Comparison of mouth rinsing performance between adults and children using a contactless vital sensing camera

被引:1
作者
Kanada, Hisako [1 ]
Yamamoto, Yushi [1 ]
Sato, Hideo [2 ]
Chinju, Kohei [1 ]
Ariyasu, Yuichi [1 ]
Kawaji, Maria [1 ]
Iwashita, Yoichiro [3 ]
Hashiguchi, Makiko [1 ]
Yamasaki, Youichi [1 ]
机构
[1] Kagoshima Univ, Grad Sch Med & Dent Sci, Dept Pediat Dent, Kagoshima, Japan
[2] Kagoshima Univ Hosp, Dept Pediat Dent, 8-35-1 Sakuragaoka, Kagoshima, Kagoshima 8908544, Japan
[3] Kagoshima Univ, Grad Sch Med & Dent Sci, Dept Dent Educ, Kagoshima, Japan
关键词
adult and child; lip motion; mouse rinsing; oral function development; vital sensing camera; CEREBRAL-PALSY; MOVEMENT;
D O I
10.1111/joor.13379
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Background Evaluating mouth rinsing skills is useful for assessing oral function, however current evaluation methods are subjective. Objectives This study compared mouth rinsing between adults and children using a contactless camera to capture lip motion. Methods The subjects comprised 16 adults and 13 children with no oral dysfunction. A compact vital sensing camera adapted from a Microsoft Xbox One Kinect Sensor (R) (Kinect) was placed 100 cm from the floor and 120 cm from the subject; 5, 10 and 15 ml of water were used as samples. Participants were instructed to hold the sample in the oral cavity, close the lips and move the sample alternatively left and right for 15 s. Maximum/minimum displacement from the reference plane and rinsing cycle for each sample were analysed by one-way analysis of variance. Results In adults, there was no significant difference in the maximum/minimum displacement between the left and right sides of the angulus oris due to differences in sample amount. In children, the right maximum significantly differed between the 5- and 15-ml and 10- and 15-ml samples, while the left maximum significantly differed between the 5- and 10-ml and 5- and 15-ml samples. The right minimum significantly differed between the 5- and 10-ml samples, as did the duration of mouth rinsing between the 5- and 15-ml samples. Conclusions In children, lip movement and mouth rinsing duration tended to decrease with increasing sample volume. Evaluating lip movement using a contactless vital sensing camera is useful for assessing children's development of oral function.
引用
收藏
页码:76 / 86
页数:11
相关论文
共 23 条
[1]  
[Anonymous], KIN WIND DEV RES HUM
[2]   Feeding children with cerebral palsy and swallowing difficulties [J].
Arvedson, J. C. .
EUROPEAN JOURNAL OF CLINICAL NUTRITION, 2013, 67 :S9-S12
[3]  
Arvedson J C., 2019, Pediatric swallowing and feeding: assessment and management
[4]  
Ayano R, 2000, Int J Orofacial Myology, V26, P24
[5]   Determination of the precision and accuracy of morphological measurements using the Kinect™ sensor: comparison with standard stereophotogrammetry [J].
Bonnechere, B. ;
Jansen, B. ;
Salvia, P. ;
Bouzahouene, H. ;
Sholukha, V. ;
Cornelis, J. ;
Rooze, M. ;
Jan, S. Van Sint .
ERGONOMICS, 2014, 57 (04) :622-631
[6]   The relationship between body balance and occlusal balance of Japanese children during the deciduous dentition period [J].
Du, Xiaopei ;
Ogata, Sagiri ;
Ji, Ying ;
Rodis, Omar M. M. ;
Matsumura, Seishi ;
Shimono, Tsutomu .
PEDIATRIC DENTAL JOURNAL, 2009, 19 (01) :52-57
[7]   Speech-associated labiomandibular movement in Mandarin-speaking children with quadriplegic cerebral palsy: A kinematic study [J].
Hong, Wei-Hsien ;
Chen, Hsieh-Ching ;
Yang, Fan-pei Gloria ;
Wu, Ching-Yi ;
Chen, Chia-Ling ;
Wong, Alice May-kuen .
RESEARCH IN DEVELOPMENTAL DISABILITIES, 2011, 32 (06) :2595-2601
[8]   Validity and reliability of Kinect skeleton for measuring shoulder joint angles: a feasibility study [J].
Huber, M. E. ;
Seitz, A. L. ;
Leeser, M. ;
Sternad, D. .
PHYSIOTHERAPY, 2015, 101 (04) :389-393
[9]   Anatomical, functional, physiological and behavioural aspects of the development of mastication in early childhood [J].
Le Reverend, Benjamin J. D. ;
Edelson, Lisa R. ;
Loret, Chrystel .
BRITISH JOURNAL OF NUTRITION, 2014, 111 (03) :403-414
[10]  
Lee K, 2009, GLOB INST, P1