A case of supraventricular tachycardia misdiagnosis after dual-chamber implantable cardioverter defibrillator implantation with His bundle pacing

被引:0
作者
Sun, Xianchao [1 ]
Huang, Yue [1 ]
机构
[1] First Hosp Jiaxing, Jiaxing, Zhejiang, Peoples R China
关键词
atrial fibrillation; His bundle packing; implantable cardioverter defibrillator; supraventricular tachycardia; ventricular tachycardia; PREVENTION; RECIPIENTS; SURVIVAL;
D O I
10.1111/anec.13042
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The combined use of an implantable cardioverter defibrillator (ICD) and His bundle pacing (HBP) is believed to benefit patients with dilated cardiomyopathy (DCM) and atrial fibrillation but needs more guidance built on clinical experience. A patient who had an implanted dual-chamber ICD with HBP presented to our hospital with DCM and atrial fibrillation. In the present case, the criteria for differential diagnosis were set as "if all," which requires matching the morphological template, sudden onset, and interval stability. Ventricular tachycardia (VT) was misdiagnosed as supraventricular tachycardia due to morphological matching to sinus tachycardia. The misdiagnosis and mistaken VT treatment(ICD adaptive treatment) highlight the importance of personalized settings for differential diagnosis to avoid such a misdiagnosis or omission.
引用
收藏
页数:7
相关论文
共 41 条
  • [31] Reduced Risk for Inappropriate Implantable Cardioverter-Defibrillator Shocks With Dual-Chamber Therapy Compared With Single-Chamber Therapy Results of the Randomized OPTION Study
    Kolb, Christof
    Sturmer, Marcio
    Sick, Peter
    Reif, Sebastian
    Davy, Jean Marc
    Molon, Giulio
    Schwab, Joerg Otto
    Mantovani, Giuseppe
    Dan, Dan
    Lennerz, Carsten
    Borri-Brunetto, Alberto
    Babuty, Dominique
    JACC-HEART FAILURE, 2014, 2 (06) : 611 - 619
  • [32] Randomized pilot study of a new atrial-based minimal ventricular pacing mode in dual-chamber implantable cardioverter-defibrillators
    Sweeney, MO
    Shea, JB
    Fox, V
    Adler, S
    Nelson, L
    Mullen, TJ
    Belk, P
    Casavant, D
    Sheldon, T
    HEART RHYTHM, 2004, 1 (02) : 160 - 167
  • [33] Contribution of morphology discrimination algorithm for improving rhythm discrimination in slow and fast ventricular tachycardia zones in dual-chamber implantable cardioverter-defibrillators
    Boriani, Giuseppe
    Occhetta, Eraldo
    Cesario, Silvio
    Grossi, Stefano
    Marconi, Marco
    Speca, Giancarlo
    Silvestri, Paolo
    Biffi, Mauro
    Bortnik, Miriam
    Martignani, Cristian
    Branzi, Angelo
    EUROPACE, 2008, 10 (08): : 918 - 925
  • [34] Prognostic Significance of Nonsustained Ventricular Tachycardia Episodes Occurring Early After Implantable Cardioverter-Defibrillator Implantation Among Patients With Left Ventricular Dysfunction
    Jimenez-Candil, Javier
    Hernandez, Jesus
    Perdiguero, Pedro
    Martin, Ana
    Morinigo, Jose
    Bravo, Loreto
    Duran, Olga
    Sanchez, Pedro Luis
    AMERICAN JOURNAL OF CARDIOLOGY, 2016, 118 (10) : 1503 - 1510
  • [35] Increased base rate of atrial pacing for prevention of atrial fibrillation after implantation of a dual-chamber pacemaker: insights from the atrial overdrive pacing study
    Kantharia, Bharat K.
    Freedman, Roger A.
    Hoekenga, David
    Tomassoni, Gery
    Worley, Seth
    Sorrentino, Robert
    Steinhaus, David
    Wolkowicz, Joel M.
    Syed, Zaffer A.
    EUROPACE, 2007, 9 (11): : 1024 - 1030
  • [36] DIFFERENTIATION OF SINUS TACHYCARDIA FROM VENTRICULAR-TACHYCARDIA WITH 1/1-VENTRICULOATRIAL CONDUCTION IN DUAL-CHAMBER IMPLANTABLE CARDIOVERTER-DEFIBRILLATORS - FEASIBILITY OF A CRITERION BASED ON THE ATRIOVENTRICULAR INTERVAL
    LECARPENTIER, GL
    BAGA, JJ
    YANG, H
    STEINMAN, RT
    MEISSNER, MD
    LEHMANN, MH
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1994, 17 (11): : 1818 - 1831
  • [37] Implantable cardioverter-defibrillator programming after first occurrence of ventricular tachycardia in the Multicenter Automatic Defibrillator Implantation Trial-Reduce Inappropriate Therapy (MADIT-RIT)
    Aktas, Mehmet K.
    Bennett, Amanda L.
    Younis, Arwa
    Kutyifa, Valentina
    Polonsky, Bronislava
    McNitt, Scott
    Zareba, Wojciech
    Rosero, Spencer
    Goldenberg, Ilan
    HEART RHYTHM O2, 2020, 1 (02): : 77 - 82
  • [38] Dual Antiplatelet Therapy and Heparin "Bridging" Significantly Increase the Risk of Bleeding Complications After Pacemaker or Implantable Cardioverter-Defibrillator Device Implantation
    Tompkins, Christine
    Cheng, Alan
    Dalal, Darshan
    Brinker, Jeffrey A.
    Leng, Charles T.
    Marine, Joseph E.
    Nazarian, Saman
    Spragg, David D.
    Sinha, Sunil
    Halperin, Henry
    Tomaselli, Gordon F.
    Berger, Ronald D.
    Calkins, Hugh
    Henrikson, Charles A.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 55 (21) : 2376 - 2382
  • [39] Sudden death after inappropriate shocks of implantable cardioverter defibrillator in a catecholaminergic polymorphic ventricular tachycardia case with a novel RyR2 mutation
    Itoh, Hideki
    Murayama, Takashi
    Kurebayashi, Nagomi
    Ohno, Seiko
    Kobayashi, Takuya
    Fujii, Yusuke
    Watanabe, Masaya
    Ogawa, Haruo
    Anzai, Toshihisa
    Horie, Minoru
    JOURNAL OF ELECTROCARDIOLOGY, 2021, 69 : 111 - 118
  • [40] Magnetic Resonance Imaging Based Signal Intensity Mapping Predicts Appropriate Therapies After Prophylactic Ventricular Tachycardia Substrate Ablation in Patients With Previous Myocardial Infarction and Secondary Prevention Implantable Cardioverter-Defibrillator Implantation
    Bravo, Loreto
    Arenal, Angel
    Perez-David, Esther
    Avila, Pablo
    Rojas, Antonio
    Atienza, Felipe
    Gonzalez-Torrecilla, Esteban
    Datino, Tomas
    Ledesma-Carbayo, Maria
    Loughlin, Gerard
    Javier, Bermejo
    Fernandez-Aviles, Francisco
    CIRCULATION, 2013, 128 (22)