Deep eutectic solvent-based electromembrane hollow fiber liquid phase microextraction for determining Pb in water and food samples

被引:22
作者
Chaikhan, Pilaipan [1 ]
Udnan, Yuthapong [1 ,2 ]
Ampiah-Bonney, Richmond J. [3 ]
Chaiyasith, Wipharat Chuachuad [1 ,2 ]
机构
[1] Naresuan Univ, Fac Sci, Dept Chem, Phitsanulok 65000, Thailand
[2] Naresuan Univ, Fac Sci, Ctr Excellence Petr & Petrochem & Adv Mat, Phitsanulok 65000, Thailand
[3] Amherst Coll, A205 Sci Ctr, Dept Chem, Amherst, MA 01002 USA
关键词
Electro-assisted; Electromembrane; Deep eutectic solvent; Hollow fiber liquid phase microextraction; Lead; Graphite furnace atomic absorption; spectrometry; ATOMIC-ABSORPTION-SPECTROMETRY; SPECTROPHOTOMETRIC DETERMINATION; ENVIRONMENTAL-SAMPLES; ORGANIC SALT; EXTRACTION; LEAD; CADMIUM; SPECIATION; PRECONCENTRATION; SELENIUM;
D O I
10.1016/j.jfca.2023.105214
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
In the present work, the determination of Pb using the electromembrane hollow fiber liquid phase micro -extraction with a deep eutectic solvent and graphite furnace atomic absorption spectrometry detection (DES-EM-HFLPME-GFAAS) was proposed. First, Pb(II) in the sample was converted to the anionic form of Pb-oxyanion under alkali conditions. Then, the electro-assisted technique was applied to facilitate the anion passing through the supported liquid membrane into the phase of deep eutectic solvent mixed with buffer solution. Finally, GFAAS was applied for monitoring the total lead in samples. The important parameters affecting the method efficiency were studied. Under optimized conditions, the linear range was observed in the range 0.036-1.0 ng/mL. The limit of detection and limit of quantitation were 0.011 and 0.036 ng/mL, respectively. Precision as %RSD was obtained from 1.03% to 3.49%. The enrichment factor and the preconcentration factor were 111 and 750, respectively. The proposed method was applied to determine lead in water and food samples (i.e., drinking and tap water, canned food, and vegetables) with acceptable recoveries from 86.70% to 116.0%. The method was successfully applied to determine the amount of lead in the standard reference materials, and the concentrations measured were not significantly different at 95% of confidence level from the certified values.
引用
收藏
页数:9
相关论文
共 53 条
[31]   Hollow fiber based liquid-phase microextraction for the determination of mercury traces in water samples by electrothermal atomic absorption spectrometry [J].
Lopez-Garcia, Ignacio ;
Rivas, Ricardo E. ;
Hernandez-Cordoba, Manuel .
ANALYTICA CHIMICA ACTA, 2012, 743 :69-74
[32]   Hydrophobic deep eutectic solvents in microextraction techniques-A review [J].
Makos, Patrycja ;
Slupek, Edyta ;
Gebicki, Jacek .
MICROCHEMICAL JOURNAL, 2020, 152
[33]   Switchable solvent based green liquid phase microextraction method for cobalt in tobacco and food samples prior to flame atomic absorption spectrometric determination [J].
Memon, Zainab Manzoor ;
Yilmaz, Erkan ;
Soylak, Mustafa .
JOURNAL OF MOLECULAR LIQUIDS, 2017, 229 :459-464
[34]   A simple method of the recovery of selenium from food samples for the determination by ICP-MS [J].
Ohki, Akira ;
Nakajima, Tsunenori ;
Hirakawa, Shota ;
Hayashi, Kentaro ;
Takanashi, Hirokazu .
MICROCHEMICAL JOURNAL, 2016, 124 :693-698
[35]   Simultaneous stripping detection of Zn(II), Cd(II) and Pb(II) using a bimetallic Hg-Bi/single-walled carbon nanotubes composite electrode [J].
Ouyang, Ruizhuo ;
Zhu, Zhenqian ;
Tatum, Clarissa E. ;
Chambers, James Q. ;
Xue, Zi-Ling .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2011, 656 (1-2) :78-84
[36]   Preparation of a magnetic sorbent based on Tanacetum extract and its application in the extraction of Cu(II) and Pb(II) ions from milk performed in a narrow-bore tube followed by dispersive liquid-liquid microextraction [J].
Parvizzad, Kosar ;
Sorouraddin, Saeed Mohammad ;
Farajzadeh, Mir Ali .
JOURNAL OF FOOD COMPOSITION AND ANALYSIS, 2022, 112
[37]  
PCD, 1991, WATER QUAL STAND
[38]   Speciation of chromium in environmental samples by dual electromembrane extraction system followed by high performance liquid chromatography [J].
Safari, Meysam ;
Nojavan, Saeed ;
Davarani, Saied Saeed Hosseiny ;
Morteza-Najarian, Amin .
ANALYTICA CHIMICA ACTA, 2013, 789 :58-64
[39]   Application of hollow fiber liquid phase microextraction and dispersive liquid-liquid microextraction techniques in analytical toxicology [J].
Sharifi, Vahid ;
Abbasi, Ali ;
Nosrati, Anahita .
JOURNAL OF FOOD AND DRUG ANALYSIS, 2016, 24 (02) :264-276
[40]   The interactions of metal cations and oxyanions with protein tyrosine phosphatase 1B [J].
Singh, Kshetrimayum Birla ;
Maret, Wolfgang .
BIOMETALS, 2017, 30 (04) :517-527