Development and validation of a liquid chromatography-tandem mass spectrometry method for the determination of temozolomide in mouse brain tissue

被引:0
|
作者
Kakarla, Raghavi [1 ]
Yacoub, Kimberly [1 ]
Bearden, Rebecca L. [1 ]
Zhou, Aimin [1 ]
Mukherjee, Sanjib [2 ]
Shan, Frank Y. [3 ]
Guo, Baochuan [1 ]
机构
[1] Cleveland State Univ, Dept Chem, 2121 Euclid Ave, Cleveland, OH 44115 USA
[2] Texas A&M Univ, Coll Med, Canc Ctr, Baylor Scott & White Hlth, Temple, TX 76508 USA
[3] Texas A&M Univ, Coll Med, Baylor Scott & White Hlth, Dept Pathol, Temple, TX 76508 USA
关键词
mass spectrometry; mouse brain; quantitation; temozolomide; validation;
D O I
10.1002/sscp.202200133
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Temozolomide is a Food and Drug Administration-approved anticancer drug that has poor drug delivery via oral or intravenous routes. A potential strategy to combat this problem is investigating alternative routes of administration, requiring quantitation of the drug in the brain tissues by liquid chromatography-mass spectrometry. However, current methods used to extract the drug from brain tissues resulted in poor recovery and substantial matrix effects. Herein, we reported a new two-step extraction method that involves the use of Proteinase K to lyse tumor tissues to efficiently release the drug, followed by ethanol protein precipitation. The extracts were then separated on a C18 column and analyzed in positive electrospray ionization, a multiple reaction monitoring mode of the triple quadrupole. We found this new method led to a recovery of 82% with negligible matrix effects. The method has been validated in accordance with Food and Drug Administration guidance for linearity, specificity, selectivity, accuracy, precision, carry-over, stability, and lower limit of quantitation. In conclusion, we have developed and validated a liquid chromatography-mass spectrometry method with a novel sample preparation method that was able to efficiently extract temozolomide from mouse brain tissue with high recovery.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Development and validation of sensitive liquid chromatography/tandem mass spectrometry method for quantification of bendamustine in mouse brain tissue
    He, Lei
    Grecula, John C.
    Ling, Yonghua
    Enzerra, Michael D.
    Ammirati, Mario
    Kendra, Kari
    Cavaliere, Robert
    Mayr, Nina
    McGregor, John
    Olencki, Thomas
    Mrozek, Ewa
    Matharbootham, Mani
    Oluigbo, Chima
    Phelps, Mitch A.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2012, 905 : 141 - 144
  • [2] Development and validation of a liquid chromatography-tandem mass spectrometry method for determination of ibuprofen in human plasma
    Puangpetch, Apichaya
    Limrungsikul, Anchalee
    Prommas, Santirhat
    Rukthong, Pattarawit
    Sukasem, Chonlaphat
    CLINICAL MASS SPECTROMETRY, 2020, 15 : 6 - 12
  • [3] A Liquid Chromatography-Tandem Mass Spectrometry Bioanalytical Method Development and Validation for the Determination of Pacritinib in Plasma
    Kumar, Mulamraju Aruna
    Bangaraiah, Pagala
    SEPARATION SCIENCE PLUS, 2024, 7 (12):
  • [4] Development and Validation of a Method for the Determination of Quinolones in Muscle and Eggs by Liquid Chromatography-Tandem Mass Spectrometry
    Loredana Annunziata
    Pierina Visciano
    Arianna Stramenga
    Maria Novella Colagrande
    Guido Campana
    Giampiero Scortichini
    Giacomo Migliorati
    Dario Compagnone
    Food Analytical Methods, 2016, 9 : 2308 - 2320
  • [5] Development and validation of a liquid chromatography-tandem mass spectrometry method for the determination of febuxostat in human plasma
    Wang, Haidong
    Deng, Pan
    Chen, Xiaoyan
    Guo, Lixia
    Zhong, Dafang
    BIOMEDICAL CHROMATOGRAPHY, 2013, 27 (01) : 34 - 38
  • [6] Development and validation of a liquid chromatography-tandem mass spectrometry method for the determination of goserelin in rabbit plasma
    Kim, Min Kyung
    Lee, Tae Ho
    Suh, Joon Hyuk
    Eom, Han Young
    Min, Jung Won
    Yeom, Hyesun
    Kim, Unyong
    Jung, Hyung Joon
    Cha, Kyung Hoi
    Choi, Yong Seok
    Youm, Jeong-Rok
    Han, Sang Beom
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2010, 878 (24): : 2235 - 2242
  • [7] Development and Validation of a Method for the Determination of Quinolones in Muscle and Eggs by Liquid Chromatography-Tandem Mass Spectrometry
    Annunziata, Loredana
    Visciano, Pierina
    Stramenga, Arianna
    Colagrande, Maria Novella
    Campana, Guido
    Scortichini, Giampiero
    Migliorati, Giacomo
    Compagnone, Dario
    FOOD ANALYTICAL METHODS, 2016, 9 (08) : 2308 - 2320
  • [8] Liquid chromatography-tandem mass spectrometry method for the determination of dye residues in aquaculture products: Development and validation
    Hurtaud-Pessel, D.
    Couedor, P.
    Verdon, E.
    JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (12) : 1632 - 1645
  • [9] Development and validation of a method for determination of corticosteroids in pig fat using liquid chromatography-tandem mass spectrometry
    Toelgyesi, Adam
    Sharma, Virender K.
    Fekete, Jeno
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2011, 879 (5-6): : 403 - 410
  • [10] Development and validation of a liquid chromatography-tandem mass spectrometry method for the determination of ε-acetamidocaproic acid in rat plasma
    Kim T.H.
    Choi Y.S.
    Choi Y.H.
    Kim Y.G.
    Toxicological Research, 2013, 29 (3) : 203 - 209