Stress-strain and fatigue life numerical evaluation of two different dental implants considering isotropic and anisotropic human jaw

被引:6
作者
De Stefano, Marco [1 ,4 ]
Lanza, Antonio [2 ]
Sbordone, Ludovico [3 ]
Ruggiero, Alessandro [1 ]
机构
[1] Univ Salerno, Dept Ind Engn, Fisciano, Italy
[2] Univ Salerno, Dept Med Surg & Dent Schola Med Salernitana, Baronissi, Italy
[3] Univ Molise, Dept Med & Hlth Sci, Campobasso, Italy
[4] Univ Salerno, Dept Ind Engn, Via Giovanni Paolo II,132, I-84084 Fisciano, Italy
关键词
Dental implants; human mandible; stress-strain; finite element method; fatigue; biotribology; FINITE-ELEMENT-ANALYSIS; BIOMECHANICAL ASPECTS; GAP FORMATION; BONE; SURVIVAL; FAILURE; TITANIUM; BEHAVIOR; DESIGN; PREDICTION;
D O I
10.1177/09544119231193879
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Dental prostheses are currently a valid solution for replacing potential missing tooth or edentulism clinical condition. Nevertheless, the oral cavity is a dynamic and complex system: occlusal loads, external agents, or other unpleasant events can impact on implants functionality and stability causing a future revision surgery. One of the failure origins is certainly the dynamic loading originated from daily oral activities like eating, chewing, and so on. The aim of this paper was to evaluate, by a numerical analysis based on Finite Elements Method (FEM), and to discuss in a comparative way, firstly, the stress-strain of two different adopted dental implants and, subsequently, their fatigue life according to common standard of calculations. For this investigation, the jawbone was modeled accounting for either isotropic or anisotropic behavior. It was composed of cortical and cancellous regions, considering it completely osseointegrated with the implants. The impact of implants' fixture design, loading conditions, and their effect on the mandible bone was finally investigated, on the basis of the achieved numerical results. Lastly, the life cycle of the investigated implants was estimated according to the well-established theories of Goodman, Soderberg, and Gerber by exploiting the outcomes obtained by the numerical simulations, providing interesting conclusions useful in the dental practice.
引用
收藏
页码:1190 / 1201
页数:12
相关论文
共 85 条
  • [51] Anisotropic elasticity of cortical and cancellous bone in the posterior mandible increases peri-implant stress and strain under oblique loading
    O'Mahony, AM
    Williams, JL
    Spencer, P
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2001, 12 (06) : 648 - 657
  • [52] Survival of dental implants at sites after implant failure: A systematic review
    Oh, Se-Lim
    Shiau, Harlan J.
    Reynolds, Mark A.
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2020, 123 (01) : 54 - 60
  • [53] Fracture and Fatigue of Dental Implants Fixtures and Abutments with a Novel Internal Connection Design: An In Vitro Pilot Study Comparing Three Different Dental Implant Systems
    On, Sung-Woon
    Yi, Sang-Min
    Park, In-Young
    Byun, Soo-Hwan
    Yang, Byoung-Eun
    [J]. JOURNAL OF FUNCTIONAL BIOMATERIALS, 2022, 13 (04)
  • [54] Parithimarkalaignan S, 2013, J Indian Prosthodont Soc, V13, P2, DOI 10.1007/s13191-013-0252-z
  • [55] Life prediction of different commercial dental implants as influence by uncertainties in their fatigue material properties and loading conditions
    Perez, M. A.
    [J]. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2012, 108 (03) : 1277 - 1286
  • [56] Fatigue of Narrow Dental Implants: Influence of the Hardening Method
    Perez, R. A.
    Gargallo, J.
    Altuna, P.
    Herrero-Climent, M.
    Gil, F. J.
    [J]. MATERIALS, 2020, 13 (06)
  • [57] Numerical prediction of peri-implant bone adaptation: Comparison of mechanical stimuli and sensitivity to modeling parameters
    Piccinini, Marco
    Cugnoni, Joel
    Botsis, John
    Ammann, Patrick
    Wiskott, Anselm
    [J]. MEDICAL ENGINEERING & PHYSICS, 2016, 38 (11) : 1348 - 1359
  • [58] Probability of Failure of Internal Hexagon and Morse Taper Implants with Different Bone Levels: A Mechanical Test and Probabilistic Fatigue
    Prados-Privado, Maria
    Gehrke, Sergio A.
    Rojo, Rosa
    Prados-Frutos, Juan Carlos
    [J]. INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2018, 33 (06) : 1266 - 1273
  • [59] Dental Implants Fatigue as a Possible Failure of Implantologic Treatment: The Importance of Randomness in Fatigue Behaviour
    Prados-Privado, Maria
    Carlos Prados-Frutos, Juan
    Manchon, Angel
    Rojo, Rosa
    Felice, Pietro
    Antonio Bea, Jose
    [J]. BIOMED RESEARCH INTERNATIONAL, 2015, 2015
  • [60] In vitro synchrotron-based radiography of micro-gap formation at the implant-abutment interface of two-piece dental implants
    Rack, A.
    Rack, T.
    Stiller, M.
    Riesemeier, H.
    Zabler, S.
    Nelson, K.
    [J]. JOURNAL OF SYNCHROTRON RADIATION, 2010, 17 : 289 - 294