Quantitative flow ratio modulated by intracoronary optical coherence tomography for predicting physiological efficacy of percutaneous coronary intervention

被引:3
作者
Ding, Daixin [1 ,2 ,3 ]
Tu, Shengxian [3 ,7 ]
Li, Yingguang [4 ]
Li, Chunming [3 ]
Yu, Wei [3 ]
Liu, Xun [3 ]
Leone, Antonio Maria [5 ,6 ]
Aurigemma, Cristina [5 ]
Romagnoli, Enrico [5 ]
Vergallo, Rocco [5 ]
Trani, Carlo [5 ,6 ]
Wijns, William [1 ,2 ]
Burzotta, Francesco [5 ,6 ]
机构
[1] Univ Galway, Lambe Inst Translat Res, Smart Sensors Lab, Galway, Ireland
[2] Univ Galway, Lambe Inst Translat Res, CURAM, Galway, Ireland
[3] Shanghai Jiao Tong Univ, Biomed Instrument Inst, Sch Biomed Engn, Shanghai, Peoples R China
[4] Kunshan Ind Technol Res Inst, Int Smart Med Devices Innovat Ctr, Suzhou, Peoples R China
[5] Fdn Policlin Univ A Gemelli IRCCS, Inst Cardiol, Rome, Italy
[6] Univ Cattolica Sacro Cuore, Inst Cardiol, Rome, Italy
[7] Shanghai Jiao Tong Univ, Res Inst, Room 123,1954 Hua Shan Rd, Shanghai 200030, Peoples R China
基金
爱尔兰科学基金会;
关键词
coronary plaque; fractional flow reserve; optical coherence tomography; percutaneous coronary intervention; quantitative flow ratio; INTRAVASCULAR ULTRASOUND; DIAGNOSTIC-ACCURACY; STENT IMPLANTATION; RESERVE; STENOSIS; PCI; METAANALYSIS; MULTICENTER; ANGIOGRAPHY; IMMEDIATE;
D O I
10.1002/ccd.30681
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BackgroundThe combination of coronary imaging assessment and blood flow perturbation estimation has the potential to improve percutaneous coronary intervention (PCI) guidance. ObjectivesWe aimed to evaluate a novel method for fast computation of Murray law-based quantitative flow ratio (mu QFR) from coregistered optical coherence tomography (OCT) and angiography (OCT-modulated mu QFR, OCT-mu QFR) in predicting physiological efficacy of PCI. MethodsPatients treated by OCT-guided PCI in the OCT-arm of the Fractional Flow Reserve versus Optical Coherence Tomography to Guide RevasculariZAtion of Intermediate Coronary Stenoses trial (FORZA, NCT01824030) were included. Based on angiography and OCT before PCI, simulated residual OCT-mu QFR was computed by assuming full stent expansion to the intended-to-treat segment. Plaque composition was automatically characterized using a validated artificial intelligence algorithm. Actual post-PCI OCT-mu QFR pullback was computed based on coregistration of angiography and OCT acquired immediately after PCI. Suboptimal functional stenting result was defined as OCT-mu QFR <= 0.90. ResultsPaired simulated residual OCT-mu QFR and actual post-PCI OCT-mu QFR were obtained in 76 vessels from 74 patients. Simulated residual OCT-mu QFR showed good correlation (r = 0.80, p < 0.001), agreement (mean difference = -0.02 +/- 0.02, p < 0.001), and diagnostic concordance (79%, 95% confidence interval: 70%-88%) with actual post-PCI OCT-mu QFR. Actual post-PCI in-stent OCT-mu QFR had a median value of 0.02 and was associated with left anterior descending artery lesion location (beta = 0.38, p < 0.001), higher baseline total plaque burden (beta = 0.25, p = 0.031), and fibrous plaque volume (beta = 0.24, p = 0.026). ConclusionsThis study based on patients enrolled in a prospective OCT-guidance PCI trial shows that simulated residual OCT-mu QFR had good correlation, agreement, and diagnostic concordance with actual post-PCI OCT-mu QFR. In OCT-guided procedures, OCT-mu QFR in-stent pressure drop was low and was significantly predicted by pre-PCI vessel/plaque characteristics.
引用
收藏
页码:36 / 45
页数:10
相关论文
共 30 条
[1]   Optical coherence tomography-guided coronary stent implantation compared to angiography: a multicentre randomised trial in PCI - design and rationale of ILUMIEN IV: OPTIMAL PCI [J].
Ali, Ziad A. ;
Landmesser, Ulf ;
Galougahi, Keyvan Karimi ;
Maehara, Akiko ;
Matsumura, Mitsuaki ;
Shlofmitz, Richard A. ;
Guagliumi, Giulio ;
Price, Matthew J. ;
Hill, Jonathan M. ;
Akasaka, Takashi ;
Prati, Francesco ;
Bezerra, Hiram G. ;
Wijns, William ;
Mintz, Gary S. ;
Ben-Yehuda, Ori ;
McGreevy, Robert J. ;
Zhang, Zhen ;
Rapoza, Richard R. ;
West, Nick E. J. ;
Stone, Gregg W. .
EUROINTERVENTION, 2021, 16 (13) :1092-1099
[2]   Optical coherence tomography compared with intravascular ultrasound and with angiography to guide coronary stent implantation (ILUMIEN III: OPTIMIZE PCI): a randomised controlled trial [J].
Ali, Ziad A. ;
Maehara, Akiko ;
Genereux, Philippe ;
Shlofmitz, Richard A. ;
Fabbiocchi, Franco ;
Nazif, Tamim M. ;
Guagliumi, Giulio ;
Meraj, Perwaiz M. ;
Alfonso, Fernando ;
Samady, Habib ;
Akasaka, Takashi ;
Carlson, Eric B. ;
Leesar, Massoud A. ;
Matsumura, Mitsuaki ;
Ozan, Melek Ozgu ;
Mintz, Gary S. ;
Ben-Yehuda, Ori ;
Stone, Gregg W. .
LANCET, 2016, 388 (10060) :2618-2628
[3]   Fractional Flow Reserve or Optical Coherence Tomography to Guide Management of Angiographically Intermediate Coronary Stenosis A Single-Center Trial [J].
Burzotta, Francesco ;
Leone, Antonio Maria ;
Aurigemma, Cristina ;
Zambrano, Aniello ;
Zimbardo, Giuseppe ;
Arioti, Manfredi ;
Vergallo, Rocco ;
De Maria, Giovanni Luigi ;
Cerracchio, Emma ;
Romagnoli, Enrico ;
Trani, Carlo ;
Crea, Filippo .
JACC-CARDIOVASCULAR INTERVENTIONS, 2020, 13 (01) :49-58
[4]   Fractional flow reserve or optical coherence tomography guidance to revascularize intermediate coronary stenosis using angioplasty (FORZA) trial: study protocol for a randomized controlled trial [J].
Burzotta, Francesco ;
Leone, Antonio Maria ;
De Maria, Giovanni Luigi ;
Niccoli, Giampaolo ;
Coluccia, Valentina ;
Pirozzolo, Giancarlo ;
Saffioti, Silvia ;
Aurigemma, Cristina ;
Trani, Carlo ;
Crea, Filippo .
TRIALS, 2014, 15
[5]   Frequency-domain optical coherence tomography findings in patients with bifurcated lesions undergoing provisional stenting [J].
Burzotta, Francesco ;
Talarico, Giovanni Paolo ;
Trani, Carlo ;
De Maria, Giovanni Luigi ;
Pirozzolo, Giancarlo ;
Niccoli, Giampaolo ;
Leone, Antonio Maria ;
Saffioti, Silvia ;
Porto, Italo ;
Crea, Filippo .
EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2014, 15 (05) :547-555
[6]   Artificial intelligence and optical coherence tomography for the automatic characterisation of human atherosclerotic plaques [J].
Chu, Miao ;
Jia, Haibo ;
Gutierrez-Chico, Juan Luis ;
Maehara, Akiko ;
Ali, Ziad A. ;
Zeng, Xiaoling ;
He, Luping ;
Zhao, Chen ;
Matsumura, Mitsuaki ;
Wu, Peng ;
Zeng, Ming ;
Kubo, Takashi ;
Xu, Bo ;
Chen, Lianglong ;
Yu, Bo ;
Mintz, Gary S. ;
Wijns, William ;
Holm, Niels R. ;
Tu, Shengxian .
EUROINTERVENTION, 2021, 17 (01) :41-+
[7]   Quality of Life after PCI with Drug-Eluting Stents or Coronary-Artery Bypass Surgery [J].
Cohen, David J. ;
Van Hout, Ben ;
Serruys, Patrick W. ;
Mohr, Friedrich W. ;
Macaya, Carlos ;
den Heijer, Peter ;
Vrakking, M. M. ;
Wang, Kaijun ;
Mahoney, Elizabeth M. ;
Audi, Salma ;
Leadley, Katrin ;
Dawkins, Keith D. ;
Kappetein, A. Pieter .
NEW ENGLAND JOURNAL OF MEDICINE, 2011, 364 (11) :1016-1026
[8]  
Collison D., 2021, EUR HEART J, V42, P1
[9]   Intravascular ultrasound-guided optimized stent deployment - Immediate and 6 months clinical and angiographic results from the Multicenter Ultrasound Stenting in Coronaries Study (MUSIC Study) [J].
de Jaegere, P ;
Mudra, H ;
Figulla, H ;
Almagor, Y ;
Doucet, S ;
Penn, I ;
Colombo, A ;
Hamm, C ;
Bartorelli, A ;
Rothman, M ;
Nobuyoshi, M ;
Yamaguchi, T ;
Voudris, V ;
DiMario, C ;
Makovski, S ;
Hausmann, D ;
Rowe, S ;
Rabinovich, S ;
Sunamura, M ;
van Es, GA .
EUROPEAN HEART JOURNAL, 1998, 19 (08) :1214-1223
[10]   Optical flow ratio for assessing stenting result and physiological significance of residual disease [J].
Ding, Daixin ;
Yu, Wei ;
Tauzin, Helene ;
De Maria, Giovanni Luigi ;
Wu, Peng ;
Yang, Fan ;
Kotronias, Rafail A. ;
Terentes-Printzios, Dimitrios ;
Wolfrum, Mathias ;
Banning, Adrian P. ;
Meneveau, Nicolas ;
Wijns, William ;
Tu, Shengxian .
EUROINTERVENTION, 2021, 17 (12) :E989-+