Detection of Myocardial Infarction From 12-Lead ECG Trace Images Using Eigendomain Deep Representation Learning

被引:8
|
作者
Bhaskarpandit, Sathvik [1 ]
Gade, Anurag [1 ]
Dash, Shaswati [1 ]
Dash, Dinesh Kumar [2 ]
Tripathy, Rajesh Kumar [1 ]
Pachori, Ram Bilas [3 ]
机构
[1] BITS Pilani, Dept EEE, Hyderabad Campus, Hyderabad 500078, India
[2] Parala Maharaja Engn Coll, Dept Elect & Telecommun Engn, Berhampur 761003, India
[3] Indian Inst Technol Indore, Dept Elect Engn, Indore 453552, India
关键词
Electrocardiography; Lead; Diseases; Recording; Feature extraction; Representation learning; Transfer learning; 12-Lead electrocardiogram (ECG) trace image; deep learning (DL); eigendomain analysis; myocardial infarction (MI); performance evaluation; ELECTROCARDIOGRAMS; CLASSIFICATION; LOCALIZATION; NETWORK; SIGNALS;
D O I
10.1109/TIM.2023.3241986
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Myocardial infarction (MI) is a life-debilitating emergency in which there is a lack of blood flow in the heart muscle, resulting in permanent damage to the myocardium and sudden cardiac death. The 12-lead electrocardiogram (ECG) is a standardized diagnostic test conducted in hospitals to detect and localize MI-based heart disease. To diagnose MI, the cardiologist visualizes the alternations in the patterns of the 12-lead-based ECG trace image. The automated detection of MI from the 12-lead-based ECG trace image using artificial intelligence (AI)-based approaches is important in the clinical study for the accurate diagnosis of MI disease. This article proposes a novel eigendomain-based deep representation learning (DRL) approach to automatically detect MI using 12-lead ECG trace images. The singular value decomposition (SVD) and eigendomain grouping are used to evaluate five modes or components from the 12-lead ECG trace image. The EfficientNetV2B2-based transfer learning model extracts feature maps from the 12-lead ECG trace image and all five modes. The global average pooling (GAP), batch normalization (BN), dropout, and soft-max layers are used for each feature map to obtain the probability scores. The concatenated probability scores of all the feature maps, followed by the dense layer and output layer, are used to detect MI. A public database containing the 12-lead ECG trace images is used to evaluate the performance of the proposed approach. The results show that for the MI class, the proposed approach has achieved the accuracy value of 100%. Similarly, for normal versus MI versus other cardiac-arrhythmia-based disease classification schemes, the proposed approach has obtained the overall accuracy, F1-score, specificity, and sensitivity values of 99.03%, 99.01%, 99.49%, and 98.96%, respectively using fivefold cross-validation (CV). The suggested approach has demonstrated higher overall accuracy than 24 existing transfer-learning-based models to detect MI using the 12-lead ECG trace images.
引用
收藏
页数:12
相关论文
共 50 条
  • [11] VECTORCARDIOGRAM MORE SENSITIVE THAN 12-LEAD ECG IN THE DETECTION OF INFERIOR MYOCARDIAL-INFARCTION
    EDENBRANDT, L
    PAHLM, O
    LYTTKENS, K
    ALBRECHTSSON, U
    CLINICAL PHYSIOLOGY, 1990, 10 (06): : 551 - 559
  • [12] Image based deep learning in 12-lead ECG diagnosis
    Ao, Raymond
    He, George
    FRONTIERS IN ARTIFICIAL INTELLIGENCE, 2023, 5
  • [13] Lightweight Optimization of Deep Learning Models for Accurate Arrhythmia Detection in Clinical 12-Lead ECG Data
    Liu, Yunqing
    Qin, Chengjin
    Tian, Yuanyuan
    Wang, Mengxiao
    Liu, Jinlei
    Jin, Yanrui
    Li, Zhiyuan
    Zhao, Liqun
    Liu, Chengliang
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2024, 73
  • [14] Universal 12-lead ECG representation for signal denoising and cardiovascular disease detection by fusing generative and contrastive learning
    Shi, Jiguang
    Liu, Wenhan
    Zhang, Huaicheng
    Li, Zhoutong
    Chang, Sheng
    Wang, Hao
    He, Jin
    Huang, Qijun
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2024, 94
  • [15] A Lightweight Method of Myocardial Infarction Detection and Localization From Single Lead ECG Features Using Machine Learning Approach
    Anwar, Sk. Md. Shafique
    Pal, Debasmita
    Mukhopadhyay, Sumitra
    Gupta, Rajarshi
    IEEE SENSORS LETTERS, 2024, 8 (04) : 1 - 4
  • [16] Identification of the culprit artery in inferior myocardial infarction through the 12-lead ECG
    Ruiz-Mateos, Borja
    Garcia-Borbolla, Rafael
    Nunez-Gil, Ivan
    Almendro-Delia, Manuel
    Vivas, David
    Seoane-Garcia, Tania
    Cristo-Ropero, Maria J.
    Izquierdo-Bajo, Alvaro
    Madrona-Jimenez, Luis
    Fernandez-Ortiz, Antonio
    Hidalgo-Urbano, Rafael
    Ibanez, Borja
    Garcia-Rubira, Juan C.
    CORONARY ARTERY DISEASE, 2020, 31 (01) : 20 - 26
  • [17] Acute myocardial infarction detected in the 12-lead ECG by artificial neural networks
    Heden, B
    Ohlin, H
    Rittner, R
    Edenbrandt, L
    CIRCULATION, 1997, 96 (06) : 1798 - 1802
  • [18] Implications of Noise on Deep Learning Models for 12-Lead ECG Construction
    Jain, Utkars
    Leasure, Michael
    Butchy, Adam
    Covalesky, Veronica A.
    Mintz, Gary S.
    CIRCULATION, 2023, 148
  • [19] Validation of Deep Learning System for Comprehensive 12-Lead ECG Interpretation
    Herman, Robert
    Demolder, Anthony
    Vavrik, Boris
    Martonak, Michal
    Boza, Vladimir
    Fabbricatore, Davide
    Perl, Leor
    Bartunek, Jozef
    Hatala, Robert
    CIRCULATION, 2023, 148
  • [20] Detection of myocardial infarction in 12 lead ECG using support vector machine
    Dohare, Ashok Kumar
    Kumar, Vinod
    Kumar, Ritesh
    APPLIED SOFT COMPUTING, 2018, 64 : 138 - 147