Fully integrate d wearable micronee dle biosensing platform for wide-range and real-time continuous glucose monitoring

被引:10
|
作者
Li, Lei [1 ,2 ]
Zhou, Yujie [1 ,2 ]
Sun, Chenwei [1 ,2 ]
Zhou, Zhengming [3 ,4 ]
Zhang, Jieyu [1 ,2 ]
Xu, Yuanyuan [1 ,2 ]
Xiao, Xuanyu [1 ,2 ]
Deng, Hui [6 ]
Zhong, Yuting [1 ,2 ]
Li, Guoyuan [1 ,2 ]
Chen, Zhiyu [1 ,2 ]
Deng, Wei [5 ]
Hu, Xuefeng [6 ,7 ]
Wang, Yunbing [1 ,2 ,7 ]
机构
[1] Sichuan Univ, Natl Engn Res Ctr Biomat, Chengdu 610064, Sichuan, Peoples R China
[2] Sichuan Univ, Coll Biomed Engn, Chengdu 610065, Sichuan, Peoples R China
[3] Sichuan Univ, West China Sch Publ Hlth, Dept Nutr & Food Hyg, Chengdu 610041, Sichuan, Peoples R China
[4] Sichuan Univ, West China Hosp 4, Chengdu 610041, Sichuan, Peoples R China
[5] Chengdu Med Coll, Pidu Dist Peoples Hosp, Affiliated Hosp 3, Dept Orthoped, Chengdu 611730, Sichuan, Peoples R China
[6] Sichuan Univ, West China Sch Basic Med Sci & Forens Med, Chengdu 610041, Sichuan, Peoples R China
[7] 29 Wangjiang Rd, Chengdu, Peoples R China
关键词
Wearable biosensor; Continuous glucose monitoring; Microneedle; Interstitial fluid; Glutaraldehyde cross -linking; Prussian blue; PRUSSIAN BLUE; SENSOR; COMPOSITES; MANAGEMENT; STABILITY; ARRAYS;
D O I
10.1016/j.actbio.2023.12.044
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Wearable microneedle sensors for continuous glucose monitoring (CGM) have great potential for clinical impact by allowing access to large data sets to provide individualized treatment plans. To date, their development has been challenged by the accurate wide linear range tracking of interstitial fluid (ISF) glucose (Glu) levels. Here, we present a CGM platform consisting of a three -electrode microneedle electrochemical biosensor and a fully integrated radio -chemical analysis system. The long-term performance of the robust CGM on diabetic rats was achieved by electrodepositing Prussian blue (PB), and crosslinking glucose oxidase (GOx) and chitosan to form a 3D network using glutaraldehyde (GA). After redox by GOx, PB rapidly decomposes hydrogen peroxide and mediates charge transfer, while the 3D network and graphite powder provide enrichment and release sites for Glu and catalytic products, enabling a sensing range of 0.25-35 mM. Microneedle CGM has high sensitivity, good stability, and anti -interference ability. In diabetic rats, CGM can accurately monitor Glu levels in the ISF in real-time, which are highly consistent with levels measured by commercial Glu meters. These results indicate the feasibility and application prospects of the PB-based CGM for the clinical management of diabetes. Statement of Significance This study addresses the challenge of continuous glucose monitoring system design where the narrow linear range of sensing due to the miniaturization of sensors fails to meet the monitoring needs of clinical diabetic patients. This was achieved by utilizing a three-dimensional network of glutaraldehyde cross -linked glucose oxidase and chitosan. The unique topology of the 3D network provides a large number of sites for glucose enrichment and anchors the enzyme to the sensing medium and the conductive substrate through covalent bonding, successfully blocking the escape of the enzyme and the sensing medium and shortening the electron transfer and transmission path. (c) 2023 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:199 / 213
页数:15
相关论文
共 50 条
  • [21] The value of real-time continuous glucose monitoring in premature infants of diabetic mothers
    Saw, Hean-Pat
    Yao, Nai-Wei
    Chiu, Cheng-Di
    Chen, Jia-Yuh
    PLOS ONE, 2017, 12 (10):
  • [22] Real-time continuous glucose monitoring system for treatment of diabetes: a systematic review
    Hoeks, L. B. E. A.
    Greven, W. L.
    de Valk, H. W.
    DIABETIC MEDICINE, 2011, 28 (04) : 386 - 394
  • [23] Human sweat-based wearable glucose sensor on cotton fabric for real-time monitoring
    Anoop Singh
    Asha Sharma
    Sandeep Arya
    Journal of Analytical Science and Technology, 13
  • [24] Evaluating the precision and reliability of real-time continuous glucose monitoring systems in ambulatory settings: a systematic review
    Davila-Ruales, Valentina
    Gilon, Laura F.
    Gomez, Ana M.
    Munoz, Oscar M.
    Serrano, Maria N.
    Henao, Diana C.
    THERAPEUTIC ADVANCES IN ENDOCRINOLOGY AND METABOLISM, 2024, 15
  • [25] Real-time intradermal continuous glucose monitoring using a minimally invasive microneedle-based system
    Ribet, Federico
    Stemme, Goran
    Roxhed, Niclas
    BIOMEDICAL MICRODEVICES, 2018, 20 (04)
  • [26] Evaluation of a Novel Real-Time Continuous Glucose-Monitoring System for Use in Cats
    Moretti, S.
    Tschuor, F.
    Osto, M.
    Franchini, M.
    Wichert, B.
    Ackermann, M.
    Lutz, T. A.
    Reusch, C. E.
    Zini, E.
    JOURNAL OF VETERINARY INTERNAL MEDICINE, 2010, 24 (01): : 120 - 126
  • [27] Sustainable Use of a Real-Time Continuous Glucose Monitoring System from 2018 to 2020
    van der Linden, Joost
    Welsh, John B.
    Walker, Tomas C.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2021, 23 (07) : 508 - 511
  • [28] Mitigation of Rebound Hyperglycemia With Real-Time Continuous Glucose Monitoring Data and Predictive Alerts
    Acciaroli, Giada
    Welsh, John B.
    Akturk, Halis Kaan
    JOURNAL OF DIABETES SCIENCE AND TECHNOLOGY, 2022, 16 (03): : 677 - 682
  • [29] Revolutionizing OGTT: Unlocking the Real-Time Insights and Expanded Data of Continuous Glucose Monitoring
    Seetharaman, Sujatha
    Ekhlaspour, Laya
    JOURNAL OF CLINICAL ENDOCRINOLOGY & METABOLISM, 2025,
  • [30] 3D Porous Stacked Organic Electrochemical Transistor for Wearable Glucose Sensing: Enhancing Comfort, Breathability, and Real-Time Monitoring
    Liu, Changjian
    Huang, Wei
    Guo, Haihong
    Peng, Yujie
    Yu, Junsheng
    2024 IEEE 3RD INTERNATIONAL CONFERENCE ON MICRO/NANO SENSORS FOR AI, HEALTHCARE, AND ROBOTICS, NSENS, 2024, : 81 - 85