Feasibility of size-specific organ-dose estimates based on water equivalent diameter for common head CT examinations: a Monte Carlo study

被引:0
|
作者
Tahiri, M. [1 ]
Benameur, Y. [1 ]
Mkimel, M. [1 ]
El Baydaoui, R. [1 ]
Mesardi, M. R. [1 ]
机构
[1] Hassan First Univ Settat, High Inst Hlth Sci, Lab Sci & Hlth Technol, Settat, Morocco
关键词
SSDE; Monte Carlo; water equivalent diameter; irradiated organs; organ dose; CHEST; SIMULATIONS; INDEX;
D O I
10.1088/1361-6498/acc1f0
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Computed tomography dose index (CTDI) is an unreliable dose estimate outside of the standard CTDI phantom diameters (16 and 32 cm). Size-specific dose estimate (SSDE) for head computed tomography (CT) examination was studied in the American Association of Physicists in Medicine Report 293 to provide SSDE coefficient factors based on water equivalent diameter as size metrics. However, it is limited to one protocol and for a fully irradiated organ. This study aimed to evaluate the dependency of normalized organ dose (ND) on water equivalent diameter as a size metric in three common protocols: routine head, paranasal sinus, and temporal bone. CTDIw measurements were performed for outlined protocols in the Siemens Emotion 16-slice-configuration scanner. Geant4 Application for Tomographic Emission Monte Carlo simulation platform, coupled with ten GSF patient models, was used to estimate organ doses. CT scanner system was modeled. Helical CT scans were simulated using constructor scan parameters and calculated scan lengths of each patient model. Organ doses provided by simulations were normalized to CTDIvol. The water equivalent diameters (D (w)) of patient models were obtained via relationships between D (w) and both effective diameter for a sample of patients' data.NDs received by fully, partially, and non-directly irradiated organs were then reported as a function of D (w). For fully irradiated organs, brain (R (2) > 0.92), eyes (R (2) > 0.88), and eye lens (R (2) > 0.89) correlate well with D (w). For the rest of the results, a poor correlation was observed. For partially irradiated organs, the exception was scalp (R (2) = 0.93) in temporal bone CT. For non-directly irradiated organs, the exception was thyroid (R (2) > 0.90) and lungs (R (2) > 0.91) in routine head CT. ND correlates well in routine head CT than other protocols. For the most part, no relationship seems to exist between R (2) and scan percentage coverage. The results have revealed additional factors that may influence the ND and D (w) relationship, which explains the need for more studies in the future to investigate the effect of scan conditions and organ anatomy variation.
引用
收藏
页数:10
相关论文
共 27 条
  • [1] Determination of water-equivalent diameter (Dw) and size-specific dose estimates (SSDE) for adult patients in abdominal CT examinations
    El Mansouri, M'hamed
    Tahiri, Zakaria
    Talbi, Mohammed
    Nhila, Oussama
    Sekkat, Hamza
    Choukri, Abdelmajid
    RADIATION EFFECTS AND DEFECTS IN SOLIDS, 2024, 179 (5-6): : 634 - 641
  • [2] Size-specific, scanner-independent organ dose estimates in contiguous axial and helical head CT examinations
    McMillan, Kyle
    Bostani, Maryam
    Cagnon, Chris
    Zankl, Maria
    Sepahdari, Ali R.
    McNitt-Gray, Michael
    MEDICAL PHYSICS, 2014, 41 (12)
  • [3] Radiation dose in chest CT: Assessment of size-specific dose estimates based on water-equivalent correction
    Gabusi, M.
    Riccardi, L.
    Aliberti, C.
    Vio, S.
    Paiusco, M.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2016, 32 (02): : 393 - 397
  • [4] An improved method for automated calculation of the water-equivalent diameter for estimating size-specific dose in CT
    Anam, Choirul
    Mahdani, Fahmi Rosydiansyah
    Dewi, Winda Kusuma
    Sutanto, Heri
    Triadyaksa, Pandji
    Haryanto, Freddy
    Dougherty, Geoff
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2021, 22 (09): : 313 - 323
  • [5] Size-Specific Dose Estimates Based on Water-Equivalent Diameter and Effective Diameter in Computed Tomography Coronary Angiography
    Xu, Jian
    Wang, Xiangquan
    Xiao, Huawei
    Xu, Jianguo
    MEDICAL SCIENCE MONITOR, 2019, 25 : 9299 - 9305
  • [6] THE SIZE-SPECIFIC DOSE ESTIMATE OF PAEDIATRIC HEAD CT EXAMINATIONS FOR VARIOUS PROTOCOLS
    Fahmi, Arif
    Anam, Choirul
    Ali, Mohd Hanafi
    RADIATION PROTECTION DOSIMETRY, 2020, 188 (04) : 522 - 528
  • [7] Advancing size-specific dose estimates in CT examinations: Dose estimates at longitudinal positions of scans
    Li, Xinhua
    Marschall, Theodore A.
    Yang, Kai
    Liu, Bob
    MEDICAL PHYSICS, 2022, 49 (02) : 1303 - 1311
  • [8] Institutional computed tomography diagnostic reference levels based on water-equivalent diameter and size-specific dose estimates
    Boos, Johannes
    Thomas, Christoph
    Appel, Elisabeth
    Klosterkemper, Yan
    Schleich, Christoph
    Aissa, Joel
    Bethge, Oliver Th
    Antoch, Gerald
    Kroepil, Patric
    JOURNAL OF RADIOLOGICAL PROTECTION, 2018, 38 (02) : 536 - 548
  • [9] Size specific dose estimates for adult patients in CT of the Kidney, Ureters, and Bladder (KUB) based on effective diameter and water equivalent diameter
    Alenazi, Khaled
    Alahmad, Haitham
    Albeshan, Salman
    Almeshari, Meshari
    Abanomy, Ahmad
    RADIATION PHYSICS AND CHEMISTRY, 2025, 229
  • [10] Establishment of baseline size-specific dose estimate (SSDE) for paediatric head computed tomography (CT) examinations
    Sulemana, Hamza
    Mumuni, Abdul Nashirudeen
    Abubakari, Izre-deen Osman Mohammed
    EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE, 2024, 55 (01):