Hardware, methodology and applications of 2+D backscatter Mossbauer spectroscopy with simultaneous x-ray and γ-ray detection

被引:1
作者
O'Brien, Jack [1 ,2 ]
Baghbaderani, Hasan Ahmadian [1 ,2 ,3 ]
Keller, Frederico O. [4 ]
Dempsey, Nora [4 ]
Lewis, Laura H. [5 ]
Stamenov, Plamen [1 ,2 ,3 ]
机构
[1] Trinity Coll Dublin, Sch Phys, Dublin, Ireland
[2] Trinity Coll Dublin, CRANN, Dublin, Ireland
[3] Univ Coll Cork, Tyndall Natl Inst, Microsyst Ctr, Cork, Ireland
[4] Univ Grenoble Alpes, Inst NEEL, CNRS, F-38000 Grenoble, France
[5] Northeastern Univ, Dept Chem Engn, Dept Mech & Ind Engn, Boston, MA 02115 USA
基金
爱尔兰科学基金会; 美国国家科学基金会;
关键词
backscatter Mossbauer spectroscopy; conversion x-ray Mossbauer spectroscopy; multi-parameter analysis; energy-resolved detection; iron fluorescence; full-Hamiltonian fitting; atomic crystalline order; MAGNETIC-PROPERTIES; TETRATAENITE; METEORITES; FENI;
D O I
10.1088/1361-6501/ad044b
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
A unique method is presented for the acquisition and analysis of Fe-57 backscatter Mossbauer spectra with simultaneous detection of the resonant 14.4 keV gamma-rays and the characteristic 6.4 keV x-rays, using a custom-built multi-parameter analyser constructed on the basis of commercial analogue to digital converters and high-speed digital latches. The system allows for the simultaneous registration of Doppler-modulation velocities and photon energies, with up to 4096 and 8192 digital channels respectively. This arrangement is in contrast to most related systems, which detect at a single narrow energy window per detector. Samples of arbitrary atomic structure, morphology and surface topography can be studied without altering the setup or the analysis procedure, provided that the samples are at least micrometre sized. The hardware and software that are used to acquire data with minimal dead time are described and the custom and self-contained methods for post-measurement energy discrimination, background correction and velocity-axis folding are discussed. The data are fit using a general Hamiltonian model for the nuclear energy levels of Fe-57 and a quantum mechanical description of the angular momentum coupling is utilised, with consideration of the crystalline and chemical disorder of the sample under examination. Three examples of distinct magnetic systems, with thicknesses ranging from 5 mu m to 6 mm, that were studied using this method are presented, these are: an amorphous CoFeB-based ribbon with ultra-soft coercivity for high-frequency applications, magnetically hard Nd-Fe-B thick films on Si substrates, examined in both as-deposited and annealed states, and a sample from the nickel-rich iron meteorite NWA 6259 that contains the atomically ordered, elevated coercivity, L1(0) phase of FeNi, tetrataenite. The wide applicability and usefulness of this method is thus demonstrated on three distinct sample morphologies that required little to no surface preparation prior to examination.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] Thickness-Dependent Electronic Structure of Intermetallic CeCo2 Nanothin Films Studied by X-ray Absorption Spectroscopy
    Dong, Chung-Li
    Chen, Chi-Liang
    Asokan, Kandasami
    Chang, Ching-Lin
    Chen, Yang-Yuan
    Lee, Jyh-Fu
    Guo, Jinghua
    LANGMUIR, 2009, 25 (13) : 7568 - 7572
  • [32] X-ray diffraction and Mossbauer studies on superparamagnetic nickel ferrite (NiFe2O4) obtained by the proteic sol-gel method
    Nogueira, N. A. S.
    Utuni, V. H. S.
    Silva, Y. C.
    Kiyohara, P. K.
    Vasconcelos, I. F.
    Miranda, M. A. R.
    Sasaki, J. M.
    MATERIALS CHEMISTRY AND PHYSICS, 2015, 163 : 402 - 406
  • [33] An investigation of the Fe and Mo oxidation states in Sr2Fe2-xMoxO6 (0.25 ≤ x ≤ 1.0) double perovskites by X-ray absorption spectroscopy
    Hayes, John R.
    Grosvenor, Andrew P.
    JOURNAL OF ALLOYS AND COMPOUNDS, 2012, 537 : 323 - 331
  • [34] Local structure of Fe-doped In2O3 films investigated by X-ray absorption fine structure spectroscopy
    An, Yukai
    Wang, Shiqi
    Feng, Deqiang
    Wu, Zhonghua
    Liu, Jiwen
    APPLIED PHYSICS A-MATERIALS SCIENCE & PROCESSING, 2014, 115 (03): : 823 - 828
  • [35] Electronic structure of the Fe2+ compound FeWO4: A combined experimental and theoretical x-ray photoelectron spectroscopy study
    Altendorf, S. G.
    Takegami, D.
    Melendez-Sans, A.
    Chang, C. F.
    Yoshimura, M.
    Tsuei, K. D.
    Tanaka, A.
    Schmidt, M.
    Tjeng, L. H.
    PHYSICAL REVIEW B, 2023, 108 (08)
  • [36] Assessment of the optimum degree of Sr3Fe2MoO9 electron-doping through oxygen removal: An X-ray powder diffraction and 57Fe Mossbauer spectroscopy study
    Lopez, Carlos A.
    Viola, Maria del C.
    Pedregosa, Jose C.
    Mercader, Roberto C.
    MATERIALS RESEARCH BULLETIN, 2010, 45 (10) : 1520 - 1526
  • [37] X-ray diffraction and Raman spectroscopy studies of temperature and composition induced phase transitions in Ba2-xSrxZnWO6 (0 ≤ x ≤ 2) double perovskite oxides
    Manoun, Bouchaib
    Ezzahi, A.
    Benmokhtar, S.
    Ider, A.
    Lazor, P.
    Bih, L.
    Igartua, J. M.
    JOURNAL OF ALLOYS AND COMPOUNDS, 2012, 533 : 43 - 52
  • [38] Mossbauer and X-ray diffraction study of Co2+-Si4+ substituted M-type barium hexaferrite BaFe12-2xCoxSixO19 ± γ
    Solovyova, E. D.
    Pashkova, E. V.
    Ivanitski, V. P.
    V'yunov, O. I.
    Belous, A. G.
    JOURNAL OF MAGNETISM AND MAGNETIC MATERIALS, 2013, 330 : 72 - 75
  • [39] Analysis of ordinary chondrites using powder X-ray diffraction: 2. Applications to ordinary chondrite parent-body processes
    Dunn, Tasha L.
    McSween, Harry Y., Jr.
    McCoy, Timothy J.
    Cressey, Gordon
    METEORITICS & PLANETARY SCIENCE, 2010, 45 (01) : 135 - 156
  • [40] Synthesis under usual conditions, X-ray photoelectron spectroscopy and magnetic properties of Re1-xMnxO2 oxides with rutile structure
    Bazuev, G. V.
    Chupakhina, T. I.
    Korolyov, A. V.
    Kuznetsov, M. V.
    MATERIALS CHEMISTRY AND PHYSICS, 2010, 124 (2-3) : 946 - 951