Efficiency and safety of high-power ablation guided by Lesion size index: An ex vivo porcine heart study

被引:1
|
作者
Huo, Shengqi [1 ]
Wang, Qian [1 ]
Jiang, Yue [1 ]
Shi, Wei [1 ]
Luo, Pengcheng [2 ]
Guo, Junyi [1 ]
Peng, Dewei [1 ]
Zhu, Mengying [1 ]
Men, Lintong [1 ]
Jiang, Tao [2 ]
Wang, Moran [1 ]
Peng, Lulu [1 ]
Huang, Bingyu [1 ]
Shi, Meijing [4 ]
Zhu, Bo [5 ]
Bai, Rong [6 ]
Day, John D. D. [3 ]
Lv, Jiagao [1 ]
Lin, Li [1 ]
机构
[1] Huazhong Univ Sci & Technol, Tongji Hosp, Tongji Med Coll, Div Cardiol,Dept Internal Med, Jiefang Ave 1095,POB 430030, Wuhan, Peoples R China
[2] Huazhong Univ Sci & Technol, Tongji Hosp, Tongji Med Coll, Dept Geriatr, Wuhan, Peoples R China
[3] Intermt Med Ctr, Intermt Med Ctr Heart Inst, Salt Lake City, UT USA
[4] Gen Hosp Yangtze River Shipping, Dept Emergence, Wuhan, Peoples R China
[5] Jianghan Univ, Dept Internal Med, Div Cardiol, Hubei 3 Peoples Hosp, Wuhan, Peoples R China
[6] Capital Med Univ, Beijing Anzhen Hosp, Dept Cardiol, Beijing, Peoples R China
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 2023年 / 46卷 / 06期
关键词
atrial fibrillation; high power; lesion size index; radiofrequency catheter ablation; SHORT-DURATION ABLATION; ATRIAL-FIBRILLATION; CONTACT FORCE; CATHETER ABLATION; PREDICTORS;
D O I
10.1111/pace.14659
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BackgroundAlthough Lesion size index (LSI) has been reported to highly predict radiofrequency lesion size in vitro, its accuracy in lesion size and steam pop estimation has not been well investigated for every possible scenario. MethodsInitially, radiofrequency ablations were performed on porcine myocardial slabs at various power, CF, and time settings with blinded LSI. Subsequently, radiofrequency power at 20, 30, 40, 50, and 60 W was applied at CF values of 5, 10, 20, and 30 g to reach target LSIs of 4, 5, 6, and 7. Lesion size and steam pops were recorded for each ablation. ResultsLesion size was positively correlated with LSI regardless of power settings (p < 0.001). The linear correlation coefficients of lesion size and LSI decreased at higher power settings. At high power combined with high CF settings (50 W/20 g), lesion depth and LSI showed an irrelevant correlation (p = 0.7855). High-power ablation shortened ablation time and increased the effect of resistive heating. LSI could predict the risk of steam pops at high-power settings with the optimal threshold of 5.65 (sensitivity, 94.1%; specificity, 46.1%). The ablation depth of the heavy heart was shallower than that of the light heart under similar ablation settings. ConclusionsLSI could predict radiofrequency lesion size and steam pops at high power settings in vitro, while synchronous high power and high CF should be avoided. Lighter hearts require relatively lower ablation settings to create appropriate ablation depth.
引用
收藏
页码:487 / 497
页数:11
相关论文
共 42 条
  • [31] Lower contact force predicts right pulmonary vein carina breakthrough after ablation index-guided pulmonary vein isolation using high-power short-duration
    Chen, Wei-Tso
    Chung, Fa-Po
    Lin, Yenn-Jiang
    Chang, Shih-Lin
    Lo, Li-Wei
    Hu, Yu-Feng
    Tuan, Ta-Chuan
    Chao, Tze-Fan
    Liao, Jo-Nan
    Lin, Chin-Yu
    Chang, Ting-Yung
    Kuo, Ling
    Wu, Cheng-, I
    Liu, Chih-Min
    Liu, Shin-Huei
    Hsieh, Yu-Cheng
    Li, Cheng-Hung
    Chen, Shih-Ann
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2024, 35 (01) : 60 - 68
  • [32] Prevalence, Predictors and Mechanisms of Steam Pops in Ablation Index-Guided High-Power Pulmonary Vein Isolation
    Shuang, Tian
    Kong, Lingcong
    Cheng, Fuyu
    Wang, Xinhua
    JOURNAL OF CARDIOVASCULAR DEVELOPMENT AND DISEASE, 2022, 9 (12)
  • [33] Incidence and predictors of thermal oesophageal and vagus nerve injuries in Ablation Index-guided high-power-short-duration ablation of atrial fibrillation: a prospective study
    Wolff, Charlotte
    Langenhan, Katharina
    Wolff, Marc
    Efimova, Elena
    Zachaeus, Markus
    Darma, Angeliki
    Dinov, Borislav
    Seewoester, Timm
    Nedios, Sotirios
    Bertagnolli, Livio
    Wolff, Jan
    Paetsch, Ingo
    Jahnke, Cosima
    Bollmann, Andreas
    Hindricks, Gerhard
    Bode, Kerstin
    Halm, Ulrich
    Arya, Arash
    EUROPACE, 2024, 26 (05):
  • [34] High-Power Short-Duration Lesion Index-Guided Posterior Wall Isolation beyond Pulmonary Vein Isolation for Persistent Atrial Fibrillation
    Conti, Sergio
    Sabatino, Francesco
    Fortunato, Fabrizio
    Ferrara, Giuliano
    Cascino, Antonio
    Sgarito, Giuseppe
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (16)
  • [35] Impact of combining ablation index-guided and very high-power short-duration ablation at posterior wall adjacent to esophagus during perioperative period on procedural factors
    Yano, Masamichi
    Egami, Yasuyuki
    Abe, Masaru
    Osuga, Mizuki
    Nohara, Hiroaki
    Kawanami, Shodai
    Ukita, Kohei
    Kawamura, Akito
    Yasumoto, Koji
    Okamoto, Naotaka
    Matsunaga-Lee, Yasuharu
    Nishino, Masami
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2025, 36 (01) : 85 - 94
  • [36] Effectiveness of first-pass pulmonary vein isolation with index-guided ablation compared to very-high-power, short-duration ablation: A retrospective single-center study
    Peller, Michal
    Dzwinacka, Julia
    Krzowski, Bartosz
    Marchel, Michal
    Maciejewski, Cezary
    Mitrzak, Karolina
    Opolski, Grzegorz
    Grabowski, Marcin
    Balsam, Pawel
    Lodzinski, Piotr
    POLISH HEART JOURNAL-KARDIOLOGIA POLSKA, 2025, 83 (01): : 35 - 42
  • [37] Safety and efficacy of intracardiac echocardiography-guided zero-fluoroscopy ablation in atrial fibrillation patients: a comparative study of high-power short-duration and low-power long-duration strategies
    Liu, Guang-an
    Shao, Bo
    Wu, Wanglong
    Zhou, Linxiao
    Cui, Jing
    Chen, Wenxue
    Zhang, Ruoxi
    Liu, Feng
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2024, 11
  • [38] Impact of weight adjusted high frequency low tidal volume ventilation and atrial pacing in lesion metrics in high-power short-duration ablation: Results of a pilot study
    Vassallo, Fabricio
    Volponi, Carlos
    Cunha, Christiano
    Corcino, Lucas
    Serpa, Eduardo
    Simoes Jr, Aloyr
    Gasparini, Dalbian
    Barbosa, Luiz Fernando
    Schmidt, Andre
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2024, 35 (05) : 975 - 983
  • [39] Efficacy and Safety of High-power Short-duration Radio Frequency Ablation in the Treatment of Atrial Fibrillation: A Meta-analysis of Prospective Study
    Ma, Guohua
    Zhang, Weijiang
    HEART SURGERY FORUM, 2024, 27 (02) : E188 - E198
  • [40] The Feasibility, Safety and Outcome of Very High-Power Short Duration Radiofrequency Ablation in Pulmonary Vein Isolation: A Real-World Observation Study
    Mavilakandy, Akash
    Koev, Ivelin
    Sidhu, Bharat
    Kotb, Ahmed
    Antoun, Ibrahim
    Man, Sharon H.
    Vali, Zakariyya
    Pooranachandran, Vivetha
    Barker, Joseph
    Panchal, Gaurav
    Li, Xin
    Ng, G. Andre
    REVIEWS IN CARDIOVASCULAR MEDICINE, 2024, 25 (07)