Quantitative study on dose distribution of Freiburg flap for keloid high-dose-rate brachytherapy based on MatriXX

被引:0
作者
Ni, Jie [1 ]
Gan, Guanghui [1 ]
Xu, Xiaoting [1 ]
机构
[1] Soochow Univ, Affiliated Hosp 1, Radiat Therapy Ctr, 899 Pinghai St, Suzhou 215006, Jiangsu, Peoples R China
来源
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS | 2023年 / 24卷 / 09期
关键词
dose verification; HDR brachytherapy; MatriXX; AMERICAN BRACHYTHERAPY; TG-43; FORMALISM; DETECTOR ARRAY; DOSIMETRY; VERIFICATION;
D O I
10.1002/acm2.14118
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeTo quantify the dose distribution effect of insufficient scattering conditions in keloid HDR brachytherapy with Freiburg fFlap (FF) applicator. Materials and MethodsA phantom composed of FF applicator, MatriXX and solid water slices was designed and scanned for treatment planning. Bolus with different thicknesses were covered to offer different scatter conditions. Planar dose distributions were measured by MatriXX. The maximum value (Max), average value (Avg) and & gamma; passing rate (3 mm/3%) were evaluated by the software MyQA Platform. ResultsThe maximum and average doses measured by MatriXX were lower than the calculated values. The difference increased as field size decreased. The Max value, found at 0.86 cm level in the two tube case, was -20.0%, and the avg value was -11.9%. All the & gamma; values were less than 95%. This difference gradually decreased with increasing bolus thickness and the & gamma; values were significantly improved. ConclusionMatriXX could be used for dose verification of HDR brachytherapy with an FF applicator. When the FF applicator was applied for keloid, insufficient scattering conditions would cause an insufficient target dose. This difference could be reduced by covering the bolus with different thicknesses on the applicator. The smaller the field, the thicker the bolus required.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] A dose verification method for high-dose-rate brachytherapy treatment plans
    Kumar, Rajesh
    Sharma, S. D.
    Vijaykumar, C.
    Deshpande, Sudesh
    Sharma, P. K.
    Vandana, S.
    Philomena, A.
    Chilkulwar, Ravi H.
    JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2008, 4 (04) : 173 - 177
  • [2] IN VIVO TLD DOSE MEASUREMENTS IN CATHETER-BASED HIGH-DOSE-RATE BRACHYTHERAPY
    Adliene, Diana
    Jakstas, Karolis
    Urbonavicius, Benas Gabrielis
    RADIATION PROTECTION DOSIMETRY, 2015, 165 (1-4) : 477 - 481
  • [3] Dose comparison between TG-43-based calculatiOns and radiochromic film measurements of the Freiburg flap applicator used for high-dose-rate brachytherapy treatments of skin lesions
    Aldelaijan, Saad
    Bekerat, Hamed
    Buzurovic, Ivan
    Devlin, Phillip
    DeBlois, Francois
    Seuntjens, Jan
    Devic, Slobodan
    BRACHYTHERAPY, 2017, 16 (05) : 1065 - 1072
  • [4] Dosimetry comparison between TG-43 and Monte Carlo calculations using the Freiburg flap for skin high-dose-rate brachytherapy
    Vijande, Javier
    Ballester, Facundo
    Ouhib, Zoubir
    Granero, Domingo
    Carmen Pujades-Claumarchirant, M.
    Perez-Calatayud, Jose
    BRACHYTHERAPY, 2012, 11 (06) : 528 - 535
  • [5] A quality assurance tool for high-dose-rate brachytherapy
    Rickey, Daniel W.
    Sasaki, David
    Bews, Jeff
    MEDICAL PHYSICS, 2010, 37 (06) : 2525 - 2532
  • [6] High-dose-rate brachytherapy in uterine cervical carcinoma
    Patel, FD
    Rai, B
    Mallick, I
    Sharma, SC
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 62 (01): : 125 - 130
  • [7] High-dose-rate brachytherapy as monotherapy for prostate cancer
    Demanes, D. Jeffrey
    Ghilezan, Michel I.
    BRACHYTHERAPY, 2014, 13 (06) : 529 - 541
  • [8] High-dose-rate interstitial brachytherapy for gynecologic malignancies
    Beriwal, Sushil
    Bhatnagar, Ajay
    Heron, Dwight E.
    Selvaraj, Raj
    Mogus, Robert
    Kim, Hayeon
    Gerszten, Kristina
    Kelley, Joseph
    Edwards, Robert P.
    BRACHYTHERAPY, 2006, 5 (04) : 218 - 222
  • [9] A dose verification tool for high-dose-rate interstitial brachytherapy treatment planning in accelerated partial breast irradiation
    Marqa, Mohamad Feras
    Caudrelier, Jean-Michel
    Betrouni, Nacim
    BRACHYTHERAPY, 2012, 11 (05) : 359 - 368
  • [10] Biologic treatment planning for high-dose-rate brachytherapy
    Manning, MA
    Zwicker, RD
    Arthur, DW
    Arnfield, M
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 49 (03): : 839 - 845