Continuous Glucose Monitoring and Time in Range: Association with Adverse Outcomes among People with Type 2 or Gestational Diabetes Mellitus

被引:12
作者
Bitar, Ghamar [1 ,4 ]
Cornthwaite, Joycelyn A. [1 ]
Sadek, Sandra [1 ]
Ghorayeb, Tala [1 ]
Daye, Nahla [1 ]
Nazeer, Sarah [1 ]
Ghafir, Danna [1 ]
Cornthwaite, John [2 ]
Chauhan, Suneet P. [1 ]
Sibai, Baha M. [1 ]
Bartal, Michal Fishel [1 ,3 ]
机构
[1] Univ Texas Hlth Sci Ctr Houston, McGovern Med Sch, Dept Obstet & Gynecol, Div Maternal Fetal Med, Houston, TX USA
[2] Rice Univ, Dept Earth Environm & Planetary Sci, Houston, TX USA
[3] Tel Aviv Univ, Sheba Med Ctr Tel Hashomer, Sackler Sch Med, Dept Obstet & Gynecol, Tel Aviv, Israel
[4] Univ Texas Hlth Sci Ctr Houston, Dept Obstet & Gynecol & Reprod Sci, Houston, TX 77030 USA
关键词
diabetes; pregnancy; continuous glucose monitoring; time in range; neonatal outcomes; maternal outcomes; PREGNANT-WOMEN; GLYCEMIC CONTROL; RECOMMENDATIONS; HYPOGLYCEMIA; MANAGEMENT;
D O I
10.1055/s-0043-1764208
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Objective Continuous glucose monitoring (CGM) has become available for women with type 2 diabetes mellitus (T2DM) or gestational diabetes mellitus (GDM) during pregnancy. The recommended time in range (TIR, blood glucose 70-140 mg/dL) and its correlation with adverse pregnancy outcomes in this group is unknown. Our aim was to compare maternal and neonatal outcomes in pregnant people with T2DM or GDM with average CGM TIR values > 70 versus < 70%.Study Design We conducted a retrospective cohort study of all individuals using CGM during pregnancy from January 2017 to June 2022. Individuals with type 1 diabetes mellitus, or those missing CGM or delivery data were excluded. Primary composite neonatal outcome included any of the following: large for gestational age, NICU admission, need for intravenous glucose, respiratory support, or neonatal death. Secondary outcomes included other maternal and neonatal outcomes. Regression models were used to estimate adjusted odds ratio (aOR) and 95% confidence interval (CI).Results During the study period, 141 individuals with diabetes utilized CGM during pregnancy, with 65 (46%) meeting inclusion criteria. Of the study population, 28 (43%) had TIR < 70% and 37 (57%) had TIR > 70%. Compared with those with TIR > 70%, the primary composite outcome occurred more frequently in neonates of individuals TIR < 70% (71.4 vs. 37.8%, aOR: 4.8, 95% CI: 1.6, 15.7). Furthermore, individuals with TIR < 70% were more likely to have hypertensive disorders (42.9 vs. 16.2%, OR: 3.9, 95% CI: 1.3, 13.0), preterm delivery (54 vs. 27%, OR: 3.1, 95% CI: 1.1, 9.1), and cesarean delivery (96.4 vs. 51.4%, OR: 4.6, 95% CI: 2.2, 15.1) compared with those with TIR > 70%.Conclusion Among people with T2DM or GDM who utilized CGM during pregnancy, 4 out 10 individuals had TIR < 70% and, compared with those with TIR > 70%, they had a higher likelihood of adverse neonatal and maternal outcomes.
引用
收藏
页码:e1370 / e1377
页数:8
相关论文
共 50 条
  • [21] Characteristics of Continuous Glucose Monitoring Metrics in Persons with Type 1 and Type 2 Diabetes Treated with Multiple Daily Insulin Injections
    Hallstrom, Sara
    Hirsch, Irl B.
    Ekelund, Magnus
    Sofizadeh, Sheyda
    Albrektsson, Henrik
    Dahlqvist, Solveig
    Svensson, Ann-Marie
    Lind, Marcus
    DIABETES TECHNOLOGY & THERAPEUTICS, 2021, 23 (06) : 425 - 433
  • [22] Continuous glucose monitoring and insulin pump therapy in pregnant women with type 1 diabetes mellitus
    Lason, Izabela
    Cyganek, Katarzyna
    Witek, Przemyslaw
    Matejko, Bartlomiej
    Malecki, Maciej T.
    Skupien, Jan
    GINEKOLOGIA POLSKA, 2021, 92 (10) : 675 - 681
  • [23] Continuous glucose monitoring defined time-in-range is associated with sudomotor dysfunction in type 2 diabetes
    Guo, Qing-Yu
    Lu, Bin
    Guo, Zhan-Hong
    Feng, Zhou-Qin
    Yuan, Yan-Yu
    Jin, Xu-Guang
    Zang, Pu
    Gu, Ping
    Shao, Jia-Qing
    WORLD JOURNAL OF DIABETES, 2020, 11 (11) : 489 - 500
  • [24] Profiles of Intraday Glucose in Type 2 Diabetes and Their Association with Complications: An Analysis of Continuous Glucose Monitoring Data
    Varghese, Jithin Sam
    Ho, Joyce C.
    Anjana, Ranjit Mohan
    Pradeepa, Rajendra
    Patel, Shivani A.
    Jebarani, Saravanan
    Baskar, Viswanathan
    Narayan, K. M. Venkat
    Mohan, Viswanathan
    DIABETES TECHNOLOGY & THERAPEUTICS, 2021, 23 (08) : 555 - 564
  • [25] Study protocol: glycaemic outcomes in people with type 2 diabetes initiating continuous glucose monitoring: the 2GO-CGM study
    Lever, Claire S.
    Williman, Jonathan A.
    Boucsein, Alisa
    Watson, Antony
    Sampson, Rachael S.
    Sergel-Stringer, Oscar T.
    Keesing, Celeste
    Chepulis, Lynne
    Wheeler, Benjamin J.
    de Bock, Martin I.
    Paul, Ryan G.
    JOURNAL OF DIABETES AND METABOLIC DISORDERS, 2023, 22 (02) : 1779 - 1792
  • [26] Real time continuous glucose monitoring in high-risk people with insulin-requiring type 2 diabetes: A randomised controlled trial
    Lever, Claire S.
    Williman, Jonathan A.
    Boucsein, Alisa
    Watson, Antony
    Sampson, Rachael S.
    Sergel-Stringer, Oscar T.
    Keesing, Celeste
    Chepulis, Lynne
    Wheeler, Benjamin J.
    de Bock, Martin I.
    Paul, Ryan G.
    DIABETIC MEDICINE, 2024, 41 (08)
  • [27] Cost-Utility of Real-Time Continuous Glucose Monitoring versus Self-Monitoring of Blood Glucose in People with Insulin-Treated Type 2 Diabetes in Spain
    Merino-Torres, Juan Francisco
    Ilham, Sabrina
    Alshannaq, Hamza
    Pollock, Richard F.
    Ahmed, Waqas
    Norman, Gregory
    CLINICOECONOMICS AND OUTCOMES RESEARCH, 2024, 16 : 785 - 797
  • [28] The Influence of Real-Time Continuous Glucose Monitoring on Psychosocial Outcomes in Insulin-Using Type 2 Diabetes
    Soriano, Emily C.
    Polonsky, William H.
    JOURNAL OF DIABETES SCIENCE AND TECHNOLOGY, 2023, 17 (06): : 1614 - 1622
  • [29] Healthcare Utilization, Costs, and Adverse Events of Real-Time Continuous Glucose Monitoring versus Traditional Blood Glucose Monitoring Among US Adults with Type 1 Diabetes
    Wong, Benjamin
    Deng, Yalin
    Rascati, Karen L.
    JOURNAL OF DIABETES SCIENCE AND TECHNOLOGY, 2022, 16 (06): : 1393 - 1400
  • [30] Real-Time Continuous Glucose Monitoring in Gestational Diabetes: A Randomized Controlled Trial
    Lane, Andrew S.
    Mlynarczyk, Malgorzata A.
    de Veciana, Margarita
    Green, Lauren M.
    Baraki, Dana I.
    Abuhamad, Alfred Z.
    AMERICAN JOURNAL OF PERINATOLOGY, 2019, 36 (09) : 891 - 897