Multiperson Respiratory Monitoring Using Single-Channel Continuous-Wave Radar With Time Modulated Array

被引:5
作者
Guan, Lei [1 ]
Wu, Tong [2 ]
Yang, Xiaodong [1 ]
Zhao, Nan [1 ]
Zhang, Zhiya [3 ]
Alomainy, Akram [4 ]
Imran, Muhammad Ali [5 ]
Abbasi, Qammer H. [5 ]
机构
[1] Xidian Univ, Sch Elect Engn, Key Lab High Speed Circuit Design & EMC, Minist Educ, Xian 710071, Shaanxi, Peoples R China
[2] Xidian Univ, Sch Elect Engn, Xian 710071, Shaanxi, Peoples R China
[3] Xidian Univ, Natl Key Lab Sci & Technol Microwave & Antenna, Xian 710071, Shaanxi, Peoples R China
[4] Queen Mary Univ London, Sch Elect Engn & Comp Sci, London E1 4NS, England
[5] Univ Glasgow, James Watt Sch Engn, Glasgow G12 8QQ, Scotland
基金
中国国家自然科学基金;
关键词
Multiperson; respiratory monitoring; time mod-ulated array (TMA); VITAL-SIGN; HEART-RATE; LOCALIZATION;
D O I
10.1109/TIM.2023.3287258
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Radio frequency (RF) signals are widely used in respiratory detection due to their non-contact, remote sensing advantages. In order to satisfy multiperson monitoring, the existing RF sensing system greatly increases the complexity of the feeder network, which will affect the stability of the system and have high maintenance costs. In this study, we propose a single-channel, low-complexity multiperson respiratory monitoring system. It uses a time-modulated array (TMA) to detect the position and respiration rate of multiple targets. The TMA is reconstructed into a conventional multichannel array by the harmonic recovery method. Beamforming is used to scan the scene horizontally. At the same time, the beamformed signal is converted to the frequency domain to construct the angle of arrival-frequency map (AFM). By forming a beam pointing to the target, the time domain respiration signal of each target can be acquired. The experimental results show that the maximum respiratory rate (RR) estimation errors of the proposed system in single-person, two-person, and three-person scenarios are 0.77, 0.96, and 1.32 bmp, respectively. In addition, the Bland-Altman analysis shows that our system has good consistency with the reference sensor.
引用
收藏
页数:11
相关论文
共 48 条
  • [1] An experimental study: Detecting the respiration rates of multiple stationary human targets by stepped frequency continuous wave radar
    Acar, Yunus Emre
    Saritas, Ismail
    Yaldiz, Ercan
    [J]. MEASUREMENT, 2021, 167
  • [2] Smart Homes that Monitor Breathing and Heart Rate
    Adib, Fadel
    Mao, Hongzi
    Kabelac, Zachary
    Katabi, Dina
    Miller, Robert C.
    [J]. CHI 2015: PROCEEDINGS OF THE 33RD ANNUAL CHI CONFERENCE ON HUMAN FACTORS IN COMPUTING SYSTEMS, 2015, : 837 - 846
  • [3] A New Measurement Method Based on Music Algorithm for Through-the-Wall Detection of Life Signs
    Ascione, Marcello
    Buonanno, Aniello
    D'Urso, Michele
    Angrisani, Leopoldo
    Lo Moriello, Rosario Schiano
    [J]. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2013, 62 (01) : 13 - 26
  • [4] TR-BREATH: Time-Reversal Breathing Rate Estimation and Detection
    Chen, Chen
    Han, Yi
    Chen, Yan
    Hung-Quoc Lai
    Zhang, Feng
    Wang, Beibei
    Liu, K. J. Ray
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2018, 65 (03) : 489 - 501
  • [5] Chen WC, 2021, PROC EUR CONF ANTENN
  • [6] Vital Signs Identification System With Doppler Radars and Thermal Camera
    Chian, De-Ming
    Wen, Chao-Kai
    Wang, Chang-Jen
    Hsu, Ming-Huan
    Wang, Fu-Kang
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, 2022, 16 (01) : 153 - 167
  • [7] A Non-Contact Detection Method for Multi-Person Vital Signs Based on IR-UWB Radar
    Dang, Xiaochao
    Zhang, Jinlong
    Hao, Zhanjun
    [J]. SENSORS, 2022, 22 (16)
  • [8] Design and Implementation of a Noncontact Sleep Monitoring System Using Infrared Cameras and Motion Sensor
    Deng, Fei
    Dong, Jianwu
    Wang, Xiangyu
    Fang, Ying
    Liu, Yu
    Yu, Zhaofei
    Liu, Jing
    Chen, Feng
    [J]. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2018, 67 (07) : 1555 - 1563
  • [9] Simultaneous Detection of Multi-Target Vital Signs Using EEMD Algorithm Based on FMCW Radar
    Fang, Guan-Wei
    Huang, Ching-Yao
    Yang, Chin-Lung
    [J]. 2019 IEEE MTT-S INTERNATIONAL MICROWAVE BIOMEDICAL CONFERENCE (IMBIOC 2019), 2019,
  • [10] Multitarget Vital Signs Measurement With Chest Motion Imaging Based on MIMO Radar
    Feng, Chen
    Jiang, Xiaonan
    Jeong, Min-Gyo
    Hong, Hong
    Fu, Chang-Hong
    Yang, Xiaohui
    Wang, E.
    Zhu, Xiaohua
    Liu, Xiaoguang
    [J]. IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2021, 69 (11) : 4735 - 4747