Usefulness of UF-5000 automatic screening system in UTI diagnosis

被引:4
作者
Toledo, Hector [1 ]
Punzon, Sara G. [1 ]
Martin-Gutierrez, Guillermo [1 ]
Perez, Juan A. [1 ]
Lepe, Jose A. [1 ]
机构
[1] Hosp Univ Virgen Rocio Sevilla, Serv Microbiol, Seville, Spain
关键词
UTI; Urinalysis; Cytometer; Bacterial count; SYSMEX UF-1000I; FLOW CYTOMETER;
D O I
10.1007/s42770-023-01052-9
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
We have evaluated the Sysmex UF-5000 cytometer use in microbiology for the screening of negative urines, looking for cut-off points to detect bacteria and leukocytes. The number of processed urines was 3569, the highest to date in these studies. The best general cut-off point has been 100 bact/& mu;l, giving an area under the ROC curve of 0.868, a sensitivity of 96%, a specificity of 50%, 1.17% of false negatives, and saving 40% of cultures. The PPV and NPV have been 35.5 and 95.4 respectively. The leukocyte count has not been useful. Finally, we have evaluated urine screening usefulness, concluding that in laboratories such as ours (284 urines/working day) or smaller, it is not cost-effective.
引用
收藏
页码:1803 / 1808
页数:6
相关论文
共 24 条
[1]   Evaluation of the sysmex UF-5000 fluorescence flow cytometer as a screening platform for ruling out urinary tract infections in elderly patients presenting at the Emergency Department [J].
Alenkaer, Lasse Krogh ;
Pedersen, Lise ;
Szecsi, Pal Bela ;
Bjerrum, Poul Jannik .
SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 2021, 81 (05) :379-384
[2]   Microbiological diagnosis of urinary tract infections [J].
Andreu, Antonia ;
Cacho, Juana ;
Coira, Amparo ;
Antonio Lepe, Jose .
ENFERMEDADES INFECCIOSAS Y MICROBIOLOGIA CLINICA, 2011, 29 (01) :52-57
[3]   European guidelines for urinalysis: a collaborative document produced by European clinical microbiologists and clinical chemists under ECLM in collaboration with ESCMID [J].
Aspevall, O ;
Hallander, H ;
Gant, V ;
Kouri, T .
CLINICAL MICROBIOLOGY AND INFECTION, 2001, 7 (04) :173-178
[4]   Screening for Urinary Tract Infection with the Sysmex UF-1000i Urine Flow Cytometer [J].
Broeren, Maarten A. C. ;
Bahceci, Semiha ;
Vader, Huib L. ;
Arents, Niek L. A. .
JOURNAL OF CLINICAL MICROBIOLOGY, 2011, 49 (03) :1025-1029
[5]   Evaluation of the Sysmex UF-1000i flow cytometer for screening of urinary tract infection [J].
de Frutos-Serna, Monica ;
Luz Asensio-Calle, Maria ;
Maria Haro-Perez, Ana ;
Maria Blazquez-de Castro, Ana ;
Nieves Gutierrez-Zufiaurre, Maria ;
Iglesias-Garcia, Jesus .
ENFERMEDADES INFECCIOSAS Y MICROBIOLOGIA CLINICA, 2014, 32 (03) :147-151
[6]   Evaluation of the new Sysmex OF-5000 fluorescence flow cytometry analyser for ruling out bacterial urinary tract infection and for prediction of Gram negative bacteria in urine cultures [J].
De Rosa, Rita ;
Grosso, Shamanta ;
Lorenzi, Giada ;
Bruschetta, Graziano ;
Camporese, Alessandro .
CLINICA CHIMICA ACTA, 2018, 484 :171-178
[7]   Evaluation of the Sysmex UF1000i flow cytometer for ruling out bacterial urinary tract infection [J].
De Rosa, Rita ;
Grosso, Shamanta ;
Bruschetta, Graziano ;
Avolio, Manuela ;
Stano, Paola ;
Modolo, Maria Luisa ;
Camporese, Alessandro .
CLINICA CHIMICA ACTA, 2010, 411 (15-16) :1137-1142
[8]   Comparison of the reliability of Gram-negative and Gram-positive flags of the Sysmex UF-5000 with manual Gram stain and urine culture results [J].
Enko, Dietmar ;
Stelzer, Ingeborg ;
Boeckl, Michael ;
Schnedl, Wolfgang J. ;
Meinitzer, Andreas ;
Herrmann, Markus ;
Toetsch, Martin ;
Gehrer, Michael .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2021, 59 (03) :619-624
[9]  
Gässler N, 2006, CLIN NEPHROL, V66, P331
[10]  
Grabe M., 2015, Eur. Assoc. Urol