Using a Boron-Doped Diamond Electrode in Anionic Surfactant Media as an Improved Electrochemical Sensor for the Anticancer Drug Ibrutinib

被引:2
|
作者
Mete, Cihat [1 ]
Pinar, Pinar Talay [1 ]
机构
[1] Van Yuzuncu Yil Univ, Inst Van Yuzuncu Yil Univ, Fac Pharm, Dept Analyt Chem, Van, Turkiye
来源
CHEMISTRYSELECT | 2023年 / 8卷 / 06期
关键词
Anticancer drug; Ibrutinib; Real samples; Surfactant; Voltammetry; MANTLE CELL LYMPHOMA; VALIDATION;
D O I
10.1002/slct.202204492
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The electrochemical properties of ibrutinib (IBR), a new generation smart anti-cancer drug, one of the Bruton's tyrosine kinase (BTK) inhibitors were investigated by a voltammetric method in the anionic surfactant (sodium dodecyl sulfate, SDS) medium with the boron-doped diamond electrode (BDDE). IBR showed an oxidation step at about +1.56 V (vs Ag/AgCl (3.0 mol L-1 KCl) by cyclic voltammetry (CV) technique in 0.1 mol L-1 H2SO4 solution. IBR was found to be irreversible and diffusion-controlled on the surface of the BDDE with studies of scan rate. The possible electrochemical oxidation reaction of IBR with the electroactive ring (pyrazole-pyrimidine ring) in the structure of IBR is discussed. Square wave voltammetry (SWV) was preferred as the study method due to reproducibility for the determination of IBR in pharmaceutical and urine samples. At optimal values of SWV parameters, IBR showed good linearity in the concentration range of 0.01-2.00 mu g mL(-1) (5.7x10(-8)-2.3x10(-6) mol L-1) in 0.1 mol L-1 H2SO4 with 6x10(-4) M SDS. The detection (LOD) and quantification (LOQ) limits for IBR were set at 0.003 mu g mL(-1) (6.9x10(-9) mol L-1) and 0.01 mu g mL(-1) (2.27x10(-8) mol L-1), respectively. The relative standard deviation of the intra-day and inter-day repeatability of the proposed method was found 2.15 and 3.76, respectively. The necessary validation parameters have also been studied, and the recovery results obtained from both pharmaceutical dosage form and human urine samples show that the developed method is accurate and precise.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] VOLTAMMETRIC DETERMINATION OF ANTI-MALARIAL DRUG AMODIAQUINE AT A BORON-DOPED DIAMOND ELECTRODE SURFACE IN AN ANIONIC SURFACTANT MEDIA
    Kamal, Sara Kurdo
    Yardim, Yavuz
    MACEDONIAN JOURNAL OF CHEMISTRY AND CHEMICAL ENGINEERING, 2022, 41 (02) : 1 - 12
  • [2] Electrochemical performance of boron-doped diamond electrode in surfactant-containing media for ambroxol determination
    Levent, Abdulkadir
    Yardim, Yavuz
    Senturk, Zuhre
    SENSORS AND ACTUATORS B-CHEMICAL, 2014, 203 : 517 - 526
  • [3] Electrochemical Determination of Fluoroquinolone Antibiotic Norfloxacin in the Presence of Anionic Surfactant Using the Anodically Pretreated Boron-Doped Diamond Electrode
    Karahan, Fatih
    Basi, Zehra
    Keskin, Ertugrul
    Pinar, Pinar Talay
    Yardim, Yavuz
    Senturk, Zuhre
    CHEMISTRYSELECT, 2020, 5 (42): : 12862 - 12868
  • [4] Investigation of the electrochemical properties of vinblastine on boron-doped diamond electrode treated with anodic pre-treatment in anionic surfactant medium
    Onal, Gunay
    DIAMOND AND RELATED MATERIALS, 2023, 133
  • [5] ELECTROCHEMICAL DETERMINATION OF DICLOFENAC USING BORON-DOPED DIAMOND ELECTRODE
    Ihos, M.
    Remes, A.
    Manea, F.
    JOURNAL OF ENVIRONMENTAL PROTECTION AND ECOLOGY, 2012, 13 (04): : 2096 - 2103
  • [6] Application of boron-doped diamond electrode for rapid and sensitive voltammetric detection of vildagliptin in anionic surfactant medium
    Altunkaynak, Yalcin
    Onal, Gunay
    Levent, Abdulkadir
    MONATSHEFTE FUR CHEMIE, 2023, 154 (02): : 181 - 190
  • [7] Application of boron-doped diamond electrode for rapid and sensitive voltammetric detection of vildagliptin in anionic surfactant medium
    Yalçın Altunkaynak
    Günay Önal
    Abdulkadir Levent
    Monatshefte für Chemie - Chemical Monthly, 2023, 154 : 181 - 190
  • [8] Electrochemical evaluation and voltammetric determination of laxative drug bisacodyl on boron-doped diamond electrode
    Falone, Max Fabricio
    Rossi Salamanca-Neto, Carlos Alberto
    Moraes, Jaqueline Tobias
    Sartori, Elen Romao
    MEASUREMENT, 2019, 137 : 464 - 469
  • [9] Electrochemical determination of cephalosporins using a bare boron-doped diamond electrode
    Feier, Bogdan
    Gui, Ana
    Cristea, Cecilia
    Sandulescu, Robert
    ANALYTICA CHIMICA ACTA, 2017, 976 : 25 - 34
  • [10] Electrochemical determination of cefotaxime, a cephalosporin group drug, at a boron-doped diamond electrode
    Tunc, Bilal
    Amudi, Karina
    Pinar, PInar Talay
    JOURNAL OF RESEARCH IN PHARMACY, 2022, 26 (05): : 1484 - 1492