An Orbitrap/Time-of-Flight Mass Spectrometer for Photofragment Ion Imaging and High-Resolution Mass Analysis of Native Macromolecular Assemblies

被引:5
|
作者
Mathew, Anjusha [1 ]
Giskes, Frans [1 ]
Lekkas, Alexandros [2 ]
Greisch, Jean-Francois [3 ,4 ,5 ]
Eijkel, Gert B. [1 ]
Anthony, Ian G. M. [1 ]
Fort, Kyle [6 ]
Heck, Albert J. R. [3 ,4 ,5 ]
Papanastasiou, Dimitris [2 ]
Makarov, Alexander A. [3 ,4 ,6 ]
Ellis, Shane R. [1 ,7 ,8 ]
Heeren, Ron M. A. [1 ]
机构
[1] Maastricht Univ, Maastricht MultiModal Mol Imaging Inst M4i, Div Imaging Mass Spectrometry IMS, NL-6229 ER Maastricht, Netherlands
[2] Demokritos NCSR, Fasmatech Sci & Technol, Athens 15310, Greece
[3] Univ Utrecht, Bijvoet Ctr Biomol Res, Biomol Mass Spectrometry & Prote, NL-3584 CH Utrecht, Netherlands
[4] Univ Utrecht, Utrecht Inst Pharmaceut Sci, NL-3584 CH Utrecht, Netherlands
[5] Netherlands Prote Ctr, NL-3584 CH Utrecht, Netherlands
[6] Thermo Fisher Sci Bremen GmbH, D-28199 Bremen, Germany
[7] Univ Wollongong, Mol Horizons, Wollongong, NSW 2522, Australia
[8] Univ Wollongong, Sch Chem & Mol Biosci, Wollongong, NSW 2522, Australia
基金
澳大利亚研究理事会;
关键词
macromolecular assemblies; Orbitrap mass spectrometry; orthogonal time-of-flight mass spectrometry; photofragmention imaging; Timepix detector; UV photodissociation; ULTRAVIOLET PHOTODISSOCIATION; TIME; DISSOCIATION; PROTEINS; RANGE; ACCURACY; POSITION; UVPD;
D O I
10.1021/jasms.3c00053
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We discuss the design, development, and evaluation ofan Orbitrap/time-of-flight(TOF) mass spectrometry (MS)-based instrument with integrated UV photodissociation(UVPD) and time/mass-to-charge ratio (m/z)-resolved imaging for the comprehensive study of the higher-ordermolecular structure of macromolecular assemblies (MMAs). A bespokeTOF analyzer has been coupled to the higher-energy collisional dissociationcell of an ultrahigh mass range hybrid quadrupole-Orbitrap MS. A 193nm excimer laser was employed to photofragment MMA ions. A combinationof microchannel plates (MCPs)-Timepix (TPX) quad and MCPs-phosphorscreen-TPX3CAM assemblies have been used as axial and orthogonal imagingdetectors, respectively. The instrument can operate in four differentmodes, where the UVPD-generated fragment ions from the native MMAions can be measured with high-mass resolution or imaged in a mass-resolvedmanner to reveal the relative positions of the UVPD fragments postdissociation.This information is intended to be utilized for retrieving higher-ordermolecular structural details that include the conformation, subunitstoichiometry, and molecular interactions as well as to understandthe dissociation dynamics of the MMAs in the gas phase.
引用
收藏
页码:1359 / 1371
页数:13
相关论文
共 50 条
  • [1] HIGH-RESOLUTION TIME-OF-FLIGHT MASS-SPECTROMETER
    BERGMANN, T
    MARTIN, TP
    SCHABER, H
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1989, 60 (04): : 792 - 793
  • [2] High Mass Resolution Multireflection Time-of-Flight Secondary Ion Mass Spectrometer
    Jiang, Jichun
    Hua, Lei
    Xie, Yuanyuan
    Cao, Yixue
    Wen, Yuxuan
    Chen, Ping
    Li, Haiyang
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2021, 32 (05) : 1196 - 1204
  • [3] Computer optimization for high-resolution time-of-flight mass spectrometer
    Even, U
    Dick, B
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2000, 71 (12): : 4415 - 4420
  • [4] High-resolution mass spectrometry of large molecules in a linear time-of-flight mass spectrometer
    Kinsel, G.R.
    Grundwuermer, J.M.
    Grotemeyer, J.
    Journal of the American Society for Mass Spectrometry, 1993, 4 (01):
  • [5] HIGH-RESOLUTION MASS-SPECTROMETRY IN A LINEAR TIME-OF-FLIGHT MASS-SPECTROMETER
    GRUNDWURMER, JM
    BONISCH, M
    KINSEL, GR
    GROTEMEYER, J
    SCHLAG, EW
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1994, 131 : 139 - 148
  • [6] Development and application of a high-resolution time-of-flight aerosol mass spectrometer
    Jimenez, Jose L.
    Decarlo, P.
    Kimmel, J. R.
    Huffman, J. A.
    Ulbrich, I.
    Dunlea, Edward
    Trimborn, A.
    Northway, M. J.
    Jayne, John T.
    Aiken, Allison C.
    Gonin, M.
    Fuhrer, K.
    Horvath, T.
    Docherty, Kenneth S.
    Worsnop, Douglas R.
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2007, 233 : 590 - 590
  • [7] A high-resolution time-of-flight mass spectrometer for the detection of ultracold molecules
    S.D. Kraft
    J. Mikosch
    P. Staanum
    J. Deiglmayr
    J. Lange
    A. Fioretti
    R. Wester
    M. Weidemüller
    Applied Physics B, 2007, 89 : 453 - 457
  • [8] A high-resolution time-of-flight mass spectrometer for the detection of ultracold molecules
    Kraft, S. D.
    Mikosch, J.
    Staanum, P.
    Deiglmayr, J.
    Lange, J.
    Fioretti, A.
    Wester, R.
    Weidemueller, M.
    APPLIED PHYSICS B-LASERS AND OPTICS, 2007, 89 (04): : 453 - 457
  • [9] An ion trap time-of-flight mass spectrometer with high mass resolution for cold trapped ion experiments
    Schmid, P. C.
    Greenberg, J.
    Miller, M. I.
    Loeffler, K.
    Lewandowski, H. J.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2017, 88 (12):
  • [10] MASS-REFLECTRON A NEW NONMAGNETIC TIME-OF-FLIGHT HIGH-RESOLUTION MASS-SPECTROMETER
    MAMYRIN, BA
    KARATAEV, VI
    SHMIKK, DV
    ZAGULIN, VA
    ZHURNAL EKSPERIMENTALNOI I TEORETICHESKOI FIZIKI, 1973, 64 (01): : 82 - 89