Quantitative study on dose distribution of Freiburg flap for keloid high-dose-rate brachytherapy based on MatriXX

被引:0
作者
Ni, Jie [1 ]
Gan, Guanghui [1 ]
Xu, Xiaoting [1 ]
机构
[1] Soochow Univ, Affiliated Hosp 1, Radiat Therapy Ctr, 899 Pinghai St, Suzhou 215006, Jiangsu, Peoples R China
来源
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS | 2023年 / 24卷 / 09期
关键词
dose verification; HDR brachytherapy; MatriXX; AMERICAN BRACHYTHERAPY; TG-43; FORMALISM; DETECTOR ARRAY; DOSIMETRY; VERIFICATION;
D O I
10.1002/acm2.14118
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeTo quantify the dose distribution effect of insufficient scattering conditions in keloid HDR brachytherapy with Freiburg fFlap (FF) applicator. Materials and MethodsA phantom composed of FF applicator, MatriXX and solid water slices was designed and scanned for treatment planning. Bolus with different thicknesses were covered to offer different scatter conditions. Planar dose distributions were measured by MatriXX. The maximum value (Max), average value (Avg) and & gamma; passing rate (3 mm/3%) were evaluated by the software MyQA Platform. ResultsThe maximum and average doses measured by MatriXX were lower than the calculated values. The difference increased as field size decreased. The Max value, found at 0.86 cm level in the two tube case, was -20.0%, and the avg value was -11.9%. All the & gamma; values were less than 95%. This difference gradually decreased with increasing bolus thickness and the & gamma; values were significantly improved. ConclusionMatriXX could be used for dose verification of HDR brachytherapy with an FF applicator. When the FF applicator was applied for keloid, insufficient scattering conditions would cause an insufficient target dose. This difference could be reduced by covering the bolus with different thicknesses on the applicator. The smaller the field, the thicker the bolus required.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] High-dose-rate intraoperative brachytherapy for recurrent colorectal cancer
    Alektiar, KM
    Zelefsky, MJ
    Paty, PB
    Guillem, J
    Saltz, LB
    Cohen, AM
    Minsky, BD
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2000, 48 (01): : 219 - 226
  • [22] The clinical impact of removing rectal gas on high-dose-rate brachytherapy dose distributions for gynecologic cancers
    Vergalasova, Irina
    Ennis, Ronald D.
    Sayan, Mutlay
    Liu, Bo
    Yue, Ning J.
    Hathout, Lara
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2021, 22 (02): : 35 - 41
  • [23] Verification of SuperMC for Simulation of a High-Dose-Rate Brachytherapy Source
    Naeem, Hamza
    Wasaye, Muhammad Abdul
    Chen, Chaobin
    Zheng, Huaqing
    Hao, Lijuan
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2017, 70 (12) : 1077 - 1082
  • [24] Perioperative morbidity and mortality of high-dose-rate gynecologic brachytherapy
    Petereit, DG
    Sarkaria, JN
    Chappell, RJ
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1998, 42 (05): : 1025 - 1031
  • [25] Dose perturbation due to catheter materials in high-dose-rate interstitial 192Ir brachytherapy
    Gaudreault, Mathieu
    Reniers, Brigitte
    Landry, Guillaume
    Verhaegen, Frank
    Beaulieu, Luc
    BRACHYTHERAPY, 2014, 13 (06) : 627 - 631
  • [26] Radiochromic film-based quality assurance for CT-based high-dose-rate brachytherapy
    Asgharizadeh, Saeid
    Bekerat, Hamed
    Syme, Alasdair
    Aldelaijan, Saad
    DeBlois, Francois
    Te Vuong
    Evans, Michael
    Seuntjens, Jan
    Devic, Slobodan
    BRACHYTHERAPY, 2015, 14 (04) : 578 - 585
  • [27] American Brachytherapy Society consensus guidelines for high-dose-rate prostate brachytherapy
    Yamada, Yoshiya
    Rogers, Leland
    Demanes, D. Jeffrey
    Morton, Gerard
    Prestidges, Bradley R.
    Pouliot, Jean
    Cohen, Gil'ad N.
    Zaider, Marco
    Ghilezan, Mihai
    Hsu, I-Chow
    BRACHYTHERAPY, 2012, 11 (01) : 20 - 32
  • [28] Intraoperative high-dose-rate brachytherapy: An American Brachytherapy Society consensus report
    Lloyd, S.
    Alektiar, K. M.
    Naga, S.
    Huang, Y. J.
    Deufel, C. L.
    Mourtada, F.
    Gaffney, D. K.
    BRACHYTHERAPY, 2017, 16 (03) : 446 - 465
  • [29] Urethral dosimetry and toxicity with high-dose-rate interstitial brachytherapy for vaginal cancer
    Rajagopalan, Malolan S.
    Kannan, Neeta
    Kim, Hayeon
    Houser, Christopher J.
    Beriwal, Sushil
    BRACHYTHERAPY, 2013, 12 (03) : 248 - 253
  • [30] High-dose-rate brachytherapy boost for prostate cancer: Outcomes and genitourinary toxicity
    Bece, Andrej
    Patanjali, Nitya
    Jackson, Michael
    Whitaker, May
    Hruby, George
    BRACHYTHERAPY, 2015, 14 (05) : 670 - 676