A novel technique of a new cannulated screw for treatment of inferior pole patellar fractures: a finite element study

被引:1
作者
Pan, Mingmang [1 ]
Yin, Nuo [1 ]
Du, Li [1 ]
Xue, Feng [1 ]
Shen, Yuchun [1 ]
Ding, Liang [1 ]
机构
[1] Shanghai Jiao Tong Univ, Shanghai Fengxian Cent Hosp, Dept Orthopaed, Affiliated Peoples Hosp 6, South Campus, Shanghai 201499, Peoples R China
关键词
Patellar fracture; Inferior pole; Finite element; Ding's screw; INTERNAL-FIXATION; OPEN REDUCTION;
D O I
10.1186/s13018-023-04299-y
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective We invented a new cannulated screw with holes on the tail, which called Ding's screw. The goal of this study was to evaluate the biomechanical outcomes of this new screw with tension band wiring for the treatment of inferior pole patellar fractures in a finite element model.Methods We conducted a finite element biomechanical study using two fixation methods: Ding's screw and tension band wiring (DSTBW) and cannulated screws and tension band wiring (CSTBW). Two methods were simulated to fix the inferior pole patellar fracture in a finite element model. The relative displacement and stress distribution were analyzed and compared.Result There were less displacement and stress distribution of DSTBW in different knee movement (30 degrees, 60 degrees, 90 degrees, 120 degrees) when compared to CSTBW. The highest value of displacement of the fracture and von Mises stress of the internal fixation happened in 120 degrees knee movement in both groups. The highest displacement of the DSTBW was less than that of the CSTBW (1.92 mm to 2.12 mm). The highest value of the stress on the screws was 110.60 MPa in DSTBW group, and 132.90 MPa in CSTBW group. The highest value of the stress on the titanium cable was 38.51 MPa in DSTBW group, and 41.91 MPa in CSTBW group.Conclusion DSTBW fixation provides more stability than CSTBW fixation model in a finite element study.
引用
收藏
页数:7
相关论文
共 17 条
  • [1] Fracture of the Inferior Pole of the Patella
    Allen, Chris
    Jim, Lisa M.
    [J]. JOURNAL OF ORTHOPAEDIC & SPORTS PHYSICAL THERAPY, 2012, 42 (07) : 658 - 658
  • [2] Stress distribution of single-implant-retained overdenture reinforced with a framework: A finite element analysis study
    Amaral, Camilla F.
    Gomes, Rafael S.
    Rodrigues Garcia, Renata C. M.
    Del Bel Cury, Altair A.
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2018, 119 (05) : 791 - 796
  • [3] Biomechanical evaluation of current patella fracture fixation techniques
    Carpenter, JE
    Kasman, RA
    Patel, N
    Lee, ML
    Goldstein, SA
    [J]. JOURNAL OF ORTHOPAEDIC TRAUMA, 1997, 11 (05) : 351 - 356
  • [4] Open Reduction and Internal Fixation of Displaced Patella Inferior Pole Fractures With Anterior Tension Band Wiring Through Cannulated Screws
    Chang, Shi-Min
    Ji, Xiang-Ling
    [J]. JOURNAL OF ORTHOPAEDIC TRAUMA, 2011, 25 (06) : 366 - 370
  • [5] Cibula Z, 2018, Rozhl Chir, V97, P473
  • [6] The effect of Ding?s screws and tension band wiring for treatment of inferior pole patellar fractures
    Du, Li
    Yin, Nuo
    Pan, Mingmang
    Xue, Feng
    Shen, Yuchun
    Ding, Liang
    [J]. INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2023, 54 (04): : 1198 - 1202
  • [7] Biomechanical Properties of Suture Anchor Repair Compared With Transosseous Sutures in Patellar Tendon Ruptures A Cadaveric Study
    Ettinger, Max
    Dratzidis, Antonios
    Hurschler, Christof
    Brand, Stephan
    Calliess, Tilman
    Krettek, Christian
    Jagodzinski, Michael
    Petri, Maximilian
    [J]. AMERICAN JOURNAL OF SPORTS MEDICINE, 2013, 41 (11) : 2540 - 2544
  • [8] Modified Technique of Separate Vertical Wiring for the Fixation of Patellar Inferior Pole Fracture
    He, Shuangjian
    Huang, Xiaoyi
    Yan, Bin
    Zhu, Jian
    Bao, Nirong
    Zhao, Jianning
    [J]. JOURNAL OF ORTHOPAEDIC TRAUMA, 2018, 32 (04) : e145 - e150
  • [9] Anchor suture fixation of distal pole fractures of patella: twenty seven cases and comparison to partial patellectomy
    Kadar, Assaf
    Sherman, Haggai
    Drexler, Michael
    Katz, Eldad
    Steinberg, Ely L.
    [J]. INTERNATIONAL ORTHOPAEDICS, 2016, 40 (01) : 149 - 154
  • [10] Microstructural evolution and mechanical property of Ti-6Al-4V wall deposited by continuous plasma arc additive manufacturing without post heat treatment
    Lin, Jianjun
    Lv, Yaohui
    Liu, Yuxin
    Sun, Zhe
    Wang, Kaibo
    Li, Zhuguo
    Wu, Yixiong
    Xu, Binshi
    [J]. JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2017, 69 : 19 - 29