Verification of image quality improvement of low-count bone scintigraphy using deep learning

被引:6
|
作者
Murata, Taisuke [1 ,2 ]
Hashimoto, Takuma [1 ]
Onoguchi, Masahisa [2 ]
Shibutani, Takayuki [2 ]
Iimori, Takashi [1 ]
Sawada, Koichi [1 ]
Umezawa, Tetsuro [1 ]
Masuda, Yoshitada [1 ]
Uno, Takashi [3 ]
机构
[1] Chiba Univ Hosp, Dept Radiol, Chiba 2608677, Japan
[2] Kanazawa Univ, Grad Sch Med Sci, Dept Quantum Med Technol, 5-11-80 Kodatsuno, Kanazawa, Ishikawa 9200942, Japan
[3] Chiba Univ, Grad Sch Med, Dept Diagnost Radiol & Radiat Oncol, Chiba, Japan
关键词
Deep learning; Bone scintigraphy; Whole-body image; Noise reduction; Diagnostic performance; ARTIFICIAL-INTELLIGENCE; SCAN;
D O I
10.1007/s12194-023-00776-5
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To improve image quality for low-count bone scintigraphy using deep learning and evaluate their clinical applicability. Six hundred patients (training, 500; validation, 50; evaluation, 50) were included in this study. Low-count original images (75%, 50%, 25%, 10%, and 5% counts) were generated from reference images (100% counts) using Poisson resampling. Output (DL-filtered) images were obtained after training with U-Net using reference images as teacher data. Gaussian-filtered images were generated for comparison. Peak signal-to-noise ratio (PSNR) and structural similarity (SSIM) to the reference image were calculated to determine image quality. Artificial neural network (ANN) value, bone scan index (BSI), and number of hotspots (Hs) were computed using BONENAVI analysis to assess diagnostic performance. Accuracy of bone metastasis detection and area under the curve (AUC) were calculated. PSNR and SSIM for DL-filtered images were highest in all count percentages. BONENAVI analysis values for DL-filtered images did not differ significantly, regardless of the presence or absence of bone metastases. BONENAVI analysis values for original and Gaussian-filtered images differed significantly at <= 25% counts in patients without bone metastases. In patients with bone metastases, BSI and Hs for original and Gaussian-filtered images differed significantly at <= 10% counts, whereas ANN values did not. The accuracy of bone metastasis detection was highest for DL-filtered images in all count percentages; the AUC did not differ significantly. The deep learning method improved image quality and bone metastasis detection accuracy for low-count bone scintigraphy, suggesting its clinical applicability.
引用
收藏
页码:269 / 279
页数:11
相关论文
共 50 条
  • [21] A Deep ADMM-net for iterative low-count PET reconstruction
    Li, Yingying
    Li, Jun
    Liu, HuaFeng
    OPTICS IN HEALTH CARE AND BIOMEDICAL OPTICS X, 2020, 11553
  • [22] Optimal Inversion of the Anscombe Transformation in Low-Count Poisson Image Denoising
    Makitalo, Markku
    Foi, Alessandro
    IEEE TRANSACTIONS ON IMAGE PROCESSING, 2011, 20 (01) : 99 - 109
  • [23] Nearly Exact Discrepancy Principle for Low-Count Poisson Image Restoration
    Bevilacqua, Francesca
    Lanza, Alessandro
    Pragliola, Monica
    Sgallari, Fiorella
    JOURNAL OF IMAGING, 2022, 8 (01)
  • [24] Systematic infrared image quality improvement using deep learning based techniques
    Zhang, Huaizhong
    Casaseca-de-la-Higuera, Pablo
    Luo, Chunbo
    Wang, Qi
    Kitchin, Matthew
    Parmley, Andrew
    Monge-Alvarez, Jesus
    REMOTE SENSING TECHNOLOGIES AND APPLICATIONS IN URBAN ENVIRONMENTS, 2016, 10008
  • [25] Image Quality Improvement in Cone-Beam CT Using Deep Learning
    Lei, Yang
    Wang, Tonghe
    Harms, Joseph
    Shafai-Erfani, Ghazal
    Dong, Xue
    Zhou, Jun
    Patel, Pretesh
    Tang, Xiangyang
    Liu, Tian
    Curran, Walter J.
    Higgins, Kristin
    Yang, Xiaofeng
    MEDICAL IMAGING 2019: PHYSICS OF MEDICAL IMAGING, 2019, 10948
  • [26] Denoising method for image quality improvement in photoacoustic microscopy using deep learning
    Yu, Ziming
    Tang, Kanggao
    Song, Xianlin
    COMPUTATIONAL OPTICS 2021, 2021, 11875
  • [27] Cardiac Amyloidosis Screening using Deep Learning on Bone Scintigraphy
    Spielvogel, Clemens P.
    Haberl, David
    Ning, Jing
    Kluge, Kilian
    Li, Xiang
    Ma, Xiaowei
    Zhao, Min
    Calabretta, Raffaella
    Hacker, Marcus
    Nitsche, Christian
    JOURNAL OF NUCLEAR MEDICINE, 2024, 65
  • [28] REPLY: Deep Learning on Bone Scintigraphy
    Delbarre, Marc-Antoine
    Girardon, Francois
    Damy, Thibaud
    JACC-CARDIOVASCULAR IMAGING, 2023, 16 (08) : 1125 - 1125
  • [29] Optimizing Low-Count PET Image Quality: A Comparative Study of Unsupervised Denoising Methods with Novel Cost Functions
    Zhao, Tianyun
    Huang, Chuan
    JOURNAL OF NUCLEAR MEDICINE, 2024, 65
  • [30] Author Correction: Low-count whole-body PET with deep learning in a multicenter and externally validated study
    Akshay S. Chaudhari
    Erik Mittra
    Guido A. Davidzon
    Praveen Gulaka
    Harsh Gandhi
    Adam Brown
    Tao Zhang
    Shyam Srinivas
    Enhao Gong
    Greg Zaharchuk
    Hossein Jadvar
    npj Digital Medicine, 4