Radiation exposure assessment of nuclear medicine staff administering [177Lu]Lu-DOTA-TATE with active and passive dosimetry

被引:3
|
作者
Riveira-Martin, Mercedes [1 ,2 ]
Struelens, Lara [3 ]
Iglesias, Jose Munoz [4 ]
Schoonjans, Werner [3 ]
Tabuenca, Olga [4 ]
Nogueiras, Jose Manuel [5 ]
Gomez, Francisco Javier Salvador [6 ]
Medina, Antonio Lopez [6 ,7 ]
机构
[1] Galicia Hlth Res Inst IISGS, Genet Oncol Radiobiol & Radiointeract Res Grp, Vigo, Spain
[2] Univ Complutense Madrid, Med Sch, Dept Radiol Rehabil & Physiotherapy, Madrid, Spain
[3] Belgian Nucl Res Ctr SCK CEN, Mol, Belgium
[4] Univ Hosp Vigo, Meixoeiro Hosp, Nucl Med Dept SERGAS, Vigo, Spain
[5] Univ Hosp Vigo, Meixoeiro Hosp, Nucl Med Dept GALARIA, Vigo, Spain
[6] Univ Hosp Vigo, Meixoeiro Hosp, Med Phys & RP Dept GALARIA, Vigo, Spain
[7] Univ Vigo, Dept Funct Biol & Hlth Sci, Vigo, Spain
关键词
Lu-177]Lu-DOTA-TATE; Occupational exposure; Nuclear medicine; Equivalent dose; RECEPTOR RADIONUCLIDE THERAPY; NEUROENDOCRINE TUMORS; LU-177; SAFETY; LU-177-DOTATATE; LU-177-OCTREOTATE;
D O I
10.1186/s40658-023-00592-1
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: The use of lutetium-177 (Lu-177)-based radiopharmaceuticals in peptide receptor nuclear therapy is increasing, but so is the number of nuclear medicine workers exposed to higher levels of radiation. In recent years, [Lu-177]Lu-DOTA-TATE has begun to be widely used for the treatment of neuroendocrine tumours. However, there are few studies evaluating the occupational radiation exposure during its administration, and there are still some challenges that can result in higher doses to the staff, such as a lack of trained personnel or fully standardised procedures. In response, this study aims to provide a comprehensive analysis of occupational doses to the staff involved in the administration of [Lu-177]Lu-DOTA-TATE.Results: A total of 32 administrations of [Lu-177]Lu-DOTA-TATE (7.4 GBq/session) carried out by a physician and a nurse, were studied. In total, two physicians and four nurses were independently monitored with cumulative (passive) and/or real-time (active) dosemeters. Extremity, eye lens and whole-body doses were evaluated in terms of the dosimetric quantities Hp(0.07), Hp(3) and Hp(10), respectively. It was obtained that lead aprons reduced dose rates and whole-body doses by 71% and 69% for the physicians, respectively, and by 56% and 68% for the nurses. On average, normalised Hp(10) values of 0.65 +/- 0.18 mu Sv/GBq were obtained with active dosimetry, which is generally consistent with passive dosemeters. For physicians, the median of the maximum normalised Hp(0.07) values was 41.5 mu Sv/GBq on the non-dominant hand and 45.2 mu Sv/GBq on the dominant hand. For nurses 15.4 mu Sv/GBq on the non-dominant and 13.9 mu Sv/GBq on the dominant hand. The ratio or correction factor between the maximum dose measured on the hand and the dose measured on the base of the middle/ring finger of the non-dominant hand resulted in a factor of 5/6 for the physicians and 3/4 for the nurses. Finally, maximum normalised Hp(3) doses resulted in 2.02 mu Sv/GBq for physicians and 1.76 mu Sv/GBq for nurses.Conclusions: If appropriate safety measures are taken, the administration of [Lu-177]Lu-DOTA-TATE is a safe procedure for workers. However, regular monitoring is recommended to ensure that the annual dose limits are not exceeded.
引用
收藏
页数:25
相关论文
共 39 条
  • [31] Recovery of 177Lu from Irradiated HfO2 Targets for Nuclear Medicine Purposes
    Kazakov, Andrey G.
    Ekatova, Taisya Y.
    Babenya, Julia S.
    Belyshev, Sergey S.
    Khankin, Vadim V.
    Kuznetsov, Alexander A.
    Vinokurov, Sergey E.
    Myasoedov, Boris F.
    MOLECULES, 2022, 27 (10):
  • [32] Availability of both [177Lu]Lu-DOTA-TATE and [90Y]Y-DOTATATE as PRRT agents for neuroendocrine tumors: can we evolve a rational sequential duo-PRRT protocol for large volume resistant tumors?
    Basu, Sandip
    Parghane, Rahul V.
    Banerjee, Sharmila
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2020, 47 (04) : 756 - 758
  • [33] Effectiveness of radiation protectors to reduce occupational radiation dose of medical staff when performing radioligand therapy with 177Lu
    Inoue, Saya
    Asahara, Takashi
    Hasegawa, Daisuke
    Yoshitomi, Keisuke
    Goto, Sota
    Hayashi, Hiroaki
    Iguchi, Toshihiro
    RADIATION PHYSICS AND CHEMISTRY, 2025, 235
  • [34] Incorporation Monitoring of Staff using I-131 and Lu-177 in a Nuclear Medicine Ward
    Wanke, Carsten
    Szemerski, Bastian
    Geworski, Lilli
    NUKLEARMEDIZIN-NUCLEAR MEDICINE, 2022, 61 (04): : 333 - 338
  • [35] How much do 68Ga-, 177Lu- and 131I-based radiopharmaceuticals contribute to the global radiation exposure of nuclear medicine staff?
    Struelens, L.
    Aalbersberg, E.
    Beels, L.
    Cherbuin, N.
    D'Asseler, Y.
    De Monte, F.
    Lopez Medina, A.
    del Carmen Riveira Martin, M.
    Schoonjans, W.
    Terwinghe, C.
    Van den Block, S.
    Vanhavere, F.
    Zaidi, H.
    Schelfhout, V.
    EJNMMI PHYSICS, 2024, 11 (01):
  • [36] Evaluation of Safety, Biodistribution, and Dosimetry of a Long-Acting Radiolabeled Somatostatin Analog 177Lu-DOTA-EB-TATE With and Without Amino Acid Infusion
    Jiang, Yuanyuan
    Liu, Qingxing
    Wang, Guochang
    Zhang, Jingjing
    Zhu, Zhaohui
    Chen, Xiaoyuan
    CLINICAL NUCLEAR MEDICINE, 2023, 48 (06) : E289 - E293
  • [37] Safety, Pharmacokinetics, and Dosimetry of a Long-Acting Radiolabeled Somatostatin Analog 177Lu-DOTA-EB-TATE in Patients with Advanced Metastatic Neuroendocrine Tumors
    Zhang, Jingjing
    Wang, Hao
    Jacobson, Orit
    Cheng, Yuejuan
    Niu, Gang
    Li, Fang
    Bai, Chunmei
    Zhu, Zhaohui
    Chen, Xiaoyuan
    JOURNAL OF NUCLEAR MEDICINE, 2018, 59 (11) : 1699 - 1705
  • [38] Super-selective hepatic arterial infusions as established technique ('ARETAIEION' Protocol) of [177Lu]DOTA-TATE in inoperable neuroendocrine liver metastases of gastro-entero-pancreatic (GEP) tumors
    Limouris, G. S.
    Karfis, I.
    Chatzioannou, A.
    Paphiti, M. I.
    Lyra, M.
    Gennatas, K.
    Nikou, G.
    Voros, D.
    Pragulidis, G. P.
    Polydorou, A. A.
    Gouliamos, A.
    QUARTERLY JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2012, 56 (06) : 551 - 558
  • [39] A Monte Carlo approach to small-scale dosimetry of solid tumour microvasculature for nuclear medicine therapies with 223Ra-, 131I-, 177Lu- and 111In-labelled radiopharmaceuticals
    Amato, Ernesto
    Leotta, Salvatore
    Italiano, Antonio
    Baldari, Sergio
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2015, 31 (05): : 536 - 541