AAPM Task Group Report 306: Quality control and assurance for tomotherapy: An update to Task Group Report 148

被引:23
作者
Chen, Quan [1 ]
Rong, Yi [2 ]
Burmeister, Jay W. W. [3 ,4 ]
Chao, Edward H. H. [5 ]
Corradini, Nathan A. A. [6 ]
Followill, David S. S. [7 ]
Li, X. Allen [8 ]
Liu, An [9 ]
Qi, X. Sharon [10 ]
Shi, Hairong [11 ]
Smilowitz, Jennifer B. B. [12 ]
机构
[1] City Hope Med Ctr, Radiat Oncol, Duarte, CA 91010 USA
[2] Mayo Clin Hosp, Dept Radiat Oncol, Phoenix, AZ USA
[3] Gershenson ROC, Karmanos Canc Ctr, Detroit, MI USA
[4] Wayne State Univ, Dept Oncol, Sch Med, Detroit, MI USA
[5] Accuray Inc, Madison, WI USA
[6] Clin Luganese Moncucco, Radiat Oncol, Lugano, Switzerland
[7] Univ Texas MD Anderson Canc Ctr, Radiat Phys, Houston, TX USA
[8] Med Coll Wisconsin, Radiat Oncol, Milwaukee, WI USA
[9] City Hope Med Ctr, Radiat Oncol, Duarte, CA USA
[10] UCLA Sch Med, Radiat Oncol, Los Angeles, CA USA
[11] Oklahoma Canc Specialists & Res Inst, Radiat Oncol, Tulsa, OK USA
[12] Univ Wisconsin, Human Oncol & Med Phys, Madison, WI USA
关键词
quality assurance; tomotherapy; DIODE-ARRAY DOSIMETER; PORTAL DOSE IMAGES; ROTATIONAL OUTPUT VARIATION; GUIDED RADIATION-THERAPY; HIGH-ENERGY PHOTON; STEP-AND-SHOOT; HELICAL TOMOTHERAPY; FAILURE MODE; DYNAMIC JAW; ANGULAR-DEPENDENCE;
D O I
10.1002/mp.16150
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Since the publication of AAPM Task Group (TG) 148 on quality assurance (QA) for helical tomotherapy, there have been many new developments on the tomotherapy platform involving treatment delivery, on-board imaging options, motion management, and treatment planning systems (TPSs). In response to a need for guidance on quality control (QC) and QA for these technologies, the AAPM Therapy Physics Committee commissioned TG 306 to review these changes and make recommendations related to these technology updates. The specific objectives of this TG were (1) to update, as needed, recommendations on tolerance limits, frequencies and QC/QA testing methodology in TG 148, (2) address the commissioning and necessary QA checks, as a supplement to Medical Physics Practice Guidelines (MPPG) with respect to tomotherapy TPS and (3) to provide risk-based recommendations on the new technology implemented clinically and treatment delivery workflow. Detailed recommendations on QA tests and their tolerance levels are provided for dynamic jaws, binary multileaf collimators, and Synchrony motion management. A subset of TPS commissioning and QA checks in MPPG 5.a. applicable to tomotherapy are recommended. In addition, failure mode and effects analysis has been conducted among TG members to obtain multi-institutional analysis on tomotherapy-related failure modes and their effect ranking.
引用
收藏
页码:E25 / E52
页数:28
相关论文
共 139 条
[1]   AAPM's TG-51 protocol for clinical reference dosimetry of high-energy photon and electron beams [J].
Almond, PR ;
Biggs, PJ ;
Coursey, BM ;
Hanson, WF ;
Huq, MS ;
Nath, R ;
Rogers, DWO .
MEDICAL PHYSICS, 1999, 26 (09) :1847-1870
[2]  
Althof V., 2017, NEDERLANDSE COMMISSI, DOI [10.25030/ncs-027, DOI 10.25030/NCS-027]
[3]  
Anna B., 2016, PHYS MEDICA, V32, P287
[4]  
[Anonymous], 2018, DOSECHECK REF GUID
[5]  
[Anonymous], 2020, PHYS ESS GUID 106956
[6]  
[Anonymous], 2017, TQATM 2 1 10 MAN
[7]  
[Anonymous], 2015, TOMOTHERAPY TREATM S
[8]   Quality assurance for image-guided radiation therapy utilizing CT-based technologies: A report of the AAPM TG-179 [J].
Bissonnette, Jean-Pierre ;
Balter, Peter A. ;
Dong, Lei ;
Langen, Katja M. ;
Lovelock, D. Michael ;
Miften, Moyed ;
Moseley, Douglas J. ;
Pouliot, Jean ;
Sonke, Jan-Jakob ;
Yoo, Sua .
MEDICAL PHYSICS, 2012, 39 (04) :1946-1963
[9]   Experimental validation of a commercial 3D dose verification system for intensity-modulated arc therapies [J].
Boggula, Ramesh ;
Lorenz, Friedlieb ;
Mueller, Lutz ;
Birkner, Mattias ;
Wertz, Hansjoerg ;
Stieler, Florian ;
Steil, Volker ;
Lohr, Frank ;
Wenz, Frederik .
PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (19) :5619-5633
[10]   Does TomoDirect 3DCRT represent a suitable option for post-operative whole breast irradiation? A hypothesis-generating pilot study [J].
Borca, Valeria Casanova ;
Franco, Pierfrancesco ;
Catuzzo, Paola ;
Migliaccio, Fernanda ;
Zenone, Flora ;
Aimonetto, Stefania ;
Peruzzo, Andrea ;
Pasquino, Massimo ;
Russo, Giuliana ;
La Porta, Maria Rosa ;
Cante, Domenico ;
Sciacero, Piera ;
Girelli, Giuseppe ;
Ricardi, Umberto ;
Tofani, Santi .
RADIATION ONCOLOGY, 2012, 7