, 2014, 74 :136-142
[46]   Comparison research on numerical modeling methods for the passive heat removal system of fast reactors based on PLANDTL benchmark experiment [J].
Song, Haijie ;
Zhang, Yuhao ;
Zhao, Haiqi ;
Sui, Danting ;
Lu, Daogang .
ANNALS OF NUCLEAR ENERGY, 2025, 212
[47]   ASSESSMENT OF CONDENSATION HEAT TRANSFER MODEL TO EVALUATE PERFORMANCE OF THE PASSIVE AUXILIARY FEEDWATER SYSTEM [J].
Cho, Yun-Je ;
Kim, Seok ;
Bae, Byoung-Uhn ;
Park, Yusun ;
Kang, Kyoung-Ho ;
Yun, Byong-Jo .
NUCLEAR ENGINEERING AND TECHNOLOGY, 2013, 45 (06) :759-766
[48]   Experimental study on heat transfer performance between fluoride salt and heat pipes in the new conceptual passive residual heat removal system of molten salt reactor [J].
Liu, Minghao ;
Zhang, Dalin ;
Wang, Chenglong ;
Qiu, Suizheng ;
Su, G. H. ;
Tian, Wenxi .
NUCLEAR ENGINEERING AND DESIGN, 2018, 339 :215-224
[49]   Flow organization around heat exchanger tube and its influence on heat exchange capability in passive residual heat removal system [J].
Song, Yu ;
Zhao, Jia-Qing ;
Li, Xiao-Wei ;
Li, Xiao-Tian ;
Wu, Xin-Xin .
Yuanzineng Kexue Jishu/Atomic Energy Science and Technology, 2015, 49 (11) :2004-2010
[50]   Experiments on the heat transfer and natural circulation characteristics of the passive residual heat removal system for an advanced integral type reactor [J].
Park, Hyun-Sik ;
Choi, Ki-Yong ;
Cho, Seok ;
Park, Choon-Kyung ;
Yi, Sung-Jae ;
Song, Chu-Hwa ;
Chung, Moon-Ki .
JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 2007, 44 (05) :703-713