Transdermal amperometric biosensors for continuous glucose monitoring in diabetes

被引:13
作者
Liu, Yiqun [1 ]
Yang, Li [2 ]
Cui, Yue [1 ]
机构
[1] Peking Univ, Hosp Interdisciplinary 1, Sch Mat Sci & Engn, Res Ctr, Beijing 100871, Peoples R China
[2] Peking Univ, Peking Univ Hosp 1, Peking Univ Inst Nephrol, Renal Div,Minist Hlth China,Key Lab Renal Dis,Key, Beijing 100034, Peoples R China
基金
中国国家自然科学基金; 国家重点研发计划;
关键词
Diabetes; Glucose; Amperometric biosensors; Interstitial fluid; Continuous monitoring; PRUSSIAN-BLUE; INTERSTITIAL GLUCOSE; ENZYME ELECTRODE; CARBON NANOTUBES; IN-VITRO; IMPLANTABLE BIOSENSOR; ARTIFICIAL PANCREAS; MICRONEEDLE ARRAY; CHEMICAL SENSORS; REDOX MEDIATORS;
D O I
10.1016/j.talanta.2022.124033
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Diabetes is a highly prevalent and chronic metabolic disease, and the continuous monitoring of diabetes is of great importance for diabetes management. Interstitial fluid glucose has an excellent correlation with blood glucose, and therefore transdermal glucose biosensors can provide accurate monitoring of diabetes. The ongoing challenges are the synergetic integration of biosensing principles, device configuration, signal transduction, novel materials, and fabrication methods. In recent years, there have been several attempts for developing new-transdermal glucose biosensors. To successfully construct a transdermal glucose biosensor, there are several interesting questions: What is the sensing principle for diabetes monitoring? What device configuration should be used? What kinds of materials should be chosen and how to integrate them into one device? What are the application and commercial status? This review would attempt to address the above questions, and explore the fundamental aspects and the practical applications of a variety of transdermal glucose biosensors. It is antici-pated that this review could open up exciting opportunities for the development of next-generation transdermal devices, as well as providing monitoring methods for diabetes patients.
引用
收藏
页数:20
相关论文
共 50 条
[41]   Benefits and limitations of continuous glucose monitoring in type 1 diabetes [J].
Stone, Jenine Y. ;
Bailey, Timothy S. .
EXPERT REVIEW OF ENDOCRINOLOGY & METABOLISM, 2020, 15 (01) :41-49
[43]   Non-invasive monitoring of diabetes and hypoxia based on continuous sweat analysis by flow-through biosensors [J].
Karpova, Elena, V ;
Shcherbacheva, Elizaveta, V ;
Karyakina, Elena E. ;
Karyakin, Arkady A. .
PROCEEDINGS OF THE 15TH INTERNATIONAL STUDENTS CONFERENCE MODERN ANALYTICAL CHEMISTRY, 2019, :190-196
[44]   EFFECT OF INTERFERENCE ON AMPEROMETRIC GLUCOSE BIOSENSORS WITH CELLULOSE-ACETATE MEMBRANES [J].
VAIDYA, R ;
WILKINS, E .
ELECTROANALYSIS, 1994, 6 (08) :677-682
[45]   DEVELOPMENT OF MEDIATED AMPEROMETRIC BIOSENSORS FOR HYPOXANTHINE, GLUCOSE AND LACTATE - A NEW FORMAT [J].
NGUYEN, AL ;
LUONG, JHT .
BIOSENSORS & BIOELECTRONICS, 1993, 8 (9-10) :421-431
[46]   Generalized Compact Modeling of Nanoparticle-Based Amperometric Glucose Biosensors [J].
Jin, Xin ;
Fisher, Timothy S. ;
Alam, Muhammad Ashraful .
IEEE TRANSACTIONS ON ELECTRON DEVICES, 2016, 63 (12) :4924-4932
[47]   Reengineered glucose oxidase for amperometric glucose determination in diabetes analytics [J].
Gutierrez, Erik Arango ;
Mundhada, Hemanshu ;
Meier, Thomas ;
Duefel, Hartmut ;
Bocola, Marco ;
Schwaneberg, Ulrich .
BIOSENSORS & BIOELECTRONICS, 2013, 50 :84-90
[48]   A method for continuous glucose monitoring in interstitial fluid based on microdialysis [J].
Li, D. (dchli@tju.edu.cn), 1600, Tianjin University (46) :482-486
[49]   An Interstitial Fluid Transdermal Extraction Chip with Vacuum Generator and Volume Sensor for Continuous Glucose Monitoring [J].
Yu, Haixia ;
Li, Dachao ;
Ji, Yongjie ;
Zhang, Xiaoli ;
Xu, Kexin .
MICRO-NANO TECHNOLOGY XIV, PTS 1-4, 2013, 562-565 :571-575
[50]   A combined diabetes and continuous glucose monitoring education program for adults with type 2 diabetes [J].
Lind, Nanna ;
Christensen, Merete Bechmann ;
Norgaard, Kirsten .
PEC INNOVATION, 2024, 5