Impact of Scleral Lens Front Surface Eccentricity on Visual Acuity, Contrast Sensitivity, and Higher-Order Aberrations in Eyes With Keratoconus

被引:1
作者
Badrinarayanan, Aparna [1 ]
Balakrishnan, Akshaya C. [1 ]
Dutta, Ronit [1 ]
Kumar, R. Mahesh [1 ]
Iqbal, Asif [1 ,2 ]
机构
[1] Sankara Nethralaya, Unit Med Res Fdn, Dept Contact Lens, Chennai, India
[2] Sankara Nethralaya Med Res Fdn, Dept Contact Lens, 18,Coll Rd, Chennai 600006, Tamilnadu, India
来源
EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE | 2023年 / 49卷 / 09期
关键词
Scleral lens; Keratoconus; Front surface eccentricity; Higher-order aberration; Visual acuity; Contrast sensitivity; CORNEAL TOPOGRAPHY; CLINICAL-OUTCOMES; REHABILITATION; ASPHERICITY; ANTERIOR;
D O I
10.1097/ICL.0000000000001007
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To investigate the effect of front surface eccentricity (FSE) of scleral lenses (SLs) on corrected distance visual acuity (CDVA), contrast sensitivity (CS), and higher-order aberrations (HOAs) in keratoconic eyes.Methods: Fifteen keratoconic eyes fitted with BostonSight SCLERAL lenses of different eccentricity values (FSE0=0, FSE1=0.30, and FSE2=0.60). CDVA, CS, and HOAs were measured at baseline and after 30 min of SL wear. CDVA and CS were measured with the Early Treatment Diabetic Retinopathy Study and Pelli-Robson chart, respectively, and iTrace aberrometer was used to evaluate the HOAs.Results: Baseline CDVA was 0.30 +/- 0.29, which significantly improved to 0.10 +/- 0.11, 0.05 +/- 0.06, and 0.05 +/- 0.08 logMAR with FSE0, FSE1, and FSE2, respectively (P<0.05). The post hoc showed no significant difference between eccentricities. Baseline CS was 1.19 +/- 0.47, which improved to 1.54 +/- 0.12, 1.59 +/- 0.10, and 1.60 +/- 0.11 with FSE0, FSE1, and FSE2, respectively (P<0.01), but post hoc showed no significant difference between eccentricities. A statistically significant reduction was found in HOAs when compared with baseline (P<0.01). Comparison between eccentricities showed a significant difference only between FSE0 and FSE1 for RMS coma (P=0.01) and RMS spherical aberrations (P=0.004) where FSE1 showed better performance in reducing HOAs compared with FSE0. HO-RMS, RMS secondary astigmatism, and RMS trefoil showed no significant difference between eccentricities, but FSE1 and FSE2 performed superior to FSE0.Conclusion: BostonSight SCLERAL lenses with varying eccentricities corrected a significant amount of HOAs and improved CDVA and CS in keratoconus patients. Practitioners should be aware of this distinct feature of SLs and use it as needed to improve visual performance.
引用
收藏
页码:374 / 378
页数:5
相关论文
共 35 条
  • [1] Clinical outcomes of scleral Misa lenses for visual rehabilitation in patients with pellucid marginal degeneration
    Asena, Leyla
    Altinors, Dilek Dursun
    [J]. CONTACT LENS & ANTERIOR EYE, 2016, 39 (06) : 420 - 424
  • [2] Peripheral Ocular Aberrations in Mild and Moderate Keratoconus
    Atchison, David A.
    Mathur, Ankit
    Read, Scott A.
    Walker, Mitchell I.
    Newman, Alexander R.
    Tanos, Photios P.
    McLennan, Roderick T.
    Tran, Andrew H.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (12) : 6850 - 6857
  • [3] Fluid reservoir thickness and aberration relationship in keratoconic eyes with scleral lenses
    Balakrishnan, Akshaya C.
    Badrinarayanan, Aparna
    Sivaraman, Viswanathan
    Kumar, Ramar Mahesh
    Iqbal, Asif
    [J]. OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2022, 42 (01) : 178 - 184
  • [4] Clinical Outcomes of Scleral Lens Fitting with a Data-driven, Quadrant-specific Design: Multicenter Review
    Barnett, Melissa
    Carrasquillo, Karen G.
    Schornack, Muriel M.
    [J]. OPTOMETRY AND VISION SCIENCE, 2020, 97 (09) : 761 - 765
  • [5] MATHEMATICAL-MODELS OF THE GENERAL CORNEAL SURFACE
    BUREK, H
    DOUTHWAITE, WA
    [J]. OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 1993, 13 (01) : 68 - 72
  • [6] Posterior Corneal Aberrations and Their Compensation Effects on Anterior Corneal Aberrations in Keratoconic Eyes
    Chen, Minghan
    Yoon, Geunyoung
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2008, 49 (12) : 5645 - 5652
  • [7] Irregular Corneas: Improve Visual Function With Scleral Contact Lenses
    de Luis Eguileor, Beatriz
    Etxebarria Ecenarro, Jaime
    Santamaria Carro, Alaitz
    Feijoo Lera, Raquel
    [J]. EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2018, 44 (03): : 159 - 163
  • [8] DECUNHA DA, 1993, OPHTHAL PHYSL OPT, V13, P377, DOI 10.1111/j.1475-1313.1993.tb00494.x
  • [9] The asphericity, curvature and tilt of the human cornea measured using a videokeratoscope
    Douthwaite, WA
    [J]. OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2003, 23 (02) : 141 - 150
  • [10] Calculated impact of higher-order monochromatic aberrations on retinal image quality in a population of human eyes (vol 19, pg 1, 2002)
    Guirao, A
    Porter, J
    Williams, DR
    Cox, IG
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2002, 19 (03) : 620 - 628