Improved Screening of Monoclonal Gammopathy Patients by MALDI-TOF Mass Spectrometry

被引:4
作者
Pecinka, Lukas [1 ,2 ]
Vlachova, Monika [3 ]
Moran, Lukas [4 ,5 ]
Gregorova, Jana [3 ]
Porokh, Volodymyr [2 ,4 ]
Kovacovicova, Petra [2 ,4 ]
Almasi, Martina [6 ]
Pour, Ludek [7 ]
Stork, Martin [7 ]
Havel, Josef [1 ,2 ]
Sevcikova, Sabina [3 ,6 ]
Vanhara, Petr [2 ,4 ]
机构
[1] Masaryk Univ, Fac Sci, Dept Chem, Brno 62500, Czech Republic
[2] St Annes Univ Hosp Brno, Int Clin Res Ctr, Brno 65691, Czech Republic
[3] Masaryk Univ, Fac Med, Dept Pathophysiol, Babak Myeloma Grp, Brno 62500, Czech Republic
[4] Masaryk Univ, Fac Med, Dept Histol & Embryol, Brno 62500, Czech Republic
[5] Masaryk Mem Canc Inst, Res Ctr Appl Mol Oncol RECAMO, Brno 60200, Czech Republic
[6] Univ Hosp Brno, Dept Clin Hematol, Brno 62500, Czech Republic
[7] Univ Hosp Brno, Dept Internal Med Hematol & Oncol, Brno 62500, Czech Republic
关键词
MALDI-TOF mass spectrometry; multiple myeloma; plasma cell leukemia; monoclonal gammopathy; principalcomponent analysis; machine learning; partial least-squares-discriminantanalysis; molecular profiling; fingerprinting; SAMPLE PREPARATION; IDENTIFICATION;
D O I
10.1021/jasms.3c00166
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Monoclonal gammopathies are a group of blood diseases characterized by presence of abnormal immunoglobulins in peripheral blood and/or urine of patients. Multiple myeloma and plasma cell leukemia are monoclonal gammopathies with unclear etiology, caused by malignant transformation of bone marrow plasma cells. Mass spectrometry with matrix-assisted laser desorption/ionization and time-of-flight detection is commonly used for investigation of the peptidome and small proteome of blood plasma with high accuracy, robustness, and cost-effectivity. In addition, mass spectrometry coupled with advanced statistics can be used for molecular profiling, classification, and diagnosis of liquid biopsies and tissue specimens in various malignancies. Despite the fact there have been fully optimized protocols for mass spectrometry of normal blood plasma available for decades, in monoclonal gammopathy patients, the massive alterations of biophysical and biochemical parameters of peripheral blood plasma often limit the mass spectrometry measurements. In this paper, we present a new two-step extraction protocol and demonstrated the enhanced resolution and intensity (>50x) of mass spectra obtained from extracts of peripheral blood plasma from monoclonal gammopathy patients. When coupled with advanced statistics and machine learning, the mass spectra profiles enabled the direct identification, classification, and discrimination of multiple myeloma and plasma cell leukemia patients with high accuracy and precision. A model based on PLS-DA achieved the best performance with 71.5% accuracy (95% confidence interval, CI = 57.1-83.3%) when the 10x repeated 5-fold CV was performed. In summary, the two-step extraction protocol improved the analysis of monoclonal gammopathy peripheral blood plasma samples by mass spectrometry and provided a tool for addressing the complex molecular etiology of monoclonal gammopathies.
引用
收藏
页码:2646 / 2653
页数:8
相关论文
共 50 条
  • [21] Reliability of MALDI-TOF mass spectrometry in the identification of anaerobic bacteria
    Vega-Castano, Silvia
    Ferreira, Laura
    Gonzalez-Avila, Magdalena
    Sanchez-Juanes, Fernando
    Inmaculada Garcia-Garcia, M.
    Elias Garcia-Sanchez, Jose
    Manuel Gonzalez-Buitrago, Jose
    Luis Munoz-Bellido, Juan
    ENFERMEDADES INFECCIOSAS Y MICROBIOLOGIA CLINICA, 2012, 30 (10): : 597 - 601
  • [22] Susceptibility Testing of Bacteria Using Maldi-Tof Mass Spectrometry
    Burckhardt, Irene
    Zimmermann, Stefan
    FRONTIERS IN MICROBIOLOGY, 2018, 9
  • [23] Characterisation of phosvitin phosphopeptides using MALDI-TOF mass spectrometry
    Samaraweera, Himali
    Moon, Sun Hee
    Lee, Eun Joo
    Grant, Jenifer
    Fouks, Jordan
    Choi, Inwook
    Suh, Joo Won
    Ahn, Dong U.
    FOOD CHEMISTRY, 2014, 165 : 98 - 103
  • [24] Differentiation and Relative Quantitation of Disaccharide Isomers by MALDI-TOF/TOF Mass Spectrometry
    Zhan, Lingpeng
    Xie, Xiaobo
    Li, Yafeng
    Liu, Huihui
    Xiong, Caiqiao
    Nie, Zongxiu
    ANALYTICAL CHEMISTRY, 2018, 90 (03) : 1525 - 1530
  • [25] Rapid differentiation of Enterococcus species by MALDI-TOF mass spectrometry
    Quintela Baluja, M.
    Boehme, K.
    Fernandez-No, I. C.
    Morandi, S.
    Franco, C.
    Gallardo, J. M.
    Barros-Velazquez, J.
    Calo-Mata, Pilar
    MICROBES IN APPLIED RESEARCH: CURRENT ADVANCES AND CHALLENGES, 2012, : 294 - 298
  • [26] MALDI-TOF Mass Spectrometry: Transformative Proteomics for Clinical Microbiology
    Patel, Robin
    CLINICAL CHEMISTRY, 2013, 59 (02) : 340 - 342
  • [27] Tyrosine residues modification studied by MALDI-TOF mass spectrometry
    Santrucek, J
    Strohalm, M
    Kadlcík, V
    Hynek, R
    Kodícek, M
    BIOCHEMICAL AND BIOPHYSICAL RESEARCH COMMUNICATIONS, 2004, 323 (04) : 1151 - 1156
  • [28] BARLEY VARIETIES DISCRIMINATION USING MALDI-TOF MASS SPECTROMETRY
    Hleba, Lukas
    Drab, Stefan
    Cisarova, Miroslava
    Cubon, Juraj
    JOURNAL OF MICROBIOLOGY BIOTECHNOLOGY AND FOOD SCIENCES, 2019, 8 (06): : 1347 - 1351
  • [29] MALDI-TOF mass spectrometry distinguishes daratumumab from M-proteins
    Moore, Lauren M.
    Cho, Sun
    Thoren, Katie L.
    CLINICA CHIMICA ACTA, 2019, 492 : 91 - 94
  • [30] Identification of the Trichophyton mentagrophytes complex species using MALDI-TOF mass spectrometry
    Packeu, Ann
    Hendrickx, Marijke
    Beguin, Hugues
    Martiny, Delphine
    Vandenberg, Olivier
    Detandt, Monique
    MEDICAL MYCOLOGY, 2013, 51 (06) : 580 - 585