Phased Array System for Damage Detection in Plate-Like Structures Based on Single Lamb Wave Mode Extraction

被引:2
作者
Yang, Zhengyan [1 ]
Zhang, Jiaqi [2 ]
Xu, Hao [2 ]
Yang, Lei [2 ]
Ma, Shuyi [3 ]
Wu, Zhanjun [2 ]
机构
[1] Dalian Maritime Univ, Coll Transportat Engn, Dalian 116024, Peoples R China
[2] Dalian Univ Technol, State Key Lab Struct Anal Ind Equipment, Dalian 116024, Peoples R China
[3] Dalian Univ Sci & Technol, Dalian 116052, Peoples R China
基金
中国国家自然科学基金;
关键词
Structural health monitoring (SHM); Lamb wave; Phased array; Single mode wave extraction; Piezoelectric active transducer; WAFER ACTIVE SENSORS; GUIDED-WAVES; GENERATION; INSPECTION; DEFECTS;
D O I
10.1061/JAEEEZ.ASENG-4543
中图分类号
V [航空、航天];
学科分类号
08 ; 0825 ;
摘要
Large-scale plate-like structural components have been widely used in engineering fields. The occurrence and accumulation of structural damage will threaten the integrity of plate-like structures. Guided wave-based structural health monitoring (SHM) technology has been demonstrated as an effective tool to detect small-scale damage at a high sensitivity. Due to the advantages of baseline-free, concentrated sensor arrays and rapid inspection of the full area, Lamb wave-phased array SHM systems have been extensively investigated in recent years. However, the inherent multi-mode characteristic of Lamb waves is well-known to have a significant influence on wave propagation and further development of phased array method. In this study, a single Lamb wave mode extraction method combined with phased array SHM system is proposed based on a concentric piezoelectric active transducer (CPAT). First, a brief review of a Lamb wave-phased array system is presented, including working principle, sensor array, and Lamb wave excitation and sensing. Then, the single mode wave extraction method is performed based on the CPAT. The effectiveness of the single mode wave extraction-based phased array SHM system is first examined numerically. Finally, the proposed phased array system is used to monitor large plate-like structures and the availability and validity of the proposed SHM system is confirmed by an experimental study. This work provides an effective and practical tool to detect damage in large-scale plate-like structures.
引用
收藏
页数:11
相关论文
共 48 条
[1]   Experimental study of phased array beam steering characteristics [J].
Clay, AC ;
Wooh, SC ;
Azar, L ;
Wang, JY .
JOURNAL OF NONDESTRUCTIVE EVALUATION, 1999, 18 (02) :59-71
[2]  
Deutsch WAK, 1997, RES NONDESTRUCT EVAL, V9, P81, DOI 10.1080/09349849709409609
[3]   Direction of arrival estimation of Lamb waves using circular arrays [J].
Engholm, Marcus ;
Stepinski, Tadeusz .
STRUCTURAL HEALTH MONITORING-AN INTERNATIONAL JOURNAL, 2011, 10 (05) :467-480
[4]   Hidden corrosion detection using laser ultrasonic guided waves with multi-frequency local wavenumber estimation [J].
Gao, Tianfang ;
Sun, Hu ;
Hong, Yongqiang ;
Qing, Xinlin .
ULTRASONICS, 2020, 108 (108)
[5]  
Giurgiutiu V, 2005, J INTEL MAT SYST STR, V16, P291, DOI 10.1177/1045389X05050106
[6]   Embedded-ultrasonics structural radar for in situ structural health monitoring of thin-wall structures [J].
Giurgiutiu, V ;
Bao, J .
STRUCTURAL HEALTH MONITORING-AN INTERNATIONAL JOURNAL, 2004, 3 (02) :121-140
[7]   Selective Lamb mode excitation by piezoelectric coaxial ring actuators [J].
Glushkov, E. V. ;
Glushkova, N. V. ;
Kvasha, O. V. ;
Lammering, R. .
SMART MATERIALS AND STRUCTURES, 2010, 19 (03)
[8]   EMAT generation and laser detection of single lamb wave modes [J].
Guo, ZQ ;
Achenbach, JD ;
Krishnaswamy, S .
ULTRASONICS, 1997, 35 (06) :423-429
[9]   A high-resolution structural health monitoring system based on SH wave piezoelectric transducers phased array [J].
Huan, Qiang ;
Chen, Mingtong ;
Su, Zhongqing ;
Li, Faxin .
ULTRASONICS, 2019, 97 :29-37
[10]   Guided Wave Beamsteering using MFC Phased Arrays for Structural Health Monitoring: Analysis and Experiment [J].
Kim, Daewon ;
Philen, Michael .
JOURNAL OF INTELLIGENT MATERIAL SYSTEMS AND STRUCTURES, 2010, 21 (10) :1011-1024