Influence of surface coatings on the stress distribution by varying friction contact at implant-bone interface using finite element analysis

被引:3
作者
Dhatrak, Pankaj [1 ,2 ]
Kurup, Alekh [1 ]
Khasnis, Neha [1 ]
机构
[1] Dr Vishwanath Karad MIT World Peace Univ, MIT Pune, Pune, Maharashtra, India
[2] Dr Vishwanath Karad MIT World Peace Univ, S 124,Paud Rd, Pune 411038, Maharashtra, India
关键词
Dental implant; FEA; friction coefficient; stress distribution; surface coatings; DENTAL IMPLANTS; CORROSION-RESISTANCE; TITANIUM-ALLOY; STABILITY; BIOCOMPATIBILITY; ANTIBACTERIAL; MORPHOLOGY; SUBSTRATE; DESIGN; MODEL;
D O I
10.1177/09544119221146617
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The present work aims to evaluate the effect of various surface coatings of titanium dental implants by varying the friction coefficient (mu) at the interface between the dental implant and jawbone using finite element analysis (FEA) methods and to provide a comparative analysis between the various surface coatings and implant designs. An accurate model of the dental implant prosthetics consisting of the hard (cortical) and the soft (cancellous) bone, with the various titanium dental implant designs was modelled using a 3D CAD software, and the FE mesh model was generated using HyperMesh 13.0. Three coatings having different coefficient of friction values were selected: Titanium Nitride (TiN) with a friction coefficient of 0.19, Titanium Oxide (TiO2) with a friction coefficient of 0.30 and Zirconium Nitride (ZrN) with a coefficient of friction of 0.49. The non-linear static stress analysis was conducted under three different loading conditions (vertical, lateral and oblique loading) using a CAE solver. The present study showed that surface coatings with high friction coefficients generated lower stresses in the cancellous bone while generating higher stresses in the cortical bone. However, for dental implants having microthreads in their neck region, surface coatings with a high coefficient of friction generated lower stresses at the interface between the cortical bone and the implant. The FEA results indicate that selecting suitable surface coatings would significantly decrease the stresses developed at the bone-implant interface, and future studies should conduct in vivo trials to validate the FEA results obtained.
引用
收藏
页码:233 / 242
页数:10
相关论文
共 50 条
  • [1] Effect of microthread design of dental implants on stress and strain patterns: a three-dimensional finite element analysis
    Amid, Reza
    Raoofi, Saeed
    Kadkhodazadeh, Mahdi
    Movahhedi, Mohammad Reza
    Khademi, Maryam
    [J]. BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2013, 58 (05): : 457 - 467
  • [2] Effect of surface treatment on stress distribution in immediately loaded dental implants-A 3D finite element analysis
    Bahrami, Babak
    Shahrbaf, Shirin
    Mirzakouchaki, Behnam
    Ghalichi, Farzan
    Ashtiani, Mohammed
    Martin, Nicolas
    [J]. DENTAL MATERIALS, 2014, 30 (04) : E89 - E97
  • [3] Implant surface design for improved implant stability - A study on Ti6Al4V dense and cellular structures produced by Selective Laser Melting
    Bartolomeu, F.
    Costa, M. M.
    Gomes, J. R.
    Alves, N.
    Abreu, C. S.
    Silva, F. S.
    Miranda, G.
    [J]. TRIBOLOGY INTERNATIONAL, 2019, 129 : 272 - 282
  • [4] Biocompatibility and antibacterial properties of zirconium nitride coating on titanium abutments: An in vitro study
    Brunello, Giulia
    Brun, Paola
    Gardin, Chiara
    Ferroni, Letizia
    Bressan, Eriberto
    Meneghello, Roberto
    Zavan, Barbara
    Sivolella, Stefano
    [J]. PLOS ONE, 2018, 13 (06):
  • [5] Mechanical analysis of a dental implant system under 3 contact conditions and with 2 mechanical factors
    Chang, Hung-Chih
    Li, Hung-Yuan
    Chen, Yen-Nien
    Chang, Chih-Han
    Wang, Chau-Hsiang
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2019, 122 (04) : 376 - 382
  • [6] Detection and identification of subcutaneous defects using ultrasonic waves in reflective test
    Dalir, M. Poursan
    Hedayati, E.
    Hedayati, A.
    [J]. JOURNAL OF MECHANICAL ENGINEERING AND SCIENCES, 2021, 15 (02) : 8003 - 8015
  • [7] Influence of cutting flutes on stress distribution for selected dental implants: Numerical studies
    Dhatrak, Pankaj
    Shirsat, Uddhav
    Sumanth, S.
    Deshmukh, Vijay
    [J]. MATERIALS TODAY-PROCEEDINGS, 2021, 38 : 2680 - 2686
  • [8] Numerical investigation on stress intensity around Bone-Implant interface by 3-Dimensional FEA and experimental verification by optical technique
    Dhatrak, Pankaj
    Shirsat, Uddhav
    Sumanth, S.
    Deshmukh, Vijay
    [J]. MATERIALS TODAY-PROCEEDINGS, 2021, 39 : 35 - 41
  • [9] Significance of Orthotropic Material Models to Predict Stress Around Bone-Implant Interface Using Numerical Simulation
    Dhatrak, Pankaj
    Girme, Vedant
    Shirsat, Uddhav
    Sumanth, S.
    Deshmukh, Vijay
    [J]. BIONANOSCIENCE, 2019, 9 (03) : 652 - 659
  • [10] Finite Element Analysis and Experimental Investigations on Stress Distribution of Dental Implants around Implant-Bone Interface
    Dhatrak, Pankaj
    Shirsat, Uddhav
    Sumanth, S.
    Deshmukh, Vijay
    [J]. MATERIALS TODAY-PROCEEDINGS, 2018, 5 (02) : 5641 - 5648