In vitro and in vivo degradation correlations for polyurethane foams with tunable degradation rates

被引:11
作者
Vakil, Anand Utpal [1 ]
Petryk, Natalie Marie [1 ]
Du, Changling [1 ]
Howes, Bryanna [2 ]
Stinfort, Darnelle [3 ]
Serinelli, Serenella [4 ]
Gitto, Lorenzo [4 ]
Ramezani, Maryam [1 ]
Beaman, Henry T. [1 ]
Monroe, Mary Beth Browning [1 ,5 ]
机构
[1] Syracuse Univ, Inst Mat & Living Syst, Dept Biomed & Chem Engn & BioInspired Syracuse, Syracuse, NY USA
[2] Moyne Coll, Dept Chem, Syracuse, NY USA
[3] Syracuse Univ, Biotechnol Program, Syracuse, NY USA
[4] SUNY Upstate Med Univ, Syracuse, NY USA
[5] Syracuse Univ, Inst Mat & Living Syst, Dept Biomed & Chem Engn, BioInspired Syracuse, 318 Bowne Hall, Syracuse, NY 13244 USA
关键词
degradation; foams; polyurethane; shape memory polymers; SHAPE-MEMORY POLYMER; POLY(ETHER URETHANE) BIODEGRADATION; POLY(CARBONATE URETHANE); TERTIARY-AMINES; TISSUE; SCAFFOLD; BIOCOMPATIBILITY; IMPLANTATION; CYTOTOXICITY; BIOSTABILITY;
D O I
10.1002/jbm.a.37504
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Polyurethane foams present a tunable biomaterial platform with potential for use in a range of regenerative medicine applications. Achieving a balance between scaffold degradation rates and tissue ingrowth is vital for successful wound healing, and significant in vivo testing is required to understand these processes. Vigorous in vitro testing can minimize the number of animals that are required to gather reliable data; however, it is difficult to accurately select in vitro degradation conditions that can effectively mimic in vivo results. To that end, we performed a comprehensive in vitro assessment of the degradation of porous shape memory polyurethane foams with tunable degradation rates using varying concentrations of hydrogen peroxide to identify the medium that closely mimics measured in vivo degradation rates. Material degradation was studied over 12 weeks in vitro in 1%, 2%, or 3% hydrogen peroxide and in vivo in subcutaneous pockets in Sprague Dawley rats. We found that the in vitro degradation conditions that best predicted in vivo degradation rates varied based on the number of mechanisms by which the polymer degraded and the polymer hydrophilicity. Namely, more hydrophilic materials that degrade by both hydrolysis and oxidation require lower concentrations of hydrogen peroxide (1%) to mimic in vivo rates, while more hydrophobic scaffolds that degrade by oxidation alone require higher concentrations of hydrogen peroxide (3%) to model in vivo degradation. This information can be used to rationally select in vitro degradation conditions that accurately identify in vivo degradation rates prior to characterization in an animal model.
引用
收藏
页码:580 / 595
页数:16
相关论文
共 62 条
[1]  
[Anonymous], 2009, ISO 10993-5, DOI DOI 10.2345/9781570203558.CH1
[2]  
[Anonymous], 2022, 10993132010 ISO
[3]   Biocompatibility evaluation of crosslinked chitosan hydrogels after subcutaneous and intraperitoneal implantation in the rat [J].
Azab, Abdel Kareem ;
Doviner, Victoria ;
Orkin, Boris ;
Kleinstem, Jackie ;
Srebnik, Morris ;
Nissan, Aviram ;
Rubinstein, Abraham .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2007, 83A (02) :414-422
[4]   Mild and efficient flavin-catalyzed H2O2 oxidation of tertiary amines to amine N-oxides [J].
Bergstad, K ;
Bäckvall, JE .
JOURNAL OF ORGANIC CHEMISTRY, 1998, 63 (19) :6650-6655
[5]   DEGRADATIVE BEHAVIOR OF POLYMERIC MATRICES IN (SUB)DERMAL AND MUSCLE-TISSUE OF THE RAT - A QUANTITATIVE STUDY [J].
BEUMER, GJ ;
VANBLITTERSWIJK, CA ;
PONEC, M .
BIOMATERIALS, 1994, 15 (07) :551-559
[6]   In vitro and in vivo evaluation of a shape memory polymer foam-over-wire embolization device delivered in saccular aneurysm models [J].
Boyle, Anthony J. ;
Landsman, Todd L. ;
Wierzbicki, Mark A. ;
Nash, Landon D. ;
Hwang, Wonjun ;
Miller, Matthew W. ;
Tuzun, Egemen ;
Hasan, Sayyeda M. ;
Maitland, Duncan J. .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2016, 104 (07) :1407-1415
[7]   Determination of the in vivo degradation mechanism of PEGDA hydrogels [J].
Browning, M. B. ;
Cereceres, S. N. ;
Luong, P. T. ;
Cosgriff-Hernandez, E. M. .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2014, 102 (12) :4244-4251
[8]   Scaffolding in tissue engineering: general approaches and tissue-specific considerations [J].
Chan, B. P. ;
Leong, K. W. .
EUROPEAN SPINE JOURNAL, 2008, 17 (Suppl 4) :S467-S479
[9]   Oxidative mechanisms of poly(carbonate urethane) and poly(ether urethane) biodegradation:: In vivo and in vitro correlations [J].
Christenson, EM ;
Anderson, JM ;
Hiltner, A .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2004, 70A (02) :245-255
[10]   Poly(carbonate urethane) and poly(ether urethane) biodegradation:: In vivo studies [J].
Christenson, EM ;
Dadsetan, M ;
Wiggins, M ;
Anderson, JM ;
Hiltner, A .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2004, 69A (03) :407-416