Carotid Artery Stenting Using the Walrus Balloon Guide Catheter With Flow Reversal for Proximal Embolic Protection: Technical Description and Single-Center Case Series

被引:6
|
作者
Cappuzzo, Justin M. [1 ,2 ]
Monteiro, Andre [1 ,2 ]
Waqas, Muhammad [1 ,2 ]
Baig, Ammad A. [1 ,2 ]
Popoola, Daniel O. [3 ]
Almayman, Faisal [1 ,2 ]
Khawar, Wasiq I. [1 ]
Farkash, Zoe G. [2 ]
Davies, Jason M. [1 ,2 ,4 ,5 ,6 ]
Siddiqui, Adnan H. [1 ,2 ,5 ,6 ,7 ]
Levy, Elad I. [1 ,2 ,5 ,6 ,7 ]
Snyder, Kenneth V. [1 ,2 ,5 ,6 ,8 ]
机构
[1] SUNY Buffalo, Jacobs Sch Med & Biomed Sci, Dept Neurosurg, Buffalo, NY USA
[2] Gates Vasc Inst Kaleida Hlth, Dept Neurosurg, Buffalo, NY USA
[3] SUNY Buffalo, Jacobs Sch Med, Buffalo, NY USA
[4] SUNY Buffalo, Jacobs Sch Med & Biomed Sci, Dept Bioinformat, Buffalo, NY USA
[5] SUNY Buffalo, Canon Stroke & Vasc Res Ctr, Buffalo, NY USA
[6] Jacobs Inst, Buffalo, NY USA
[7] SUNY Buffalo, Jacobs Sch Med & Biomed Sci, Dept Radiol, Buffalo, NY USA
[8] SUNY Buffalo Neurosurg, 100 High St,Suite B4, Buffalo, NY 14203 USA
关键词
Carotid artery; Stenting; Carotid stenosis; Balloon guide catheter; Embolic protection; CEREBRAL PROTECTION; FILTER PROTECTION; REVASCULARIZATION; OCCLUSION; DEVICE; DISTAL; STROKE;
D O I
10.1227/ons.0000000000000442
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND:The use of modern transfemoral balloon guide catheters (BGC) for flow reversal during carotid artery stenting is scarcely described in the literature but represents a promising and efficient technique for embolic protection.OBJECTIVE:To describe a flow-reversal technique using the Walrus BGC (Q'Apel Medical Inc.) and report our center's experience.METHODS:We performed a retrospective analysis of data for consecutive patients aged 18 years or older who underwent elective carotid artery stenting with the use of flow reversal through the Walrus BGC between July 2020 and September 2021. Patient characteristics, procedural details, and clinical follow-up were evaluated.RESULTS:One hundred and five patients were included. Mean age was 69.8 +/- 9.4 years, and 36 (34.3%) were women. The most common comorbidities were hyperlipidemia (76.2%) and hypertension (57.1%). Fifty-nine (56.2%) patients were symptomatic. Ninety-nine (94.3%) patients had stenosis >= 70%. Contralateral stenosis >= 50% was present in 44 patients (41.9%). Distal filters were used after flow reversal was established in 90 patients (85.7%). Angioplasty was performed in 85 patients (80.9%). Stenting was successful in 100% of cases. No periprocedural transient ischemic attacks (TIAs) or strokes occurred. Stroke occurred in 2 patients (1.9%) during the 30-day follow-up period, resulting in 1 (0.9%) death.CONCLUSION:In our experience, this technique was safe, feasible, and efficient, with 100% technical success and no periprocedural thromboembolic complications. More extensive studies are needed to establish the role of proximal protection with flow reversal using modern BGCs.
引用
收藏
页码:11 / 16
页数:6
相关论文
共 9 条
  • [1] Transradial Carotid Artery Stenting Using Walrus Balloon Guide Catheter: Technical Aspects and Clinical Outcome
    Moldovan, Krisztina
    Yaeger, Kurt A.
    Al-Kawaz, Mais
    Scaggiante, Jacopo
    Kellner, Christopher P.
    De Leacy, Reade
    Fifi, Johanna T.
    Mocco, J.
    Majidi, Shahram
    OPERATIVE NEUROSURGERY, 2023, 25 (01) : 28 - 32
  • [2] Carotid Artery Stenting Without Embolic Protection Device: A Single-Center Experience
    Garriboli, Luca
    Pruner, Gianguido
    Miccoli, Tommaso
    Recchia, Andrea
    Tamellini, Paolo
    Jannello, Antonio Maria
    JOURNAL OF ENDOVASCULAR THERAPY, 2019, 26 (01) : 121 - 127
  • [3] Comparison of dual protection and distal filter protection as a distal embolic protection method during carotid artery stenting: a single-center carotid artery stenting experience
    Kajihara, Yosuke
    Sakamoto, Shigeyuki
    Kiura, Yoshihiro
    Mukada, Kazutoshi
    Chaki, Takahiro
    Kajihara, Shiro
    Kurisu, Kaoru
    NEUROSURGICAL REVIEW, 2015, 38 (04) : 671 - 676
  • [4] Acute and long-term results of carotid stenting under proximal embolic protection using the gore flow reversal system
    Bode, A.
    Franke, J.
    Rabe, K.
    Hornung, M.
    Wunderlich, N.
    Bertog, S. C.
    Sievert, H.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2013, 81 (01) : 133 - 141
  • [5] Comparison of dual protection and distal filter protection as a distal embolic protection method during carotid artery stenting: a single-center carotid artery stenting experience
    Yosuke Kajihara
    Shigeyuki Sakamoto
    Yoshihiro Kiura
    Kazutoshi Mukada
    Takahiro Chaki
    Shiro Kajihara
    Kaoru Kurisu
    Neurosurgical Review, 2015, 38 : 671 - 676
  • [6] Transfemoral Flow-Reversal for Carotid Artery Stenting with Balloon Guide Catheter: Proof of Concept with Robotic Transcranial Doppler
    Cappuzzo, Justin M.
    Monteiro, Andre
    Waqas, Muhammad
    Baig, Ammad A.
    Snyder, Kenneth, V
    Levy, Elad, I
    Siddiqui, Adnan H.
    INTERVENTIONAL NEURORADIOLOGY, 2024, 30 (03) : 422 - 423
  • [7] Carotid artery stenting with proximal embolic protection via the transbrachial approach: sheathless navigation of a 9-F balloon-guiding catheter
    Koge, Junpei
    Iwata, Tomonori
    Hashimoto, Tetsuya
    Mizuta, Shigehisa
    Nakamura, Yukihiko
    Tanaka, Eri
    Kawajiri, Masakazu
    Matsumoto, Shun-ichi
    Yamada, Takeshi
    NEURORADIOLOGY, 2018, 60 (10) : 1097 - 1101
  • [8] Carotid artery stenting with proximal embolic protection via the transbrachial approach: sheathless navigation of a 9-F balloon-guiding catheter
    Junpei Koge
    Tomonori Iwata
    Tetsuya Hashimoto
    Shigehisa Mizuta
    Yukihiko Nakamura
    Eri Tanaka
    Masakazu Kawajiri
    Shun-ichi Matsumoto
    Takeshi Yamada
    Neuroradiology, 2018, 60 : 1097 - 1101
  • [9] Stenting for Internal Carotid Artery Stenosis Associated with Persistent Primitive Hypoglossal Artery Using Proximal Flow Blockade and Distal Protection System: A Technical Case Report and Literature Review
    Murai, Satoshi
    Kusaka, Noboru
    Umakoshi, Michiari
    Itami, Hisakazu
    Otsuka, Shinji
    Nishiura, Tsukasa
    Ogihara, Kotaro
    JOURNAL OF STROKE & CEREBROVASCULAR DISEASES, 2016, 25 (06) : E98 - E102