Accuracy of Traditional and Modern Formulas for Intraocular Lens Power Calculation After Radial Keratotomy Using Standard Keratometry

被引:2
|
作者
Helaly, Hany Ahmed [1 ,2 ]
Elhady, Amr Mohamed [1 ]
Elnaggar, Osama Ramadan [1 ]
机构
[1] Alexandria Univ, Fac Med, Ophthalmol Dept, Alexandria, Egypt
[2] Alexandria Univ, Fac Med, Ophthalmol Dept, 30 Roshdy St, Alexandria, Egypt
来源
CLINICAL OPHTHALMOLOGY | 2023年 / 17卷
关键词
radial keratotomy; IOL calculation; PEARL-DGS; Barrett True-K; DK Holladay 1; DK SRK/T; CORNEAL TOPOGRAPHY; CATARACT-SURGERY;
D O I
10.2147/OPTH.S417336
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To compare the accuracy of multiple traditional and modern intraocular lens (IOL) power calculation formulas in post-radial keratotomy (RK) patients undergoing cataract surgery.Methods: This retrospective case series included 50 eyes with prior RK who underwent routine phacoemulsification surgery with single-piece acrylic IOL implantation (A constant = 118.8). Outcomes of multiple formulas were calculated. Included formulas were SRK/T, Holladay 1, Holladay 2, Haigis, Barrett True-K, Haigis and Barrett True-K (target refraction of 0.50 D), Barrett Universal II, Kane, PEARL-DGS, Shammas no history, DK SRK/T, DK SRK/T (target refraction of 0.50 D), Double K (DK) Holladay 1, and DK Holladay 1 (target refraction of 0.50 D). Averages of multiple combinations of best-performing single formulas were calculated. Primary outcome is mean absolute error (MAE).Results: Haigis (with -0.50 D target refraction) and DK SRK/T showed the lowest mean and median absolute errors (MedAE) followed by Haigis, Barrett True-K, and Barrett True-K (with -0.50 D target refraction). Combinations of 3, 4, or 5 of best performing single formulas yielded good results with >60% of cases within +0.50 D of intended refraction and MAE around 0.50 D. The best performing formulas with flatter K readings were PEARL-DGS and Haigis (with additional -0.50 D target refraction) with MAE of 0.72 + 0.71 D and 0.70 + 0.70 D, respectively, followed by Barrett True-K (with intended -0.50 D target refraction) with MAE of 0.75 + 0.63 D.Conclusion: Using an average of three or more Haigis (with -0.50 D target refraction), the Barrett True-K, DK Holladay 1, and DK SRK/T formulas showed better outcomes than using a single formula for IOLMaster 700 standard K readings. The PEARL-DGS formula showed better accuracy in eyes with flatter K readings (<38 D).
引用
收藏
页码:2589 / 2597
页数:9
相关论文
共 50 条
  • [41] Evaluation of total keratometry and its accuracy for intraocular lens power calculation in eyes after corneal refractive surgery
    Wang, Li
    Spektor, Tatyana
    de Souza, Rodrigo G.
    Koch, Douglas D.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2019, 45 (10): : 1416 - 1421
  • [42] Comparing the accuracy of intraocular lens power calculation formulas using artificial intelligence and traditional formulas in highly myopic patients: a meta-analysis
    Hao, Yuxu
    Fu, Jin
    Huang, Jin
    Chen, Ding
    INTERNATIONAL OPHTHALMOLOGY, 2024, 44 (01)
  • [43] Intraocular lens power calculation formula accuracy: Comparison of 12 formulas for a trifocal hydrophilic intraocular lens
    Rocha-de-Lossada, Carlos
    Colmenero-Reina, Elvira
    Flikier, David
    Castro-Alonso, Francisco-Javier
    Rodriguez-Raton, Alvaro
    Garcia-Madrona, Jose-Luis
    Peraza-Nieves, Jorge
    Sanchez-Gonzalez, Jose-Maria
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2021, 31 (06) : 2981 - 2988
  • [44] Comparison of the accuracy of intraocular lens power calculation formulas for eyes after corneal refractive surgery
    Wang, Xiao-Zhen
    Cui, Rui
    Song, Xu-Dong
    Yun, Bo
    Qian, Jin
    Ding, Ning
    ANNALS OF TRANSLATIONAL MEDICINE, 2020, 8 (14)
  • [45] Accuracy of Intraocular Lens Power Calculation Based on Total Keratometry in Patients With Flat and Steep Corneas
    Qin, Y. I. N. G. Y. A. N.
    Liu, L. I. A. N. G. P. I. N. G.
    Mao, Y. A. N.
    Ding, Y. U. J. I. E.
    Ye, S. H. A. O. B., I
    Sun, A. O.
    Wu, M. I. N. G. X. I. N. G.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2023, 247 : 103 - 110
  • [46] Accuracy of intraocular lens power calculation formulas using a swept-source optical biometer
    Kim, Se Young
    Lee, Seung Hyun
    Kim, Na Rae
    Chin, Hee Seung
    Jung, Ji Won
    PLOS ONE, 2020, 15 (01):
  • [47] Standard vs total keratometry for intraocular lens power calculation in cataract surgery combined with DMEK
    Khan, Asher
    Rangu, Neal
    Murphy, David A.
    Cooke, David L.
    Siatkowski, Rhea L.
    Mittal, Aman
    Wendelstein, Jascha A.
    Riaz, Kamran M.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2023, 49 (03): : 239 - 245
  • [48] Comparison of the accuracy of nine intraocular lens power calculation formulas using partial coherence interferometry
    Maroun, A.
    El Shami, M.
    Hoyek, S.
    Antoun, J.
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 2023, 46 (04): : 341 - 347
  • [49] Intraocular lens power calculations in eyes with previous radial keratotomy
    Wang, Li
    Waisbren, Emily
    Weikert, Mitchell P.
    Koch, Douglas D.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [50] Intraocular lens power calculation using standard formulas and ray tracing after DMEK in patients with Fuchs endothelial dystrophy
    Alnawaiseh, Maged
    Zumhagen, Lars
    Rosentreter, Andre
    Eter, Nicole
    BMC OPHTHALMOLOGY, 2017, 17