A Passive Noise Attenuation Earplug Designed to Minimise Unwanted Air Turbine Driven High-Speed Dental Drill Noise

被引:3
作者
Jiang, Pingfei [1 ]
Atherton, Mark A. [2 ]
Millar, Brian J. [3 ]
机构
[1] Brunel Univ, Dept Mech & Aerosp Engn, London, England
[2] Brunel Univ, Dept Mech & Aerosp Engn, Mech Engn, London, England
[3] Kings Coll London, Fac Dent & Oral & Craniofacial Sci, London, England
关键词
Additive Manufacturing; Passive Noise Reduction; Dental Drill Noise; High Frequency Noise; Quarter Wavelength Resonator; THRESHOLDS; CAPACITY; SOUND;
D O I
10.1922/EJPRD_2463Jiang16
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction: Air turbine dental drill noise contains high-frequency components that are of concern for patients and dental staff. Meanwhile, verbal communication between the dentist and patient is essential. Conventional active noise-cancelling headphones are ineffective for dental drill noise and simply suppress all sound and hinder communication. Method: A compact passive earplug device was designed specifically to attenuate broadband high-frequency noise ranges from 5 to 8 kHz employing an array of quarter wavelength (QW) resonators. This device was 3D printed and tested against white noise to enhance the objectivity of analysis, using a calibrated ear and cheek simulator to effectively measure its performance. Results: The results showed that the resonators produced an average reduction of 27 dB across the targeted frequency range. When compared with two proprietary passive earplugs, this developed passive device prototype was able to attenuate an average of 9 dB more across the target frequency range whilst delivering louder speech signals of 14 dB more. The results also show that using an array of resonators exhibits an accumulated effect of individual resonator performance. Conclusions: This low-cost passive device could have a place in the dental clinic to reduce unwanted drill noise equivalent to the white noise high frequency spectra tested.
引用
收藏
页码:262 / 277
页数:16
相关论文
共 52 条
[41]  
Sorainen E, 2002, AIHAJ, V63, P231, DOI 10.1080/15428110208984709
[42]   On Optimal Frequency-Domain Multichannel Linear Filtering for Noise Reduction [J].
Souden, Mehrez ;
Benesty, Jacob ;
Affes, Sofiene .
IEEE TRANSACTIONS ON AUDIO SPEECH AND LANGUAGE PROCESSING, 2010, 18 (02) :260-276
[43]  
Stepien K., 2014, Medtube Science, V2, P21
[44]   Evaluation by industrial workers of passive and level-dependent hearing protection devices [J].
Tufts, Jennifer B. ;
Hamilton, Mark A. ;
Ucci, Amanda J. ;
Rubas, James .
NOISE & HEALTH, 2011, 13 (50) :26-36
[45]  
Wagner N., 2012, NAFEMS SEM GEN PROP, P1
[46]   Open Versus Closed Hearing-Aid Fittings: A Literature Review of Both Fitting Approaches [J].
Winkler, Alexandra ;
Latzel, Matthias ;
Holube, Inga .
TRENDS IN HEARING, 2016, 20
[47]   A four-part setting on examining the anxiety-provoking capacity of the sound of dental equipment [J].
Wong, Hai Ming ;
Mak, Cheuk Ming ;
Xu, Ying Feng .
NOISE & HEALTH, 2011, 13 (55) :385-391
[48]   Modeling and experimental verification of a new muffler based on the theory of quarter-wavelength tube and the Helmholtz muffler [J].
Wu, Can ;
Chen, Lei ;
Ni, Jing ;
Xu, Jing .
SPRINGERPLUS, 2016, 5
[49]  
Yamada T., INTERNOISE 2014 43 I, P1
[50]   Implications for Bone Conduction Mechanisms from Thresholds of Post Radical Mastoidectomy and Subtotal Petrosectomy Patients [J].
Yehezkely, Michal Kaufmann ;
Grinblat, Golda ;
Dor, Miriam Geal ;
Chordekar, Shai ;
Perez, Ronen ;
Adelman, Cahtia ;
Sohmer, Haim .
JOURNAL OF INTERNATIONAL ADVANCED OTOLOGY, 2019, 15 (01) :8-11