The electrochemical properties of ibrutinib (IBR), a new generation smart anti-cancer drug, one of the Bruton's tyrosine kinase (BTK) inhibitors were investigated by a voltammetric method in the anionic surfactant (sodium dodecyl sulfate, SDS) medium with the boron-doped diamond electrode (BDDE). IBR showed an oxidation step at about +1.56 V (vs Ag/AgCl (3.0 mol L-1 KCl) by cyclic voltammetry (CV) technique in 0.1 mol L-1 H2SO4 solution. IBR was found to be irreversible and diffusion-controlled on the surface of the BDDE with studies of scan rate. The possible electrochemical oxidation reaction of IBR with the electroactive ring (pyrazole-pyrimidine ring) in the structure of IBR is discussed. Square wave voltammetry (SWV) was preferred as the study method due to reproducibility for the determination of IBR in pharmaceutical and urine samples. At optimal values of SWV parameters, IBR showed good linearity in the concentration range of 0.01-2.00 mu g mL(-1) (5.7x10(-8)-2.3x10(-6) mol L-1) in 0.1 mol L-1 H2SO4 with 6x10(-4) M SDS. The detection (LOD) and quantification (LOQ) limits for IBR were set at 0.003 mu g mL(-1) (6.9x10(-9) mol L-1) and 0.01 mu g mL(-1) (2.27x10(-8) mol L-1), respectively. The relative standard deviation of the intra-day and inter-day repeatability of the proposed method was found 2.15 and 3.76, respectively. The necessary validation parameters have also been studied, and the recovery results obtained from both pharmaceutical dosage form and human urine samples show that the developed method is accurate and precise.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Electrochemical Determination of Flavonoid Fisetin in Commercial Dietary Supplements Using a Boron-Doped Diamond Electrode
    Allahverdiyeva, Shabnam
    Keskin, Ertugrul
    Yoruk, Ibrahim
    Yardim, Yavuz
    CHEMISTRYSELECT, 2023, 8 (14):
  • [22] Electrochemical measurement of lamotrigine using boron-doped diamond electrodes
    Hanawa, Ai
    Asai, Kai
    Ogata, Genki
    Hibino, Hiroshi
    Einaga, Yasuaki
    ELECTROCHIMICA ACTA, 2018, 271 : 35 - 40
  • [23] Gemcitabine Direct Electrochemical Detection from Pharmaceutical Formulations Using a Boron-Doped Diamond Electrode
    Rus, Iulia
    Pusta, Alexandra
    Tertis, Mihaela
    Barbalata, Cristina
    Tomuta, Ioan
    Sandulescu, Robert
    Cristea, Cecilia
    PHARMACEUTICALS, 2021, 14 (09)
  • [24] Non-enzymatic electrochemical detection of glycerol on boron-doped diamond electrode
    Pop, Aniela
    Manea, Florica
    Radovan, Ciprian
    Dascalu, Dana
    Vaszilcsin, Nicolae
    Schoonman, Joop
    ANALYST, 2012, 137 (03) : 641 - 647
  • [25] Sensing of the COVID-19 antiviral molnupiravir in the presence of an anionic surfactant on the surface of a boron-doped diamond electrode in pharmaceutical formulation
    Bedir, Yunus
    Yardim, Yavuz
    MONATSHEFTE FUR CHEMIE, 2025, 156 (02): : 145 - 154
  • [26] Boron-doped diamond electrodes in organic media: Electrochemical activation and selectivity effects
    Kulandainathan, M. Anbu
    Hall, Clive
    Wolverson, Daniel
    Foord, John S.
    MacDonald, Stuart M.
    Marken, Frank
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2007, 606 (02) : 150 - 158
  • [27] Sensitive determination and electrochemical evaluation of anticancer drug tofacitinib in pharmaceutical and biological samples using glassy carbon and boron-doped diamond electrodes
    Budak, Fatma
    Cetinkaya, Ahmet
    Kaya, S. Irem
    Atici, Esen Bellur
    Ozkan, Sibel A.
    DIAMOND AND RELATED MATERIALS, 2023, 133
  • [28] Electrochemical oxidation of paracetamol on boron-doped diamond electrode: analytical performance and paracetamol degradation
    Kouadio, Kouakou E.
    Kambire, Ollo
    Koffi, Konan S.
    Ouattara, Lassine
    JOURNAL OF ELECTROCHEMICAL SCIENCE AND ENGINEERING, 2021, 11 (02): : 71 - 86
  • [29] Electrochemical Detection of Melatonin at Nano-Sized Highly Boron-Doped Diamond Electrode
    Satianram, Witchayatip
    Sunon, Pachanuporn
    Ngokpho, Busarakham
    Nijpanich, Supinya
    Chanlek, Narong
    Khotavivattana, Tanatorn
    Batchelor-McAuley, Christopher
    Ngamchuea, Kamonwad
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2024, 171 (08)
  • [30] Voltammetric analysis of mephenoxalone drug in pharmaceutical and biological samples using novel screen-printed sensor with boron-doped diamond electrode
    Matvieiev, Oleksandr
    Selesovska, Renata
    Sokolova, Romana
    Jerga, Radek
    Skopalova, Jana
    Bartak, Petr
    Chylkova, Jaromira
    Vojs, Marian
    SENSORS AND ACTUATORS B-CHEMICAL, 2023, 397