Hypothesis on the Decrement of the First Natural Frequencies of the Santa Maria Di Collemaggio Basilica from Three Years Monitoring: The Role of the CLT Roof

被引:5
作者
Aloisio, Angelo [1 ]
Cirella, Riccardo [1 ]
Antonacci, Elena [1 ]
Alaggio, Rocco [1 ]
机构
[1] Univ Aquila, Dept Civil Construct Architectural & Environm Eng, Via G Gronchi 18, I-67100 Laquila, Abruzzo, Italy
关键词
Automatic Operational Modal Analysis; Environmental effects; Structural Heath Monitoring; MOISTURE-CONTENT; HERITAGE STRUCTURES; DYNAMIC-BEHAVIOR; BELL TOWER; TIMBER; PERFORMANCE; PANELS;
D O I
10.1080/15583058.2021.2001115
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The long term dynamic monitoring of the Santa Maria di Collemaggio basilica revealed an unexpected trend of the first natural frequencies decreasing from their initial values estimated in 2018. The decrement of the natural frequency could originate from several factors. The structural system derives from the arrangement of four building materials: masonry (predominant), reinforced concrete (RC), timber and steel. Masonry is unlikely to suffer rapid decaying of their mechanical properties. Reinforced concrete (RC) and the embedded steel should not present decaying phenomena in the first years after built. Like- wise, the steel plates which connect the Cross-Laminated Timber (CLT) panels should not manifest a significant progression of corrosion in an indoor environment. Conversely, timber's physical and mechanical properties, such as swelling and shrinkage, density, modulus of elasticity, strength have a time-dependent response, even in the long-term. Likely, the decaying of the natural frequencies depends on the CLT roof's time-dependent be- haviour due to the potential modification of its mechanical properties and boundary conditions (interaction with the steel plates, e.g.). This paper presents selected results from the basilica's three-years continuous dynamic monitoring and discusses an elementary mechanical model representative of the dynamics transverse to the nave walls. The mechanical model described by a limited set of parameters drives the assessment of the CLT roof's possible role in causing the detected decrement of the natural frequencies.
引用
收藏
页码:955 / 969
页数:15
相关论文
共 46 条
  • [21] A radial distribution of moistures and tangential strains within a larch log cross section during radio-frequency/vacuum drying
    Kang W.
    Lee N.-H.
    Choi J.-H.
    [J]. Holz als Roh- und Werkstoff, 2004, 62 (1) : 59 - 63
  • [22] Temperature effects on static and dynamic behavior of Consoli Palace in Gubbio, Italy
    Kita, Alban
    Cavalagli, Nicola
    Ubertini, Filippo
    [J]. MECHANICAL SYSTEMS AND SIGNAL PROCESSING, 2019, 120 : 180 - 202
  • [23] Effects of sample size on swelling and shrinkage of Larix kaempferi and Cryptomeria japonica as determined by digital caliper, image analysis, and digital image correlation (DIC)
    Lee, So Sun
    Jeong, Gi Young
    [J]. HOLZFORSCHUNG, 2018, 72 (06) : 477 - 488
  • [24] Lepage R., 2012, THESIS U WATERLOO
  • [25] Lepage R., 2017, C 15 CAN C BUILD SCI, P17
  • [26] Longarini N., 2018, P INT MAS SOC C MIL
  • [27] The importance of structural monitoring as a diagnosis and control tool in the restoration process of heritage structures: A case study in Portugal
    Masciotta, Maria-Giovanna
    Ramos, Luis F.
    Lourenco, Paulo B.
    [J]. JOURNAL OF CULTURAL HERITAGE, 2017, 27 : 36 - 47
  • [28] A multidisciplinary approach to assess the health state of heritage structures: The case study of the Church of Monastery of Jeronimos in Lisbon
    Masciotta, Maria-Giovanna
    Roque, Joao C. A.
    Ramos, Luis F.
    Lourenco, Paulo B.
    [J]. CONSTRUCTION AND BUILDING MATERIALS, 2016, 116 : 169 - 187
  • [29] Hygrothermal performance of cross-laminated timber wall assemblies with built-in moisture: field measurements and simulations
    McClung, Ruth
    Ge, Hua
    Straube, John
    Wang, Jieying
    [J]. BUILDING AND ENVIRONMENT, 2014, 71 : 95 - 110
  • [30] More J. J., 1978, Proceedings of the Biennial Conference on numerical analysis, P105