Fully integrate d wearable micronee dle biosensing platform for wide-range and real-time continuous glucose monitoring

被引:10
|
作者
Li, Lei [1 ,2 ]
Zhou, Yujie [1 ,2 ]
Sun, Chenwei [1 ,2 ]
Zhou, Zhengming [3 ,4 ]
Zhang, Jieyu [1 ,2 ]
Xu, Yuanyuan [1 ,2 ]
Xiao, Xuanyu [1 ,2 ]
Deng, Hui [6 ]
Zhong, Yuting [1 ,2 ]
Li, Guoyuan [1 ,2 ]
Chen, Zhiyu [1 ,2 ]
Deng, Wei [5 ]
Hu, Xuefeng [6 ,7 ]
Wang, Yunbing [1 ,2 ,7 ]
机构
[1] Sichuan Univ, Natl Engn Res Ctr Biomat, Chengdu 610064, Sichuan, Peoples R China
[2] Sichuan Univ, Coll Biomed Engn, Chengdu 610065, Sichuan, Peoples R China
[3] Sichuan Univ, West China Sch Publ Hlth, Dept Nutr & Food Hyg, Chengdu 610041, Sichuan, Peoples R China
[4] Sichuan Univ, West China Hosp 4, Chengdu 610041, Sichuan, Peoples R China
[5] Chengdu Med Coll, Pidu Dist Peoples Hosp, Affiliated Hosp 3, Dept Orthoped, Chengdu 611730, Sichuan, Peoples R China
[6] Sichuan Univ, West China Sch Basic Med Sci & Forens Med, Chengdu 610041, Sichuan, Peoples R China
[7] 29 Wangjiang Rd, Chengdu, Peoples R China
关键词
Wearable biosensor; Continuous glucose monitoring; Microneedle; Interstitial fluid; Glutaraldehyde cross -linking; Prussian blue; PRUSSIAN BLUE; SENSOR; COMPOSITES; MANAGEMENT; STABILITY; ARRAYS;
D O I
10.1016/j.actbio.2023.12.044
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Wearable microneedle sensors for continuous glucose monitoring (CGM) have great potential for clinical impact by allowing access to large data sets to provide individualized treatment plans. To date, their development has been challenged by the accurate wide linear range tracking of interstitial fluid (ISF) glucose (Glu) levels. Here, we present a CGM platform consisting of a three -electrode microneedle electrochemical biosensor and a fully integrated radio -chemical analysis system. The long-term performance of the robust CGM on diabetic rats was achieved by electrodepositing Prussian blue (PB), and crosslinking glucose oxidase (GOx) and chitosan to form a 3D network using glutaraldehyde (GA). After redox by GOx, PB rapidly decomposes hydrogen peroxide and mediates charge transfer, while the 3D network and graphite powder provide enrichment and release sites for Glu and catalytic products, enabling a sensing range of 0.25-35 mM. Microneedle CGM has high sensitivity, good stability, and anti -interference ability. In diabetic rats, CGM can accurately monitor Glu levels in the ISF in real-time, which are highly consistent with levels measured by commercial Glu meters. These results indicate the feasibility and application prospects of the PB-based CGM for the clinical management of diabetes. Statement of Significance This study addresses the challenge of continuous glucose monitoring system design where the narrow linear range of sensing due to the miniaturization of sensors fails to meet the monitoring needs of clinical diabetic patients. This was achieved by utilizing a three-dimensional network of glutaraldehyde cross -linked glucose oxidase and chitosan. The unique topology of the 3D network provides a large number of sites for glucose enrichment and anchors the enzyme to the sensing medium and the conductive substrate through covalent bonding, successfully blocking the escape of the enzyme and the sensing medium and shortening the electron transfer and transmission path. (c) 2023 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:199 / 213
页数:15
相关论文
共 50 条
  • [1] Interstitial fluid glucose time-lag correction for real-time continuous glucose monitoring
    Keenan, D. Barry
    Mastrototaro, John J.
    Weinzimer, Stuart A.
    Steil, Garry M.
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2013, 8 (01) : 81 - 89
  • [2] Wearable Platform for Real-time Monitoring of Sodium in Sweat
    McCaul, Margaret
    Porter, Adam
    Barrett, Ruairi
    White, Paddy
    Stroiescu, Florien
    Wallace, Gordon
    Diamond, Dermot
    CHEMPHYSCHEM, 2018, 19 (12) : 1531 - 1536
  • [3] An integrated wearable self-powered platform for real-time and continuous temperature monitoring
    Li, Weiyan
    Song, Zhongqian
    Kong, Huijun
    Chen, Minqi
    Liu, Shengjie
    Bao, Yu
    Ma, Yingming
    Sun, Zhonghui
    Liu, Zhenbang
    Wang, Wei
    Niu, Li
    NANO ENERGY, 2022, 104
  • [4] A long lifetime and highly sensitive wearable microneedle sensor for the continuous real-time monitoring of glucose in interstitial fluid
    Yin, Sijie
    Yu, Zhiqiang
    Song, Ningning
    Guo, Zhanjun
    Li, Wei
    Ma, Jinhang
    Wang, Xiaoyan
    Liu, Junyao
    Liang, Minmin
    BIOSENSORS & BIOELECTRONICS, 2024, 244
  • [5] Real-Time Continuous Glucose Monitoring in the Hospital: A Real-World Experience
    Bagsic, Samantha R. Spierling R.
    Fortmann, Addie L. L.
    Belasco, Rebekah
    Bastian, Alessandra
    Lohnes, Suzanne
    Ritko, Anna
    Sandoval, Haley
    Chichmarenko, Mariya
    Soriano, Emily C. C.
    Talavera, Laura
    Philis-Tsimikas, Athena
    JOURNAL OF DIABETES SCIENCE AND TECHNOLOGY, 2023, 17 (03): : 656 - 666
  • [6] Real-Time Improvement of Continuous Glucose Monitoring Accuracy
    Facchinetti, Andrea
    Sparacino, Giovanni
    Guerra, Stefania
    Luijf, Yoeri M.
    DeVries, J. Hans
    Mader, Julia K.
    Ellmerer, Martin
    Benesch, Carsten
    Heinemann, Lutz
    Bruttomesso, Daniela
    Avogaro, Angelo
    Cobelli, Claudio
    DIABETES CARE, 2013, 36 (04) : 793 - 800
  • [7] Practical Aspects of Real-Time Continuous Glucose Monitoring
    Gilliam, Lisa K.
    Hirsch, Irl B.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2009, 11 : S75 - S82
  • [8] Benefits of Real-Time Continuous Glucose Monitoring in Pregnancy
    Yamamoto, Jennifer M.
    Murphy, Helen R.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2021, 23 : S8 - S14
  • [9] Real-Time Continuous Glucose Monitoring During the Coronavirus Disease 2019 Pandemic and Its Impact on Time in Range
    van der Linden, Joost
    Welsh, John B.
    Hirsch, Irl B.
    Garg, Satish K.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2021, 23 : S1 - S7
  • [10] Assessment of glucose kinetics with real-time continuous glucose monitoring during labor
    Maki, Jota
    Eto, Eriko
    Tamada, Shoko
    Mitsui, Takashi
    Hayata, Kei
    Nakamura, Keiichiro
    Hiramatsu, Yuji
    Masuyama, Hisashi
    JOURNAL OF OBSTETRICS AND GYNAECOLOGY RESEARCH, 2019, 45 (09) : 1851 - 1859