Using a Boron-Doped Diamond Electrode in Anionic Surfactant Media as an Improved Electrochemical Sensor for the Anticancer Drug Ibrutinib

被引:2
|
作者
Mete, Cihat [1 ]
Pinar, Pinar Talay [1 ]
机构
[1] Van Yuzuncu Yil Univ, Inst Van Yuzuncu Yil Univ, Fac Pharm, Dept Analyt Chem, Van, Turkiye
来源
CHEMISTRYSELECT | 2023年 / 8卷 / 06期
关键词
Anticancer drug; Ibrutinib; Real samples; Surfactant; Voltammetry; MANTLE CELL LYMPHOMA; VALIDATION;
D O I
10.1002/slct.202204492
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The electrochemical properties of ibrutinib (IBR), a new generation smart anti-cancer drug, one of the Bruton's tyrosine kinase (BTK) inhibitors were investigated by a voltammetric method in the anionic surfactant (sodium dodecyl sulfate, SDS) medium with the boron-doped diamond electrode (BDDE). IBR showed an oxidation step at about +1.56 V (vs Ag/AgCl (3.0 mol L-1 KCl) by cyclic voltammetry (CV) technique in 0.1 mol L-1 H2SO4 solution. IBR was found to be irreversible and diffusion-controlled on the surface of the BDDE with studies of scan rate. The possible electrochemical oxidation reaction of IBR with the electroactive ring (pyrazole-pyrimidine ring) in the structure of IBR is discussed. Square wave voltammetry (SWV) was preferred as the study method due to reproducibility for the determination of IBR in pharmaceutical and urine samples. At optimal values of SWV parameters, IBR showed good linearity in the concentration range of 0.01-2.00 mu g mL(-1) (5.7x10(-8)-2.3x10(-6) mol L-1) in 0.1 mol L-1 H2SO4 with 6x10(-4) M SDS. The detection (LOD) and quantification (LOQ) limits for IBR were set at 0.003 mu g mL(-1) (6.9x10(-9) mol L-1) and 0.01 mu g mL(-1) (2.27x10(-8) mol L-1), respectively. The relative standard deviation of the intra-day and inter-day repeatability of the proposed method was found 2.15 and 3.76, respectively. The necessary validation parameters have also been studied, and the recovery results obtained from both pharmaceutical dosage form and human urine samples show that the developed method is accurate and precise.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Sensitive determination of anticancer drug imatinib in spiked human urine samples by differential pulse voltammetry on anodically pretreated boron-doped diamond electrode
    Brycht, Mariola
    Kaczmarska, Kinga
    Uslu, Bengi
    Ozkan, Sibel A.
    Skrzypek, Slawomira
    DIAMOND AND RELATED MATERIALS, 2016, 68 : 13 - 22
  • [33] Electrochemical evaluation and determination of antiretroviral drug fosamprenavir using boron-doped diamond and glassy carbon electrodes
    Mehmet Gumustas
    Sibel A. Ozkan
    Analytical and Bioanalytical Chemistry, 2010, 397 : 189 - 203
  • [34] Voltammetric determination of leucovorin in pharmaceutical preparations using a boron-doped diamond electrode
    Renáta Šelešovská
    Barbora Kränková
    Michaela Štěpánková
    Pavlína Martinková
    Lenka Janíková
    Jaromíra Chýlková
    Tomáš Navrátil
    Monatshefte für Chemie - Chemical Monthly, 2018, 149 : 1701 - 1708
  • [35] The first electrochemical evaluation and voltammetric detection of the insecticide emamectin benzoate using an unmodified boron-doped diamond electrode
    McCormick, Wesley J.
    Robertson, Peter K. J.
    Skillen, Nathan
    McCrudden, Denis
    RESULTS IN CHEMISTRY, 2023, 5
  • [36] Boron-Doped Diamond Electrodes: Recent Developments and Advances in View of Electrochemical Drug Sensors
    Yence, Merve
    Cetinkaya, Ahmet
    Ozcelikay, Goksu
    Kaya, S. Irem
    Ozkan, Sibel A.
    CRITICAL REVIEWS IN ANALYTICAL CHEMISTRY, 2022, 52 (05) : 1122 - 1138
  • [37] Voltammetric determination of leucovorin in pharmaceutical preparations using a boron-doped diamond electrode
    Selesovska, Renata
    Krankova, Barbora
    Stepankova, Michaela
    Martinkova, Pavlina
    Janikova, Lenka
    Chylkova, Jaromira
    Navratil, Tomas
    MONATSHEFTE FUR CHEMIE, 2018, 149 (09): : 1701 - 1708
  • [38] Electrochemical study of 4-chloro-3-methylphenol on anodically pretreated boron-doped diamond electrode in the absence and presence of a cationic surfactant
    Brycht, Mariola
    Lochynski, Pawel
    Barek, Jiri
    Skrzypek, Slawomira
    Kuczewski, Krzysztof
    Schwarzova-Peckova, Karolina
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2016, 771 : 1 - 9
  • [39] Electrooxidation of trifloxystrobin at the boron-doped diamond electrode: electrochemical mechanism, quantitative determination and degradation studies
    Almeida, Joseany M. S.
    Toloza, Carlos A. T.
    Dornellas, Rafael M.
    da Silva, Andrea R.
    Aucelio, Ricardo Q.
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2016, 96 (10) : 959 - 977
  • [40] Electrochemical detection of triamterene in human urine using boron-doped diamond electrodes
    Ishii, Kanako
    Ogata, Genki
    Einaga, Yasuaki
    BIOSENSORS & BIOELECTRONICS, 2022, 217