Accuracy of Traditional and Modern Formulas for Intraocular Lens Power Calculation After Radial Keratotomy Using Standard Keratometry

被引:2
|
作者
Helaly, Hany Ahmed [1 ,2 ]
Elhady, Amr Mohamed [1 ]
Elnaggar, Osama Ramadan [1 ]
机构
[1] Alexandria Univ, Fac Med, Ophthalmol Dept, Alexandria, Egypt
[2] Alexandria Univ, Fac Med, Ophthalmol Dept, 30 Roshdy St, Alexandria, Egypt
来源
CLINICAL OPHTHALMOLOGY | 2023年 / 17卷
关键词
radial keratotomy; IOL calculation; PEARL-DGS; Barrett True-K; DK Holladay 1; DK SRK/T; CORNEAL TOPOGRAPHY; CATARACT-SURGERY;
D O I
10.2147/OPTH.S417336
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To compare the accuracy of multiple traditional and modern intraocular lens (IOL) power calculation formulas in post-radial keratotomy (RK) patients undergoing cataract surgery.Methods: This retrospective case series included 50 eyes with prior RK who underwent routine phacoemulsification surgery with single-piece acrylic IOL implantation (A constant = 118.8). Outcomes of multiple formulas were calculated. Included formulas were SRK/T, Holladay 1, Holladay 2, Haigis, Barrett True-K, Haigis and Barrett True-K (target refraction of 0.50 D), Barrett Universal II, Kane, PEARL-DGS, Shammas no history, DK SRK/T, DK SRK/T (target refraction of 0.50 D), Double K (DK) Holladay 1, and DK Holladay 1 (target refraction of 0.50 D). Averages of multiple combinations of best-performing single formulas were calculated. Primary outcome is mean absolute error (MAE).Results: Haigis (with -0.50 D target refraction) and DK SRK/T showed the lowest mean and median absolute errors (MedAE) followed by Haigis, Barrett True-K, and Barrett True-K (with -0.50 D target refraction). Combinations of 3, 4, or 5 of best performing single formulas yielded good results with >60% of cases within +0.50 D of intended refraction and MAE around 0.50 D. The best performing formulas with flatter K readings were PEARL-DGS and Haigis (with additional -0.50 D target refraction) with MAE of 0.72 + 0.71 D and 0.70 + 0.70 D, respectively, followed by Barrett True-K (with intended -0.50 D target refraction) with MAE of 0.75 + 0.63 D.Conclusion: Using an average of three or more Haigis (with -0.50 D target refraction), the Barrett True-K, DK Holladay 1, and DK SRK/T formulas showed better outcomes than using a single formula for IOLMaster 700 standard K readings. The PEARL-DGS formula showed better accuracy in eyes with flatter K readings (<38 D).
引用
收藏
页码:2589 / 2597
页数:9
相关论文
共 50 条
  • [21] Accuracy of eight intraocular lens power calculation formulas for segmented multifocal intraocular lens
    Zhao, Jing
    Liu, Liang-Ping
    Cheng, Huan-Huan
    Li, Jian-Bing
    Han, Xiao-Tong
    Liu, Yu
    Wu, Ming-Xing
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2020, 13 (09) : 1378 - 1384
  • [22] Accuracy of eight intraocular lens power calculation formulas for segmented multifocal intraocular lens
    Jing Zhao
    Liang-Ping Liu
    Huan-Huan Cheng
    Jian-Bing Li
    Xiao-Tong Han
    Yu Liu
    Ming-Xing Wu
    International Journal of Ophthalmology, 2020, (09) : 1378 - 1384
  • [23] Accuracy of Intraocular Lens Calculation Formulas
    Melles, Ronald B.
    Holladay, Jack T.
    Chang, William J.
    OPHTHALMOLOGY, 2018, 125 (02) : 169 - 178
  • [24] Comparison of 9 modern intraocular lens power calculation formulas for a quadrifocal intraocular lens
    Shajari, Mehdi
    Kolb, Carolin M.
    Petermann, Kerstin
    Boehm, Myriam
    Herzog, Michael
    de'Lorenzo, Nina
    Schoenbrunn, Sabrina
    Kohnen, Thomas
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2018, 44 (08): : 942 - 948
  • [25] Intraocular lens power calculation in high myopic eyes with previous radial keratotomy
    Han, Eui Seok
    Lee, Jin Hak
    JOURNAL OF REFRACTIVE SURGERY, 2006, 22 (07) : 713 - 716
  • [26] Evaluation of the Accuracy of Intraocular Lens Power Calculation Formulas in Phacovitrectomy
    Tanaka, Yuichiro
    Kamiya, Kazutaka
    Igarahi, Akihito
    Shoji, Nobuyuki
    Tsuchiya, Hiroshi
    Takahashi, Shinya
    Ishikawa, Eri
    Kozawa, Tadahiko
    OPHTHALMOLOGY AND THERAPY, 2024, 13 (08) : 2197 - 2208
  • [27] Comparison of the accuracy of 11 intraocular lens power calculation formulas
    Carmona-Gonzalez, David
    Castillo-Gomez, Alfredo
    Palomino-Bautista, Carlos
    Romero-Dominguez, Marta
    Gutierrez-Moreno, Maria Angeles
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2021, 31 (05) : 2370 - 2376
  • [28] Analysis of intraocular lens power calculation in post-radial keratotomy eyes
    Chen, L
    Mannis, MJ
    Salz, JJ
    Garcia-Ferrer, FJ
    Ge, J
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2003, 29 (01): : 65 - 70
  • [29] Accuracy of Ten Intraocular Lens Formulas in Spherical Equivalent of Toric Intraocular Lens Power Calculation
    Jingyi Shi
    Zehui Zhu
    Bin Hu
    Shuyi Qian
    Yalan Wang
    Pingjun Chang
    Yun-e Zhao
    Ophthalmology and Therapy, 2024, 13 : 1321 - 1342
  • [30] Accuracy of New Intraocular Lens Power Calculation Formulas: A Lens Thickness Study
    Taroni, Leonardo
    Hoffer, Kenneth J.
    Lupardi, Enrico
    Barboni, Piero
    Savini, Giacomo
    JOURNAL OF REFRACTIVE SURGERY, 2021, 37 (03) : 202 - 206