摘要
Purpose: To compare the accuracy of multiple traditional and modern intraocular lens (IOL) power calculation formulas in post-radial keratotomy (RK) patients undergoing cataract surgery.Methods: This retrospective case series included 50 eyes with prior RK who underwent routine phacoemulsification surgery with single-piece acrylic IOL implantation (A constant = 118.8). Outcomes of multiple formulas were calculated. Included formulas were SRK/T, Holladay 1, Holladay 2, Haigis, Barrett True-K, Haigis and Barrett True-K (target refraction of 0.50 D), Barrett Universal II, Kane, PEARL-DGS, Shammas no history, DK SRK/T, DK SRK/T (target refraction of 0.50 D), Double K (DK) Holladay 1, and DK Holladay 1 (target refraction of 0.50 D). Averages of multiple combinations of best-performing single formulas were calculated. Primary outcome is mean absolute error (MAE).Results: Haigis (with -0.50 D target refraction) and DK SRK/T showed the lowest mean and median absolute errors (MedAE) followed by Haigis, Barrett True-K, and Barrett True-K (with -0.50 D target refraction). Combinations of 3, 4, or 5 of best performing single formulas yielded good results with >60% of cases within +0.50 D of intended refraction and MAE around 0.50 D. The best performing formulas with flatter K readings were PEARL-DGS and Haigis (with additional -0.50 D target refraction) with MAE of 0.72 + 0.71 D and 0.70 + 0.70 D, respectively, followed by Barrett True-K (with intended -0.50 D target refraction) with MAE of 0.75 + 0.63 D.Conclusion: Using an average of three or more Haigis (with -0.50 D target refraction), the Barrett True-K, DK Holladay 1, and DK SRK/T formulas showed better outcomes than using a single formula for IOLMaster 700 standard K readings. The PEARL-DGS formula showed better accuracy in eyes with flatter K readings (<38 D).
引用
收藏
页码:2589 / 2597
页数:9
相关论文
共 50 条
  • [1] Prediction Accuracy of Total Keratometry Compared to Standard Keratometry Using Different Intraocular Lens Power Formulas
    Fabian, Ekkehard
    Wehner, Wolfram
    JOURNAL OF REFRACTIVE SURGERY, 2019, 35 (06) : 362 - 369
  • [2] Effect of Posterior Keratometry on the Accuracy of 10 Intraocular Lens Calculation Formulas: Standard Keratometry versus Total Keratometry
    Jin, Aixia
    Zhang, Jiaqing
    Tan, Xuhua
    Jin, Kangxin
    Zhang, Yifan
    Han, Xiaotong
    Chen, Xiaoyun
    Jin, Guangming
    Luo, Lixia
    Liu, Yizhi
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2024, 262 (06) : 1829 - 1838
  • [3] Effect of Posterior Keratometry on the Accuracy of 10 Intraocular Lens Calculation Formulas: Standard Keratometry versus Total Keratometry
    Aixia Jin
    Jiaqing Zhang
    Xuhua Tan
    Kangxin Jin
    Yifan Zhang
    Xiaotong Han
    Xiaoyun Chen
    Guangming Jin
    Lixia Luo
    Yizhi Liu
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2024, 262 : 1829 - 1838
  • [4] Comparison of the accuracy of three intraocular lens power calculation formulas in cataract patients with prior radial keratotomy
    Li, Meng
    Wang, Jin-Da
    Zhang, Jing-Shang
    Mao, Ying-Yan
    Cao, Kai
    Wan, Xiu-Hua
    EUROPEAN JOURNAL OF MEDICAL RESEARCH, 2023, 28 (01)
  • [5] Comparison of the accuracy of three intraocular lens power calculation formulas in cataract patients with prior radial keratotomy
    Meng Li
    Jin-Da Wang
    Jing-Shang Zhang
    Ying-Yan Mao
    Kai Cao
    Xiu-Hua Wan
    European Journal of Medical Research, 28
  • [6] Accuracy of Modern and Traditional Intraocular Lens Power Calculation Formulas in Pediatric Cataract Surgery
    Helaly, Hany Ahmed
    Said, Mohamed Hassan
    Elnaggar, Osama Ramadan
    Elkhawaga, Mohamed Hassan
    CLINICAL OPHTHALMOLOGY, 2024, 18 : 1761 - 1769
  • [7] CALCULATION OF INTRAOCULAR-LENS POWER AFTER RADIAL KERATOTOMY WITH COMPUTERIZED VIDEOKERATOGRAPHY
    CELIKKOL, L
    PAVLOPOULOS, G
    WEINSTEIN, B
    CELIKKOL, G
    FELDMAN, ST
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 1995, 120 (06) : 739 - 750
  • [8] Accuracy of refractive outcomes using standard or total keratometry for intraocular lens power formulas in conventional cataract surgery
    Zhao, He
    Chen, Xu
    Liu, Bo
    Liu, Xi
    Liu, Yong
    BMC OPHTHALMOLOGY, 2023, 23 (01)
  • [9] Accuracy of refractive outcomes using standard or total keratometry for intraocular lens power formulas in conventional cataract surgery
    He Zhao
    Xu Chen
    Bo Liu
    Xi Liu
    Yong Liu
    BMC Ophthalmology, 23 (1)
  • [10] Intraocular lens power calculation after radial keratotomy: Estimating the refractive corneal power
    Awwad, Shady T.
    Dwarakanathan, Surendar
    Bowman, R. Wayne
    Cavanagh, H. Dwight
    Verity, Steven M.
    Mootha, Vinod V.
    McCulley, James P.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (06): : 1045 - 1050