Imputing missing sleep data from wearables with neural networks in real-world settings

被引:1
作者
Lee, Minki P. [1 ]
Hoang, Kien [2 ]
Park, Sungkyu [3 ]
Song, Yun Min [4 ,5 ]
Joo, Eun Yeon [6 ]
Chang, Won [7 ]
Kim, Jee Hyun [8 ]
Kim, Jae Kyoung [4 ,5 ]
机构
[1] Univ Michigan, Dept Math, Ann Arbor, MI USA
[2] Ecole Polytech Fed Lausanne, Inst Math, Lausanne, Switzerland
[3] Kangwon Natl Univ, Dept Artificial Intelligence Convergence, Chunchon, South Korea
[4] Korea Adv Inst Sci & Technol, Dept Math Sci, Daejeon, South Korea
[5] Inst for Basic Sci Korea, Biomed Math Grp, Daejeon, South Korea
[6] Sungkyunkwan Univ, Samsung Biomed Res Inst, Samsung Med Ctr, Dept Neurol,Neurosci Ctr,Sch Med, Seoul, South Korea
[7] Univ Cincinnati, Dept Math Sci, Cincinnati, OH 45221 USA
[8] Ewha Womans Univ, Coll Med, Seoul Hosp, Dept Neurol, Seoul, South Korea
基金
新加坡国家研究基金会;
关键词
wearable device; actigraphy; sleep-wake cycle; missing data imputation; machine learning; non-negative matrix factorization; SHIFT WORK; MULTIPLE IMPUTATION; CIRCADIAN-RHYTHMS; ACTIGRAPHY; INSOMNIA; APNEA;
D O I
10.1093/sleep/zsad266
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Sleep is a critical component of health and well-being but collecting and analyzing accurate longitudinal sleep data can be challenging, especially outside of laboratory settings. We propose a simple neural network model titled SOMNI (Sleep data restOration using Machine learning and Non-negative matrix factorIzation [NMF]) for imputing missing rest-activity data from actigraphy, which can enable clinicians to better handle missing data and monitor sleep-wake cycles of individuals with highly irregular sleep-wake patterns. The model consists of two hidden layers and uses NMF to capture hidden longitudinal sleep-wake patterns of individuals with disturbed sleep-wake cycles. Based on this, we develop two approaches: the individual approach imputes missing data based on the data from only one participant, while the global approach imputes missing data based on the data across multiple participants. Our models are tested with shift and non-shift workers' data from three independent hospitals. Both approaches can accurately impute missing data up to 24 hours of long dataset (>50 days) even for shift workers with extremely irregular sleep-wake patterns (AUC > 0.86). On the other hand, for short dataset (similar to 15 days), only the global model is accurate (AUC > 0.77). Our approach can be used to help clinicians monitor sleep-wake cycles of patients with sleep disorders outside of laboratory settings without relying on sleep diaries, ultimately improving sleep health outcomes.
引用
收藏
页数:17
相关论文
共 57 条
  • [1] The SBSM Guide to Actigraphy Monitoring: Clinical and Research Applications
    Ancoli-Israel, Sonia
    Martin, Jennifer L.
    Blackwell, Terri
    Buenaver, Luis
    Liu, Lianqi
    Meltzer, Lisa J.
    Sadeh, Avi
    Spira, Adam P.
    Taylor, Daniel J.
    [J]. BEHAVIORAL SLEEP MEDICINE, 2015, 13 : S4 - S38
  • [2] Feeling validated yet? A scoping review of the use of consumer-targeted wearable and mobile technology to measure and improve sleep
    Baron, Kelly Glazer
    Duffecy, Jennifer
    Berendsen, Mark A.
    Mason, Ivy Cheung
    Lattie, Emily G.
    Manalo, Natalie C.
    [J]. SLEEP MEDICINE REVIEWS, 2018, 40 : 151 - 159
  • [3] Automating sleep stage classification using wireless, wearable sensors
    Boe, Alexander J.
    Koch, Lori L. McGee
    O'Brien, Megan K.
    Shawen, Nicholas
    Rogers, John A.
    Lieber, Richard L.
    Reid, Kathryn J.
    Zee, Phyllis C.
    Jayaraman, Arun
    [J]. NPJ DIGITAL MEDICINE, 2019, 2 (01)
  • [4] Individual vulnerability to insomnia, excessive sleepiness and shift work disorder amongst healthcare shift workers. A systematic review
    Booker, Lauren A.
    Magee, Michelle
    Rajaratnam, Shantha M. W.
    Sletten, Tracey L.
    Howard, Mark E.
    [J]. SLEEP MEDICINE REVIEWS, 2018, 41 : 220 - 233
  • [5] A method for characterizing daily physiology from widely used wearables
    Bowman, Clark
    Huang, Yitong
    Walch, Olivia J.
    Fang, Yu
    Frank, Elena
    Tyler, Jonathan
    Mayer, Caleb
    Stockbridge, Christopher
    Goldstein, Cathy
    Sen, Srijan
    Forger, Daniel B.
    [J]. CELL REPORTS METHODS, 2021, 1 (04):
  • [6] The mobile sleep lab app: An open-source framework for mobile sleep assessment based on consumer-grade wearable devices
    Burgdorf, Andreas
    Guethe, Inga
    Jovanovic, Marko
    Kutafina, Ekaterina
    Kohlschein, Christian
    Bitsch, Jo Agila
    Jonas, Stephan M.
    [J]. COMPUTERS IN BIOLOGY AND MEDICINE, 2018, 103 : 8 - 16
  • [7] Imputation of missing data when measuring physical activity by accelerometry
    Catellier, DJ
    Hannan, PJ
    Murray, DM
    Addy, CL
    Conway, TL
    Yang, S
    Rice, JC
    [J]. MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2005, 37 (11) : S555 - S562
  • [8] The feasibility and reliability of actigraphy to monitor sleep in intensive care patients: an observational study
    Delaney, L. J.
    Litton, E.
    Melehan, K. L.
    Huang, H. -C. C.
    Lopez, V.
    Van Haren, F.
    [J]. CRITICAL CARE, 2021, 25 (01)
  • [9] Dong X., 2019, DAEIMP DENOISING AUT, P517
  • [10] Actigraphy-Based Assessment of Sleep Parameters
    Fekedulegn, Desta
    Andrew, Michael E.
    Shi, Mingming
    Violanti, John M.
    Knox, Sarah
    Innes, Kim E.
    [J]. ANNALS OF WORK EXPOSURES AND HEALTH, 2020, 64 (04) : 350 - 367