Fully integrate d wearable micronee dle biosensing platform for wide-range and real-time continuous glucose monitoring

被引:10
|
作者
Li, Lei [1 ,2 ]
Zhou, Yujie [1 ,2 ]
Sun, Chenwei [1 ,2 ]
Zhou, Zhengming [3 ,4 ]
Zhang, Jieyu [1 ,2 ]
Xu, Yuanyuan [1 ,2 ]
Xiao, Xuanyu [1 ,2 ]
Deng, Hui [6 ]
Zhong, Yuting [1 ,2 ]
Li, Guoyuan [1 ,2 ]
Chen, Zhiyu [1 ,2 ]
Deng, Wei [5 ]
Hu, Xuefeng [6 ,7 ]
Wang, Yunbing [1 ,2 ,7 ]
机构
[1] Sichuan Univ, Natl Engn Res Ctr Biomat, Chengdu 610064, Sichuan, Peoples R China
[2] Sichuan Univ, Coll Biomed Engn, Chengdu 610065, Sichuan, Peoples R China
[3] Sichuan Univ, West China Sch Publ Hlth, Dept Nutr & Food Hyg, Chengdu 610041, Sichuan, Peoples R China
[4] Sichuan Univ, West China Hosp 4, Chengdu 610041, Sichuan, Peoples R China
[5] Chengdu Med Coll, Pidu Dist Peoples Hosp, Affiliated Hosp 3, Dept Orthoped, Chengdu 611730, Sichuan, Peoples R China
[6] Sichuan Univ, West China Sch Basic Med Sci & Forens Med, Chengdu 610041, Sichuan, Peoples R China
[7] 29 Wangjiang Rd, Chengdu, Peoples R China
关键词
Wearable biosensor; Continuous glucose monitoring; Microneedle; Interstitial fluid; Glutaraldehyde cross -linking; Prussian blue; PRUSSIAN BLUE; SENSOR; COMPOSITES; MANAGEMENT; STABILITY; ARRAYS;
D O I
10.1016/j.actbio.2023.12.044
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Wearable microneedle sensors for continuous glucose monitoring (CGM) have great potential for clinical impact by allowing access to large data sets to provide individualized treatment plans. To date, their development has been challenged by the accurate wide linear range tracking of interstitial fluid (ISF) glucose (Glu) levels. Here, we present a CGM platform consisting of a three -electrode microneedle electrochemical biosensor and a fully integrated radio -chemical analysis system. The long-term performance of the robust CGM on diabetic rats was achieved by electrodepositing Prussian blue (PB), and crosslinking glucose oxidase (GOx) and chitosan to form a 3D network using glutaraldehyde (GA). After redox by GOx, PB rapidly decomposes hydrogen peroxide and mediates charge transfer, while the 3D network and graphite powder provide enrichment and release sites for Glu and catalytic products, enabling a sensing range of 0.25-35 mM. Microneedle CGM has high sensitivity, good stability, and anti -interference ability. In diabetic rats, CGM can accurately monitor Glu levels in the ISF in real-time, which are highly consistent with levels measured by commercial Glu meters. These results indicate the feasibility and application prospects of the PB-based CGM for the clinical management of diabetes. Statement of Significance This study addresses the challenge of continuous glucose monitoring system design where the narrow linear range of sensing due to the miniaturization of sensors fails to meet the monitoring needs of clinical diabetic patients. This was achieved by utilizing a three-dimensional network of glutaraldehyde cross -linked glucose oxidase and chitosan. The unique topology of the 3D network provides a large number of sites for glucose enrichment and anchors the enzyme to the sensing medium and the conductive substrate through covalent bonding, successfully blocking the escape of the enzyme and the sensing medium and shortening the electron transfer and transmission path. (c) 2023 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:199 / 213
页数:15
相关论文
共 50 条
  • [31] Measures of Glycemic Variability in Type 1 Diabetes and the Effect of Real-Time Continuous Glucose Monitoring
    El-Laboudi, Ahmed H.
    Godsland, Ian F.
    Johnston, Desmond G.
    Oliver, Nick S.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2016, 18 (12) : 806 - 812
  • [32] Ward monitoring 4.0: real-time metabolic insights from continuous glucose monitoring into perioperative organ dysfunction
    Janssen, Henrike
    Jhanji, Shaman
    Oliver, Nick S.
    Ackland, Gareth L.
    BRITISH JOURNAL OF ANAESTHESIA, 2024, 132 (05) : 843 - 848
  • [33] Continuous glucose monitoring for automatic real-time assessment of eating events and nutrition: a scoping review
    Brummer, Julian
    Glasbrenner, Christina
    Figueroa, Sieglinde Hechenbichler
    Koehler, Karsten
    Hoechsmann, Christoph
    FRONTIERS IN NUTRITION, 2024, 10
  • [34] Accuracy and impact on quality of life of real-time continuous glucose monitoring in children with hyperinsulinaemic hypoglycaemia
    Sivasubramanian, Madhini
    Avari, Parizad
    Gilbert, Clare
    Doodson, Louise
    Morgan, Kate
    Oliver, Nick
    Shah, Pratik
    FRONTIERS IN ENDOCRINOLOGY, 2023, 14
  • [35] Effects of real-time continuous glucose monitoring in type 1 diabetes: a meta-analysis of randomized controlled trials
    Dicembrini, I.
    Cosentino, C.
    Monami, M.
    Mannucci, E.
    Pala, L.
    ACTA DIABETOLOGICA, 2021, 58 (04) : 401 - 410
  • [36] Real-time continuous glucose monitoring improves glycemic control and reduces hypoglycemia: Real-world data
    Kant, Ravi
    Antony, Mc Anto
    Geurkink, David
    Gilreath, Nathan
    Chandra, Lakshya
    Zipprer, Elizabeth
    Munir, Kashif M.
    Chandra, Rashmi
    Parker, Veronica G.
    Verma, Vipin
    PRIMARY CARE DIABETES, 2022, 16 (06) : 786 - 790
  • [37] Real-time continuous glucose monitoring using Guardian®RT:: from research to clinical practice
    Tubiana-Rufi, N.
    Riveline, J. -P.
    Dardari, D.
    DIABETES & METABOLISM, 2007, 33 (06) : 415 - 420
  • [38] Lower Glycated Hemoglobin with Real-Time Continuous Glucose Monitoring Than with Intermittently Scanned Continuous Glucose Monitoring After 1 Year: The CORRIDA LIFE Study
    Radovnicka, Lucie
    Haskova, Aneta
    Do, Quoc Dat
    Horova, Eva
    Navratilova, Vendula
    Mikes, Ondrej
    Cihlar, David
    Parkin, Christopher G.
    Grunberger, George
    Prazny, Martin
    Soupal, Jan
    DIABETES TECHNOLOGY & THERAPEUTICS, 2022, 24 (12) : 859 - 867
  • [39] Switching from Intermittently Scanned Continuous Glucose Monitoring to Real-Time Continuous Glucose Monitoring with a Predictive Urgent Low Soon Alert Reduces Exposure to Hypoglycemia
    Preechasuk, Lukana
    Avari, Parizad
    Oliver, Nick
    Reddy, Monika
    DIABETES TECHNOLOGY & THERAPEUTICS, 2024, 26 (07) : 498 - 502
  • [40] Accuracy to detect neonatal hyperglycaemia using real-time continuous glucose monitoring during postoperative period
    Wasiq, Mohammed Abdul
    Behura, Sushree Smita
    Sahoo, Swaranjika
    Panda, Santosh Kumar
    EUROPEAN JOURNAL OF PEDIATRICS, 2023, 182 (03) : 1083 - 1087