Continuous Glucose Monitoring and Time in Range: Association with Adverse Outcomes among People with Type 2 or Gestational Diabetes Mellitus

被引:12
作者
Bitar, Ghamar [1 ,4 ]
Cornthwaite, Joycelyn A. [1 ]
Sadek, Sandra [1 ]
Ghorayeb, Tala [1 ]
Daye, Nahla [1 ]
Nazeer, Sarah [1 ]
Ghafir, Danna [1 ]
Cornthwaite, John [2 ]
Chauhan, Suneet P. [1 ]
Sibai, Baha M. [1 ]
Bartal, Michal Fishel [1 ,3 ]
机构
[1] Univ Texas Hlth Sci Ctr Houston, McGovern Med Sch, Dept Obstet & Gynecol, Div Maternal Fetal Med, Houston, TX USA
[2] Rice Univ, Dept Earth Environm & Planetary Sci, Houston, TX USA
[3] Tel Aviv Univ, Sheba Med Ctr Tel Hashomer, Sackler Sch Med, Dept Obstet & Gynecol, Tel Aviv, Israel
[4] Univ Texas Hlth Sci Ctr Houston, Dept Obstet & Gynecol & Reprod Sci, Houston, TX 77030 USA
关键词
diabetes; pregnancy; continuous glucose monitoring; time in range; neonatal outcomes; maternal outcomes; PREGNANT-WOMEN; GLYCEMIC CONTROL; RECOMMENDATIONS; HYPOGLYCEMIA; MANAGEMENT;
D O I
10.1055/s-0043-1764208
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Objective Continuous glucose monitoring (CGM) has become available for women with type 2 diabetes mellitus (T2DM) or gestational diabetes mellitus (GDM) during pregnancy. The recommended time in range (TIR, blood glucose 70-140 mg/dL) and its correlation with adverse pregnancy outcomes in this group is unknown. Our aim was to compare maternal and neonatal outcomes in pregnant people with T2DM or GDM with average CGM TIR values > 70 versus < 70%.Study Design We conducted a retrospective cohort study of all individuals using CGM during pregnancy from January 2017 to June 2022. Individuals with type 1 diabetes mellitus, or those missing CGM or delivery data were excluded. Primary composite neonatal outcome included any of the following: large for gestational age, NICU admission, need for intravenous glucose, respiratory support, or neonatal death. Secondary outcomes included other maternal and neonatal outcomes. Regression models were used to estimate adjusted odds ratio (aOR) and 95% confidence interval (CI).Results During the study period, 141 individuals with diabetes utilized CGM during pregnancy, with 65 (46%) meeting inclusion criteria. Of the study population, 28 (43%) had TIR < 70% and 37 (57%) had TIR > 70%. Compared with those with TIR > 70%, the primary composite outcome occurred more frequently in neonates of individuals TIR < 70% (71.4 vs. 37.8%, aOR: 4.8, 95% CI: 1.6, 15.7). Furthermore, individuals with TIR < 70% were more likely to have hypertensive disorders (42.9 vs. 16.2%, OR: 3.9, 95% CI: 1.3, 13.0), preterm delivery (54 vs. 27%, OR: 3.1, 95% CI: 1.1, 9.1), and cesarean delivery (96.4 vs. 51.4%, OR: 4.6, 95% CI: 2.2, 15.1) compared with those with TIR > 70%.Conclusion Among people with T2DM or GDM who utilized CGM during pregnancy, 4 out 10 individuals had TIR < 70% and, compared with those with TIR > 70%, they had a higher likelihood of adverse neonatal and maternal outcomes.
引用
收藏
页码:e1370 / e1377
页数:8
相关论文
共 50 条
  • [1] Time in Range and Pregnancy Outcomes in People with Diabetes Using Continuous Glucose Monitoring
    Bartal, Michal Fishel
    Cornthwaite, Joycelyn A. Ashby A.
    Ghafir, Danna
    Ward, Clara
    Ortiz, Gladys
    Louis, Aleaha
    Cornthwaite, John
    Chauhan, Suneet S. P.
    Sibai, Baha M.
    AMERICAN JOURNAL OF PERINATOLOGY, 2023, 40 (05) : 461 - 466
  • [2] Practical Considerations for Using Continuous Glucose Monitoring in Patients with Gestational Diabetes Mellitus
    Castorino, Kristin
    Durnwald, Celeste
    Ehrenberg, Stacey
    Ehrhardt, Nicole
    Isaacs, Dianna
    Levy, Carol J.
    Valent, Amy M.
    JOURNAL OF WOMENS HEALTH, 2025, 34 (01) : 10 - 20
  • [3] Dietary composition and time in range in population with type 2 diabetes mellitus-exploring the association using continuous glucose monitoring device
    Deshmane, Aditi R.
    Muley, Arti S.
    ENDOCRINE, 2024, 85 (02) : 724 - 729
  • [4] Real-time continuous glucose monitoring improves postoperative glucose control in people with type 2 diabetes mellitus undergoing coronary artery bypass grafting: A randomized clinical trial
    Son, Heejun
    Sohn, Suk Ho
    Kim, Hyun Ah
    Choe, Hun Jee
    Lee, Hyunsuk
    Jung, Hye Seung
    Cho, Young Min
    Park, Kyong Soo
    Hwang, Ho Young
    Kwak, Soo Heon
    DIABETES OBESITY & METABOLISM, 2025, 27 (04) : 1836 - 1844
  • [5] Association Between Continuous Glucose Monitoring-Derived Time in Range, Other Core Metrics, and Albuminuria in Type 2 Diabetes
    Yoo, Jee Hee
    Choi, Min Sun
    Ahn, Jiyeon
    Park, Sung Woon
    Kim, Yejin
    Hur, Kyu Yeon
    Jin, Sang-Man
    Kim, Gyuri
    Kim, Jae Hyeon
    DIABETES TECHNOLOGY & THERAPEUTICS, 2020, 22 (10) : 768 - 776
  • [6] Continuous glucose monitoring-derived time in range and CV are associated with elevated risk of adverse kidney outcomes for patients with type 2 diabetes
    Zhang, Qin
    Xiao, Shucai
    Zou, Fang
    Jiao, Xiaojuan
    Shen, Yunfeng
    DIABETES & METABOLISM, 2025, 51 (02)
  • [7] Clinical Use of Continuous Glucose Monitoring in Adults with Type 2 Diabetes
    Carlson, Anders L.
    Mullen, Deborah M.
    Bergenstal, Richard M.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2017, 19 : S4 - S11
  • [8] The value of Continuous Glucose Monitoring and Self-Monitoring of Blood Glucose in patients with Gestational Diabetes Mellitus during Ramadan fasting
    Afandi, Bachar
    Hassanein, Mohamed
    Roubi, Sana
    Nagelkerke, Nico
    DIABETES RESEARCH AND CLINICAL PRACTICE, 2019, 151 : 260 - 264
  • [9] Continuous glucose monitoring targets in type 1 diabetes pregnancy: every 5% time in range matters
    Murphy, Helen R.
    DIABETOLOGIA, 2019, 62 (07) : 1123 - 1128
  • [10] Comparison of accuracy between flash glucose monitoring and continuous glucose monitoring in patients with type 2 diabetes mellitus undergoing hemodialysis
    Matoba, Kenta
    Hayashi, Akinori
    Shimizu, Naoya
    Moriguchi, Ibuki
    Kobayashi, Naoyuki
    Shichiri, Masayoshi
    JOURNAL OF DIABETES AND ITS COMPLICATIONS, 2020, 34 (11)