Optimization of the distance between the vertical plates in the convective air heat exchanger

被引:4
作者
Ryms, Michal [1 ]
Tesch, Krzysztof [2 ]
Lewandowski, Witold M. [1 ]
机构
[1] Gdansk Univ Technol, Fac Chem, Dept Energy Convers & Storage, Narutowicza 11-12, PL-80233 Gdansk, Poland
[2] Gdansk Univ Technol, Inst Energy, Fac Mech Engn & Ship Technol, Narutowicza 11-12, PL-80233 Gdansk, Poland
关键词
Air heat exchanger; Free convection in air; Symmetrically heated vertical channel; Numerical velocity field reconstruction; Temperature field detection; Infrared imaging; Optimization; TURBULENT NATURAL-CONVECTION; SPECKLE PHOTOGRAPHY; FORCED-CONVECTION; MIXED CONVECTION; PARALLEL PLATES; BOUNDARY-LAYER; CHANNEL; FLOW; SURFACES; INTERFEROMETRY;
D O I
10.1016/j.ijthermalsci.2022.108064
中图分类号
O414.1 [热力学];
学科分类号
摘要
This paper examines the influence of the distance between vertical plates on the intensity of free convective heat transfer along with the optimization of this distance. Experimental tests were carried out for one model channel of such an heat exchanger with width s = 0.045, 0.085 and 0.18 m. This channel, open at the top and sides, was formed by two isothermal symmetrically heated parallel vertical plates of dimensions.. = 0.5 m and B = 0.25 m. The influence of the heating surface temperatures t(w) = 30, 40, 50, 55, 60 and 70 C-o on the convective temperature fields and velocity generated inside the channels was investigated. Directly measured temperature fields, as well as velocity fields measured indirectly using the NRP, enabled the thermodynamic parameters of the heat exchanger to be determined. Based on the temperature gradient distribution partial derivative T-w/partial derivative x on the wall, its average value was determined for each of the plates and for the entire channel, after which the heat flux Q(w) transferred from the plates was calculated. The heat flux transferred with the air.. and the efficiency eta=Q/Q(w) of heat transfer in the channel were determined using the balance method based on the average temperatures and air velocities at the inlet (t) over bar (bott) and (u) over bar (tn) and at the outlet (t) over bar (top) and (u) over bar (out) of the channel obtained from the temperature and velocity fields. A grid placed vertically in the channel, halfway across the panel width and perpendicular to the heating surfaces was used to detect the temperature field in air. The image and matrix of these temperatures were determined using a thermal imaging camera. The numerical reconstruction procedure (NRP) was used to determine the velocity field. For technical reasons and lack of time it was not possible to test more channels. Since three values of the width.. were insufficient to determine s(opt) it was decided to use numerical research. For this purpose, numerical results were compared with those obtained experimentally for the channels already tested. As the compliance verification was successful, further studies of the channels were continued numerically. As a result of optimizing the heat exchange intensification, optimal widths of a single channel S-opt = 0.035 m and.. channels s(0) = 0.0123 m, included in the heat exchanger, were obtained.
引用
收藏
页数:14
相关论文
共 87 条
[32]   HEAT-TRANSFER IN A CHANNEL BETWEEN VERTICAL ELECTRONIC-CIRCUIT BOARDS COOLED BY NATURAL AIR CONVECTION [J].
KATO, K ;
TAKARADA, T ;
MIYAZAKI, H ;
SATO, H ;
NAKAGAWA, N .
JOURNAL OF CHEMICAL ENGINEERING OF JAPAN, 1991, 24 (05) :568-574
[33]   Natural convective heat transfer coefficient - a review II. Surfaces in two- and three-dimensional enclosures [J].
Khalifa, AJN .
ENERGY CONVERSION AND MANAGEMENT, 2001, 42 (04) :505-517
[34]  
Kihm K., 1997, Advances in Heat Transfer, V30, P255
[35]  
KIHM KD, 1994, EXP FLUIDS, V17, P246, DOI 10.1007/BF00203043
[36]   Study on chimney effect on natural air cooling of electronic equipment under inclination [J].
Kitamura, Y ;
Ishizuka, M .
ITHERM 2004, VOL 1, 2004, :121-127
[37]   Combined experimental and numerical approaches to multi-mode heat transfer between vertical parallel plates [J].
Krishnan, AS ;
Premachandran, B ;
Balaji, C ;
Venkateshan, SP .
EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2004, 29 (01) :75-86
[38]   Holographic interferometry applied to coupled free convection and radiative transfer in a cavity containing a vertical plate between 290 and 650 K [J].
Lacona, E ;
Taine, J .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2001, 44 (19) :3755-3764
[39]   Natural convection in symmetrically heated vertical channels [J].
Lewandowski, Witold M. ;
Ryms, Michal ;
Denda, Hubert .
INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2018, 134 :530-540
[40]   Quantitative study of free convective heat losses from thermodynamic partitions using Thermal Imaging [J].
Lewandowski, Witold M. ;
Ryms, Michal ;
Denda, Hubert .
ENERGY AND BUILDINGS, 2018, 167 :370-383