Determination of olverembatinib in human plasma and cerebrospinal fluid by an LC-MS/MS method: Validation and clinical application

被引:3
|
作者
Xiang, Dong [1 ]
Zhao, Tinghui [1 ]
Wang, Jue [2 ]
Cao, Yang [2 ]
Yu, Qiuxia [2 ]
Liu, Lu [1 ]
Yu, Hengyi [1 ]
Li, Xiping [1 ]
Li, Ninghong [1 ]
Yi, Yang [3 ]
Gong, Xuepeng [1 ]
机构
[1] Huazhong Univ Sci & Technol, Tongji Med Coll, Dept Pharm, Tongji Hosp, Wuhan 430030, Peoples R China
[2] Huazhong Univ Sci & Technol, Tongji Med Coll, Dept Hematol, Tongji Hosp, Wuhan 430030, Peoples R China
[3] Huazhong Univ Sci & Technol, Tongji Med Coll, Dept Geriatr, Tongji Hosp, Wuhan 430030, Peoples R China
关键词
Olverembatinib; LC-MS; MS; Plasma; Cerebrospinal fluid; BCR-ABL KINASE; RESISTANCE; IMATINIB; INHIBITOR; URINE; MS;
D O I
10.1016/j.jpba.2023.115382
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A sensitive and robust LC-MS/MS method has been developed and validated for olverembatinib quantification in human plasma and cerebrospinal fluid (CSF). The method involved liquid-liquid extraction with methyl tertiary butyl ether for plasma pretreatment and precipitation enrichment with methanol for CSF pretreatment. Separation was achieved on the C18 column with gradient elutions of 10 mM ammonium formate in water and methanol-acetonitrile (50:50,v/v). Analyte detection was conducted by electrospray ionization (ESI) in a positive ion mode using multiple reaction monitoring (MRM). The m/z transitions were 533.4-*433.2 for olverembatinib and m/z 502.4-*394.2 for the internal standard (IS, Imatinib-d8). Calibration curves ranged from 0.500 to 50.0 ng/mL for plasma and from 0.0100 to 1.00 ng/mL for CSF. The intra- and inter-day precision and accuracy were < 15% for both plasma and CSF with four different quality control concentrations. The relative matrix effect was < 10% in plasma and artificial CSF. This method was successfully utilized for the measurement of olverembatinib concentrations in plasma and CSF from chronic myeloid leukemia patients.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] Establishment and validation of a LC-MS/MS method for the determination of anlotinib in human plasma: Application to therapeutic drug monitoring
    Yu, Mingjie
    Liang, Zaiming
    Xiong, Lirong
    Liu, Fang
    Cheng, Lin
    Jia, Changsheng
    Qi, Xiaowei
    Sun, Fengjun
    BIOMEDICAL CHROMATOGRAPHY, 2022, 36 (12)
  • [22] An LC-ESI-MS/MS method for determination of ondansetron in low-volume plasma and cerebrospinal fluid: Method development, validation, and clinical application
    Siemiatkowska, Anna
    Frey, Karen
    Gurba, Katharine N.
    Crock, Lara W.
    Haroutounian, Simon
    Kagan, Leonid
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2023, 235
  • [23] Application of LC-MS/MS method for determination of dihydroartemisin in human plasma in a pharmacokinetic study
    Wang, Huanhuan
    Yao, Xueting
    Wang, Teng
    Yan, Shuai
    Jiang, Ji
    Zhang, Fengchun
    Liu, Junfeng
    Gao, Duo
    Ma, Zhanguo
    Zhao, Qian
    Liu, Dongyang
    Hu, Pei
    BIOANALYSIS, 2020, 12 (22) : 1635 - 1646
  • [24] Development and Validation of LC-MS/MS Method for Determination of Ondansetron in rat Plasma and its Application
    Pang, Lingxia
    Wang, Qing
    Wang, Youpei
    Zheng, Meiqin
    Wu, Haiya
    Wang, Zhiyi
    LATIN AMERICAN JOURNAL OF PHARMACY, 2012, 31 (02): : 305 - 309
  • [25] Development of an LC-MS/MS-based method for quantitation of osimertinib in human plasma and cerebrospinal fluid
    Irie, Kei
    Nanjo, Shigeki
    Hata, Akito
    Yamasaki, Yuta
    Okada, Yutaka
    Katakami, Nobuyuki
    Fukushima, Shoji
    BIOANALYSIS, 2019, 11 (09) : 847 - 854
  • [26] Validation of LC-MS/MS methods for quantitative analysis of kynurenine pathway metabolites in human plasma and cerebrospinal fluid
    Khetarpal, Vinod
    Herbst, Todd
    Akhtar, Shahzad
    LaFayette, Amber
    Miller, Dennis
    Farnham, James
    Steege, Troy
    Miao, Zhixin
    Marks, Bryan
    Ledvina, Aaron
    Dominguez, Celia
    BIOANALYSIS, 2023, 15 (11) : 637 - 651
  • [27] Validation of LC-MS/MS method for determination of ginsenoside Rg1 in human plasma
    Kim, Yunjeong
    Han, Song-Hee
    Jeon, Ji-Young
    Hwang, Min-Ho
    Im, Yong-Jin
    Lee, Sun Young
    Chae, Soo-Wan
    Kim, Min-Gul
    ANALYTICAL SCIENCE AND TECHNOLOGY, 2013, 26 (04): : 221 - 227
  • [28] Development and Validation of LC-MS/MS Method for the Determination of 10-hydroxycarbazepine in Human Plasma
    Shi, Ling-min
    Li, Yu-mei
    Zeng, Wei-wei
    Chen, Min
    Qian, Jiang-chao
    Huang, Zhen
    Gong, Jian
    LATIN AMERICAN JOURNAL OF PHARMACY, 2015, 34 (04): : 646 - 651
  • [29] Development And Validation Of Sensitive LC-MS/MS Method For Determination Of Doravirine In Human Plasma Samples
    Bhadru, Banothu
    Rao, V. Venkata
    Vidyadhara, Suryadevara
    INTERNATIONAL JOURNAL OF LIFE SCIENCE AND PHARMA RESEARCH, 2020, 10 (03): : P29 - P35
  • [30] Development and validation of an LC-MS/MS method for the simultaneous determination of bedaquiline and rifabutin in human plasma
    Gray, Wesley A.
    Waldorf, Byron
    Rao, Manasa Geeta
    Stiles, Brenda L.
    Griffiss, J. McLeod
    Salata, Robert A.
    Blumer, Jeffrey L.
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2019, 176