Diagnostic Value of Carotid Plaque Assessment with AIS Based on Quantitative Parameters of Dual-Layer Detector Spectral CT

被引:0
|
作者
Meng, Xiaoying [1 ]
Li, Fei [1 ]
Wu, Wenpei [2 ]
Wu, Juncang [1 ,3 ]
机构
[1] Anhui Med Univ, Hefei Hosp, Hefei Peoples Hosp 2, Dept Neurol, Hefei 230011, Anhui, Peoples R China
[2] Anhui Med Univ, Clin Sch Med 5, Hefei 230032, Anhui, Peoples R China
[3] Bengbu Med Coll, Hefei Peoples Hosp 2, Dept Neurol, Hefei 230011, Anhui, Peoples R China
关键词
ischemic stroke; carotid plaque; spectral CT; effective atomic number; iodine density values; anhydrous iodine values; electron density; ISCHEMIC-STROKE; RISK-FACTORS; ENERGY CT; MATRIX-METALLOPROTEINASE-9; LESIONS; BURDEN; ARTERY;
D O I
10.2147/IJGM.S448852
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose: To investigate the quantitative assessment of carotid plaque by each parameter of dual-layer detector spectral CT and its diagnostic value in patients with acute cerebral infarction. Patients and Methods: Eighty-three patients with carotid atherosclerotic plaques who underwent spectral CT scanning were retrospectively included. Forty-two patients with acute ischaemic stroke (AIS) were included in the study group, and 41 patients without AIS were included in the control group. We compared the detection of carotid plaques in the two groups and the differences in the spectral quantitative parameters of the plaques in the two groups, and their diagnostic efficacy was obtained. Results: The detection rate of carotid plaques in the AIS group was higher than that in the non-AIS group (p<0.05); the carotid plaques in the AIS group mainly consisted of non-calcified plaques, while those in the non-AIS group mainly consisted of calcified plaques. The effective atomic number (Zeff), slope of the energy spectrum curve (lambda H), electron density (ED), and iodine-no-water value of the carotid plaques in the AIS group were lower than those in the non-AIS (p<0.05). For the differentiation of the carotid plaques in the AIS group from those in the non-AIS group, the area under the curve (AUC) of Zeff amounted to 0.637 (cut-off value: 11.865; sensitivity: 72.5%; specificity: 56.2%), the AUC of lambda H amounted to 0.628 (cut-off value: 19.56; sensitivity: 76.3%; specificity: 51.6%), and that for ED amounted to 0.624 (cut-off value: 110.45; sensitivity: 60.0%; specificity: 64.1%), AUC of iodine-no-water value amounted to 0.645 (cut-off value: 9.125; sensitivity: 61.3%; specificity: 65.6%). Conclusion: In summary, the quantitative parameters of dual-layer detector spectral CT can be used to assess plaque stability and have certain value in the diagnosis of AIS. The quantitative parameters can effectively differentiate carotid plaques in AIS and non-AIS patients.
引用
收藏
页码:1263 / 1272
页数:10
相关论文
共 50 条
  • [31] The diagnostic value of dual-layer CT in the assessment of lymph nodes in lymphoma patients with PET/CT as a reference standard
    Zhengwu Tan
    Heng Mei
    Chunxia Qin
    Xiao Zhang
    Ming Yang
    Lan Zhang
    Jing Wang
    Scientific Reports, 13
  • [32] Right Ventricular Extracellular Volume with Dual-Layer Spectral Detector CT: Value in Chronic Thromboembolic Pulmonary Hypertension
    Yamasaki, Yuzo
    Abe, Kohtaro
    Kamitani, Takeshi
    Sagiyama, Koji
    Hida, Tomoyuki
    Hosokawa, Kazuya
    Matsuura, Yuko
    Hioki, Kazuhito
    Nagao, Michinobu
    Yabuuchi, Hidetake
    Ishigami, Kousei
    RADIOLOGY, 2021, 298 (03) : 589 - 596
  • [33] Diagnostic value of non-contrast electron density imaging using dual-layer spectral detector CT for small gastric stromal tumors
    Qi, Liping
    Gui, Shen
    Zhong, Zhilin
    Chen, Xianfeng
    DIGESTIVE AND LIVER DISEASE, 2025, 57 (04) : 927 - 928
  • [34] The value of dual-layer spectral detector CT in preoperative T staging of laryngeal and hypopharyngeal squamous cell carcinoma
    Zheng, Ting
    Xiao, Yan
    Yang, Fan
    Dai, Guidong
    Wang, Fang
    Chen, Guangxiang
    EUROPEAN JOURNAL OF RADIOLOGY, 2024, 171
  • [35] Effect of CT Acquisition Parameters on Iodine Density Measurement at Dual-Layer Spectral CT
    Kim, Hyungjin
    Park, Chang Min
    Kang, Chang Kyung
    Yoon, Jinyeong
    Chae, Kum Ju
    Goo, Jin Mo
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2018, 211 (04) : 748 - 754
  • [36] Diagnosis of benign and malignant thyroid nodules by a dual-layer spectral detector CT-based nomogram
    Yi, Rongqi
    Li, Ting
    Xie, Gang
    Li, Kang
    FRONTIERS IN ONCOLOGY, 2023, 13
  • [37] Evaluation of peri-plaque pericoronary adipose tissue attenuation in coronary atherosclerosis using a dual-layer spectral detector CT
    Jia, Yulin
    Zou, Lei
    Xue, Ming
    Zhang, Xiaoyu
    Xiao, Xigang
    FRONTIERS IN MEDICINE, 2024, 11
  • [38] Unenhanced Dual-Layer Spectral-Detector CT for Characterizing Indeterminate Adrenal Lesions
    Nagayama, Yasunori
    Inoue, Taihei
    Oda, Seitaro
    Tanoue, Shota
    Nakaura, Takeshi
    Morinaga, Jun
    Ikeda, Osamu
    Hirai, Toshinori
    RADIOLOGY, 2021, 301 (02) : 369 - 378
  • [39] Quantitative evaluation of extracellular volume in patients with heart failure using dual-layer spectral detector CT: a feasibility study
    刘珮君
    ChinaMedicalAbstracts(InternalMedicine), 2022, 39 (01) : 1 - 1
  • [40] Early rectal neoplasm in dual-layer spectral detector computed tomography: dual-layer spectral computed tomography (CT) images improve tumor detection and staging
    Pan, Xuelin
    Wu, Zhihan
    Zhao, Jin
    Zhang, Xinyi
    Zhang, Xiaodi
    Tang, Li
    Yang, Jinlin
    Deng, Kai
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2024, 14 (12) : 8260 - 8271