Probing the Influence of Hybrid Thread Design on Biomechanical Response of Dental Implants: Finite Element Study and Experimental Validation

被引:7
|
作者
Chakraborty, Arindam [1 ]
Sahare, Kalash Darshan [1 ]
Datta, Pallab [2 ]
Majumder, Santanu [1 ]
Roychowdhury, Amit [1 ]
Basu, Bikramjit [3 ]
机构
[1] Indian Inst Engn Sci & Technol, Dept Aerosp Engn & Appl Mech, PO Bot Garden, Howrah 711103, W Bengal, India
[2] Natl Inst Pharmaceut Educ & Res, Dept Pharmaceut, Kolkata 700054, W Bengal, India
[3] Indian Inst Sci, Mat Res Ctr, Bengaluru 560012, Karnataka, India
来源
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME | 2023年 / 145卷 / 01期
关键词
dental implant design; thread design; finite element analysis; bone/implant contact; initial stability; additive manufacturing; STRESS-DISTRIBUTION; BONE TISSUE; OSSEOINTEGRATION; GEOMETRY; STABILITY; TORQUE;
D O I
10.1115/1.4054984
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
This study aimed to perform quantitative biomechanical analysis for probing the effect of varying thread shapes in an implant for improved primary stability in prosthodontics surgery. Dental implants were designed with square (SQR), buttress (BUT), and triangular (TRI) thread shapes or their combinations. Cone-beam computed tomography images of mandible molar zones in human subjects belonging to three age groups were used for virtual implantation of the designed implants, to quantify patient-specific peri-implant bone microstrain, using finite element analyses. The in silico analyses were carried out considering frictional contact to simulate immediate loading with a static masticatory force of 200 N. To validate computational biomechanics results, compression tests were performed on three-dimensional printed implants having the investigated thread architectures. Bone/implant contact areas were also quantitatively assessed. It was observed that, bone/implant contact was maximum for SQR implants followed by BUT and TRI implants. For all the cases, peak microstrain was recorded in the cervical cortical bone. The combination of different thread shapes in the middle or in the apical part (or both) was demonstrated to improve peri-implant microstrain, particularly for BUT and TRI. Considering 1500-2000 microstrain generates in the peri-implant bone during regular physiological functioning, BUT-SQR, BUT-TRI-SQR, TRI-SQR-BUT, SQR, and SQR-BUT-TRI design concepts were suitable for younger; BUT-TRI-SQR, BUT-SQR-TRI, TRI-SQR-BUT, SQR-BUT, SQR-TRI for middle-aged, and BUT-TRI-SQR, BUT-SQR-TRI, TRI-BUT-SQR, SQR, and SQR-TRI for the older group of human patients.
引用
收藏
页数:12
相关论文
共 50 条
  • [41] Biomechanical evaluation of one-piece and two-piece small-diameter dental implants: In-vitro experimental and three-dimensional finite element analyses
    Wu, Aaron Yu-Jen
    Hsu, Jui-Ting
    Chee, Winston
    Lin, Yun-Te
    Fuh, Lih-Jyh
    Huang, Heng-Li
    JOURNAL OF THE FORMOSAN MEDICAL ASSOCIATION, 2016, 115 (09) : 794 - 800
  • [42] Influence of vertical misfit in screw fatigue behavior in dental implants: A three-dimensional finite element approach
    Abasolo, Mikel
    Aguirrebeitia, Josu
    Vallejo, Javier
    Albizuri, Joseba
    Coria, Ibai
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2018, 232 (11) : 1117 - 1128
  • [43] Mouthguard Biomechanics for Protecting Dental Implants from Impact: Experimental and Finite Element Impact Analysis
    Carvalho, Valessa F.
    Soares, Priscilla B. F.
    Verissimo, Crisnicaw
    Pessoa, Roberto S.
    Versluis, Antheunis
    Soares, Carlos J.
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2018, 33 (02) : 335 - 343
  • [44] Biomechanical Analysis of Functionally Graded Root Analog Implants on Alveolar Bone: A 3D Finite Element Study
    Wang, Feilong
    Jiang, Zhaoliang
    Si, Pengchao
    Lan, Jing
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2021, 36 (04) : E63 - E71
  • [45] Development of patient-specific finite element model for study of composite dental implants
    Gupta, Vivek
    Garg, Anshika
    Tewari, Nitesh
    Srivastav, Sukeshana
    Chanda, Arnab
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2024, 10 (02)
  • [46] Interactive Effects of Five Dental Implant Design Parameters on the Peak Strains at the Interfacial Bone: A Finite Element Study
    Sheikhan, Erfan
    Kadkhodazadeh, Mahdi
    Amid, Reza
    Lafzi, Ali
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2022, 37 (02) : 302 - 310
  • [47] Biomechanical 3-Dimensional Finite Element Analysis of Obturator Protheses Retained with Zygomatic and Dental Implants in Maxillary Defects
    Akay, Canan
    Yalug, Suat
    MEDICAL SCIENCE MONITOR, 2015, 21 : 604 - 611
  • [48] Number of pegs influence focal stress distributions and micromotion in glenoid implants: a finite element study
    Wahab, Abdul Hadi Abdul
    Kadir, Mohammed Rafiq Abdul
    Harun, Muhammad Noor
    Kamarul, Tunku
    Syahrom, Ardiyansyah
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2017, 55 (03) : 439 - 447
  • [49] Comparative Study of the Influence of Dental Implant Design on the Stress and Strain Distribution using the Finite Element Method
    Sahai, Neha Srivastava
    Yadav, Divya
    Madhav, Srishti
    Kumar, Naveen
    Dubey, Anuradha
    Qadeer, Nazia
    Makkad, Ramanpal Singh
    JOURNAL OF PHARMACY AND BIOALLIED SCIENCES, 2024, 16 : S2776 - S2778
  • [50] Comparative study of stress characteristics in surrounding bone during insertion of dental implants of three different thread designs: A three-dimensional dynamic finite element study
    Udomsawat, Chaiwat
    Rungsiyakull, Pimduen
    Rungsiyakull, Chaiy
    Khongkhunthian, Pathawee
    CLINICAL AND EXPERIMENTAL DENTAL RESEARCH, 2019, 5 (01): : 26 - 37