Local diagnostic reference levels for paediatric chest computed tomography in Morocco

被引:3
作者
Benmessaoud, Mounir [1 ]
Dadouch, Ahmed [1 ]
Maghnouj, Abdelmajid [1 ]
Lemmassi, Assiya [2 ]
Ouaggou, Ibrahim Ait [3 ]
Ouhadda, Hassan [4 ]
El-Ouardi, Youssef [1 ]
机构
[1] Sidi Mohamed Ben Abdellah Univ, Fac Sci Dhar Mahraz, Fes 30000, Morocco
[2] Sidi Mohamed Ben Abdellah Univ, Higher Sch Technol, Fes 30000, Morocco
[3] Univ Mohammed First, Natl Sch Appl Sci, Oujda 60000, Morocco
[4] Univ Mohammed First, Fac Sci, Oujda 60000, Morocco
关键词
Diagnostic reference levels; Computed tomography; Paediatric chest; Size specific dose estimates; ITERATIVE RECONSTRUCTION; UNIVERSITY HOSPITALS; RADIATION-EXPOSURE; CT; SIZE; STRATEGIES; ACCURACY; PHANTOM;
D O I
10.1016/j.radphyschem.2023.110794
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The present study aimed to establish the local diagnostic reference levels (LDRLs) for paediatric chest computed tomography examinations in Morocco. The data were collected retrospectively from three university hospitals during a two-year period. The proposed LDRLs were expressed in terms of volume CT dose index (CTDIvol), dose-length product (DLP) per series, DLP per procedure, and size-specific dose estimates (SSDE). The effective diameter method was used to estimate SSDE conversion factors based on the middle slice of the scan series. A total of 489 procedures were enrolled including 74% of multiphase scans and 26% of a single series. The LDRLs in terms of CTDIvol (mGy) were 9.5, 9.5, 9.8, and 10.3 for <1 year, 1-<5 years, 5-<10 years, and 10-<15 years age groups, respectively. The LDRLs in terms of DLP (mGy.cm) per series were 188, 243, 276, and 316. In terms of DLP (mGy.cm) per procedure were 373, 491, 583, and 633. The corresponding LDRLs in terms of SSDE (mGy) were 24.4, 21.1, 20.3, and 19 respectively for the four age groups. The findings shed light on higher values compared to international studies for all age groups included.
引用
收藏
页数:9
相关论文
共 43 条
  • [1] AAPM, 2011, SIZE SPECIFIC DOSE E, P1
  • [2] AAPM, 2014, 220 AAPM TG
  • [3] Evaluation of age-based radiation dose in paediatric patients received from head CT examination at a tertiary hospital, Nigeria
    Abdulkadir, Muhammad Kabir
    Izge, Iliyasu Yusuf
    Yunusa, Garba Haruna
    Mohammed, Abacha
    Osman, Noor Diyana
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2021, 182
  • [4] Dose optimisation in paediatric CT examination: Assessment on current scanning protocols associated with radiation dose
    Abdulkadir, Muhammad Kabir
    Rahim, Nur Atikah Yusra Mat
    Mazlan, Nur Syazwani
    Daud, Norfataha Mohd
    Shuaib, Ibrahim Lutfi
    Osman, Noor Diyana
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2020, 171
  • [5] Estimation of size-specific dose estimates (SSDE) for paediatric and adults patients based on a single slice
    Abuhaimed, Abdullah
    Martin, Colin J.
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2020, 74 : 30 - 39
  • [6] Admontree S., 2019, Naresuan Univ J: Sci Technol, V27, P28, DOI 10.14456/nujst.2019.14
  • [7] Correlation of Chest CT and RT-PCR Testing for Coronavirus Disease 2019 (COVID-19) in China: A Report of 1014 Cases
    Ai, Tao
    Yang, Zhenlu
    Hou, Hongyan
    Zhan, Chenao
    Chen, Chong
    Lv, Wenzhi
    Tao, Qian
    Sun, Ziyong
    Xia, Liming
    [J]. RADIOLOGY, 2020, 296 (02) : E32 - E40
  • [8] Pediatric Computed Tomography Dose Optimization Strategies: A Literature Review
    Al Mahrooqi, Khalid Mohammed Salim
    Ng, Curtise Kin Cheung
    Sun, Zhonghua
    [J]. JOURNAL OF MEDICAL IMAGING AND RADIATION SCIENCES, 2015, 46 (02) : 241 - 249
  • [9] Survey of paediatric imaging exposure from computed tomography examinations
    Alkhorayef, M.
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2020, 167
  • [10] RADIATION DOSE DETERMINATION IN ABDOMINAL CT EXAMINATIONS OF CHILDREN AT SUDANESE HOSPITALS USING SIZE-SPECIFIC DOSE ESTIMATES
    Bashier, Einas H.
    Suliman, I. I.
    [J]. RADIATION PROTECTION DOSIMETRY, 2019, 183 (04) : 444 - 449