Experimental Studies on the Seismic Performance of Underwater Concrete Piers Strengthened by Self-Stressed Anti-Washout Concrete and Segments

被引:1
作者
Sun, Yu [1 ,2 ]
Xu, Wansong [1 ,3 ]
Shen, Sheng [1 ]
机构
[1] Fuzhou Univ, Coll Civil Engn, Fuzhou 350108, Peoples R China
[2] Shanghai Construct Decorat Engn Grp Co Ltd, Shanghai 200040, Peoples R China
[3] China Power Engn Consulting Grp, East China Elect Power Design Inst Co Ltd, Shanghai 200333, Peoples R China
来源
APPLIED SCIENCES-BASEL | 2023年 / 13卷 / 21期
关键词
underwater concrete pier; seismic performance; self-stressed anti-washout concrete; segment assembly; undrained strengthening; quasi-static test; MECHANICAL-BEHAVIOR; BRIDGE PIERS; STEEL TUBE; COLUMNS; FRP; COMPOSITES;
D O I
10.3390/app132112034
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Given that the existing drainage strengthening methods for underwater damaged piers are expensive, inefficient, and cause shipping traffic disruptions, an urgent need exists to explore undrained strengthening methods, such as the precast concrete segment assembly method (PCSAM). However, the PCSAM has certain limitations, including a considerable strength loss of filled concrete, poor accuracy, poor connection performance of the segment sleeves, etc. Hence, this study developed an improved PCSAM (IPCSAM) by adopting self-stressed anti-washout concrete (SSAWC) as the filling material and developing a lining concrete segment sleeve (LCSS) based on the design principle of shield tunnel lining segments. Subsequently, the seismic performance of the strengthened piers was investigated. First, nine 1/5-scale pier column specimens were designed by considering different influencing factors: the self-stress of the SSAWC, LCSS reinforcement ratio, and initial damage and length-diameter ratio of the pier column. These specimens were tested under low reversed cyclic loading. Second, an extended parameter analysis was performed based on the established numerical models consistent with the quasi-static test's parameter settings. Finally, a restoring force model of the strengthened piers, including the trilinear skeleton curve model and hysteresis curve model, was established based on the results of the quasi-static test and parameter analysis. The results indicated that the bearing capacity, ductility, and initial stiffness of the specimens strengthened using the IPCSAM increased by approximately 83.5-106.4%, 16.3-50.2%, and 83.9-177.3%, respectively, with the energy dissipation capacity also significantly improved. The self-stress of the SSAWC should not exceed 2.2 MPa, and the recommended ratio of the LCSS thickness to pier column diameter is 1/10. Additionally, the proposed restoring force model is highly accurate and applicable, able to provide a reference for the practical seismic strengthening design of piers.
引用
收藏
页数:40
相关论文
共 77 条
  • [1] ACI committee 318, 2014, BUILDING CODE REQUIR
  • [2] [Anonymous], 2013, 503672013 GB
  • [3] [Anonymous], 2010, Code for design of concrete structures
  • [4] [Anonymous], 2015, IBC-2015
  • [5] [Anonymous], 2010, AISC/ASCI 341-10
  • [6] [Anonymous], 2016, AISC/ASCI 360-16
  • [7] [Anonymous], 2014, GB 50936-2014
  • [8] [Anonymous], 2021, DL/T 5117-2021
  • [9] [Anonymous], 2010, ASCESEI710
  • [10] CEN (European Committee for Standardization), 2004, EUR 4 DES COMP STEEL